511 research outputs found

    Shear effects in lateral piezoresponse force microscopy at 180∘^\circ ferroelectric domain walls

    Full text link
    In studies using piezoresponse force microscopy, we observe a non-zero lateral piezoresponse at 180∘^\circ domain walls in out-of-plane polarized, c-axis-oriented tetragonal ferroelectric Pb(Zr0.2_{0.2}Ti0.8_{0.8})O3_3 epitaxial thin films. We attribute these observations to a shear strain effect linked to the sign change of the d33d_{33} piezoelectric coefficient through the domain wall, in agreement with theoretical predictions. We show that in monoclinically distorted tetragonal BiFeO3_3 films, this effect is superimposed on the lateral piezoresponse due to actual in-plane polarization, and has to be taken into account in order to correctly interpret the ferroelectric domain configuration.Comment: 4 pages, 3 figure

    Population Pharmacokinetics and Pharmacodynamics Modeling of Torasemide and Furosemide After Oral Repeated Administration in Healthy Dogs

    Get PDF
    Torasemide is a loop diuretic licensed in dogs for cardiogenic pulmonary oedema. The aim of this pharmacokinetic-pharmacodynamic (PK/PD) study was to define an optimally effective dosage regimen based on preclinical data. In a first study, 5 dogs received once-daily oral torasemide (0, 0.1, 0.2, 0.4, 0.8 mg/kg/day) for 14 days. A second study compared once-daily oral torasemide (0, 0.1, 0.2, 0.3, 0.4 mg/kg/day) to twice-daily furosemide (1, 2, 4, 8 mg/kg/day). For all doses of the second study, 11 dogs received a first day of treatment, followed by a 3 day washout and resumed daily treatment for 10 days (until Day 14). Blood and urine were collected to measure urinary torasemide excretion and plasma torasemide concentrations and daily diuresis and natriuresis. Torasemide PK was linear. After rapid absorption (Tmax 0.5–1 h), 61% of the bioavailable torasemide was eliminated unchanged in urine. Diuresis and natriuresis observed with torasemide were similar to the ones obtained after furosemide (daily dose-ratios: 1/20 to 1/10). The average diuresis increased from baseline (220 ± 53 mL/day for 10 kg dogs) to 730 ±120 mL after the first torasemide administration and up to 1150 ± 252 mL after 10 administrations at the highest dose. At higher doses (≄0.3 mg/kg/day), daily diureses after 10 diuretic treatment-days were higher than Day 1 and variable between dogs; in contrast, diureses remained constant over time and less variable for doses up to 0.2 mg/kg/day. Natriuresis peaked after the first day and decreased dramatically after the 2nd treatment-day then stabilized to a value close to baseline, except for 0.4 mg/kg/day. Urinary torasemide excretion predicted pharmacodynamics better than plasma concentrations. The decrease in natriuresis observed was successfully modeled using a resistance mechanism; this is likely due to a reabsorption of sodium which did not seem however to affect the volume of urine excreted. For a daily target diuresis of 460 mL/dog/day in severe pulmonary oedema (net fluid loss 240 mL/dog/day), a computed dose of 0.26 mg/kg/day (3.5 mg/kg/day furosemide-equivalent) was selected for clinical studies. Due to high inter-individual variability in diureses at doses ≄0.3 mg/kg, higher doses should be limited to 3–5 days to avoid supra-clinical effects in high responders

    The DICE calibration project: design, characterization, and first results

    Full text link
    We describe the design, operation, and first results of a photometric calibration project, called DICE (Direct Illumination Calibration Experiment), aiming at achieving precise instrumental calibration of optical telescopes. The heart of DICE is an illumination device composed of 24 narrow-spectrum, high-intensity, light-emitting diodes (LED) chosen to cover the ultraviolet-to-near-infrared spectral range. It implements a point-like source placed at a finite distance from the telescope entrance pupil, yielding a flat field illumination that covers the entire field of view of the imager. The purpose of this system is to perform a lightweight routine monitoring of the imager passbands with a precision better than 5 per-mil on the relative passband normalisations and about 3{\AA} on the filter cutoff positions. The light source is calibrated on a spectrophotometric bench. As our fundamental metrology standard, we use a photodiode calibrated at NIST. The radiant intensity of each beam is mapped, and spectra are measured for each LED. All measurements are conducted at temperatures ranging from 0{\deg}C to 25{\deg}C in order to study the temperature dependence of the system. The photometric and spectroscopic measurements are combined into a model that predicts the spectral intensity of the source as a function of temperature. We find that the calibration beams are stable at the 10−410^{-4} level -- after taking the slight temperature dependence of the LED emission properties into account. We show that the spectral intensity of the source can be characterised with a precision of 3{\AA} in wavelength. In flux, we reach an accuracy of about 0.2-0.5% depending on how we understand the off-diagonal terms of the error budget affecting the calibration of the NIST photodiode. With a routine 60-mn calibration program, the apparatus is able to constrain the passbands at the targeted precision levels.Comment: 25 pages, 27 figures, accepted for publication in A&

    A nonlinear electro-thermal model for high power RF LDMOS transistors

    Get PDF
    A new nonlinear, charge-conservative, dynamic electro-thermal compact model for LDMOS RF power transistors is described in this paper. The transistor is characterized using pulsed I-V and S-parameter measurements, to ensure isothermal conditions. The intrinsic model current and charge sources are obtained by integration of the real and imaginary components, respectively, of the small-signal Y-parameters: this yields a charge-conservative model by design. A thermal sub-circuit is used to introduce dynamic thermal dependence, and thermal threshold voltage shift is built in. DC and large-signal validation of the model is presented. © 2008 IEEE

    The CLEO-III Ring Imaging Cherenkov Detector

    Get PDF
    The CLEO-III Detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout electronics. Results from our beam test at Fermilab are presented.Comment: Invited talk by R.J. Mountain at ``The 3rd International Workshop on Ring Imaging Cherenkov Detectors," a research workshop of the Israel Science Foundation, Ein-Gedi, Dead-Sea, Israel, Nov. 15-20, 1998, 14 pages, 9 figure

    Sarcopenia and cognitive impairment in elderly women: results from the EPIDOS cohort

    Get PDF
    BACKGROUND: common pathophysiological pathways are shared between age-related body composition changes and cognitive impairment. OBJECTIVE: evaluate whether current operative sarcopenia definitions are associated with cognition in community-dwelling older women. DESIGN: cross-sectional analyses. SUBJECTS: a total of 3,025 women aged 75 years and older. MEASUREMENTS: body composition (assessed by dual energy X-ray absorptiometry) and cognition (measured by short portable mental status questionnaire) were obtained in all participants. Multivariate logistic regression models assessed the association of six operative definitions of sarcopenia with cognitive impairment. Gait speed (GS, measured over a 6-meter track at usual pace) and handgrip strength (HG, measured by a hand-held dynamometer) were considered additional factors of interest. RESULTS: a total of 492 (16.3%) women were cognitively impaired. The prevalence of sarcopenia ranged from 3.3 to 18.8%. No sarcopenia definition was associated with cognitive impairment after controlling for potential confounders. To proof consistency, the analyses were performed using GS and HG, two well-established predictors of cognitive impairment. Low GS [odds ratio (OR) 2.42, 95% confidence interval (CI) 1.72-3.40] and low HG (OR: 1.81, 95% CI: 1.33-2.46) were associated with cognitive impairment. CONCLUSION: no significant association was evidenced between different operative sarcopenia definitions and cognitive impairment. The study suggests that the association between physical performance and cognitive impairment in not mediated by sarcopenia

    Artificially adaptive neuroanatomical specialisations in domestic pigeon (columba livia) breeds

    Get PDF
    The domestication of wild Rock Pigeons (Columba livia) has formed many breeds unique in behaviour, such as homing in homing pigeons and sexual displaying in cropper pigeons. Specialised behaviours are likely facilitated by concomitant changes in regional brain anatomy. Here we test how selection for behaviour is associated with neuroanatomical variation by comparing hippocampal formation (HF) and septal volume and neuron number across domestic and feral pigeons. We found significant neuroanatomical variation among breeds. Cropper pigeons have larger septum volumes, whereas homing pigeons have larger HF volumes and relatively smaller septum volumes. Furthermore, homing pigeons have significantly more HF neurons than most breeds, and twice as many HF neurons as feral pigeons, a finding we attribute to selection for homing. Cropper pigeons have more HF and septal neurons than most other breeds. These results suggest artificial selection for behaviour might be accompanied by significant changes in neuron number and density.NSERC CFI uLethbridg

    The OPERA experiment Target Tracker

    Get PDF
    The main task of the Target Tracker detector of the long baseline neutrino oscillation OPERA experiment is to locate in which of the target elementary constituents, the lead/emulsion bricks, the neutrino interactions have occurred and also to give calorimetric information about each event. The technology used consists in walls of two planes of plastic scintillator strips, one per transverse direction. Wavelength shifting fibres collect the light signal emitted by the scintillator strips and guide it to both ends where it is read by multi-anode photomultiplier tubes. All the elements used in the construction of this detector and its main characteristics are described.Comment: 25 pages, submitted to Nuclear Instrument and Method

    An extrinsic component parameter extraction method for high power RF LDMOS transistors

    Get PDF
    A new extrinsic network and extrinsic parameter extraction methodology is developed for high power RF LDMOS transistor modeling. This new method uses accurate manifold deembedding using electromagnetic simulation, and optimization of the extrinsic network parameter values over a broad frequency range. The new extrinsic network accommodates feedback effects which are observed in high power transistors. This improved methodology allows us to achieve a good agreement between measured and modeled S-parameters in the frequency range of 0.5 to 6 GHz for different bias conditions. Large-signal verification of this new model shows a very good match with measurements at 2.14 GHz. © 2008 IEEE

    General Principles for the Welfare of Animals in Production Systems: The Underlying Science and Its Application

    Get PDF
    In 2012, the World Organisation for Animal Health adopted 10 ‘General Principles for the Welfare of Animals in Livestock Production Systems’ to guide the development of animal welfare standards. The General Principles draw on half a century of scientific research relevant to animal welfare: (1) how genetic selection affects animal health, behaviour and temperament; (2) how the environment influences injuries and the transmission of diseases and parasites; (3) how the environment affects resting, movement and the performance of natural behaviour; (4) the management of groups to minimize conflict and allow positive social contact; (5) the effects of air quality, temperature and humidity on animal health and comfort; (6) ensuring access to feed and water suited to the animals’ needs and adaptations; (7) prevention and control of diseases and parasites, with humane euthanasia if treatment is not feasible or recovery is unlikely; (8) prevention and management of pain; (9) creation of positive human–animal relationships; and (10) ensuring adequate skill and knowledge among animal handlers. Research directed at animal welfare, drawing on animal behaviour, stress physiology, veterinary epidemiology and other fields, complements more established fields of animal and veterinary science and helps to create a more comprehensive scientific basis for animal care and management
    • 

    corecore