524 research outputs found

    Bimagnon studies in cuprates with Resonant Inelastic X-ray Scattering at the O K edge. II - The doping effect in La2-xSrxCuO4

    Full text link
    We present RIXS data at O K edge from La2-xSrxCuO4 vs. doping between x=0.10 and x=0.22 with attention to the magnetic excitations in the Mid-Infrared region. The sampling done by RIXS is the same as in the undoped cuprates provided the excitation is at the first pre-peak induced by doping. Note that this excitation energy is about 1.5 eV lower than that needed to see bimagnons in the parent compound. This approach allows the study of the upper region of the bimagnon continuum around 450 meV within about one third of the Brilluoin Zone around \Gamma. The results show the presence of damped bimagnons and of higher even order spin excitations with almost constant spectral weight at all the dopings explored here. The implications on high Tc studies are briefly addressed

    Large Binocular Telescope view of the atmosphere of GJ1214b

    Get PDF
    The atmospheric composition and vertical structure of the super-Earth GJ1214b has been a subject of debate since its discovery in 2009. Recent studies have indicated that high-altitude clouds might mask the lower layers. However, some data points that were gathered at different times and facilities do not fit this picture, probably because of a combination of stellar activity and systematic errors. We observed two transits of GJ1214b with the Large Binocular Camera, the dual-channel camera at the Large Binocular Telescope. For the first time, we simultaneously measured the relative planetary radius k=Rp/Rk=R_\mathrm{p}/R_\star at blue and red optical wavelengths (B+RB+R), thus constraining the Rayleigh scattering on GJ1214b after correcting for stellar activity effects. To the same purpose, a long-term photometric follow-up of the host star was carried out with WiFSIP at STELLA, revealing a rotational period that is significantly longer than previously reported. Our new unbiased estimates of kk yield a flat transmission spectrum extending to shorter wavelengths, thus confirming the cloudy atmosphere scenario for GJ1214b.Comment: 11 pages, 5 figures, 3 tables. Published in A&A. Minor changes to reflect the published versio

    Analysis of short-term blood pressure variability in pheochromocytoma/paraganglioma patients

    Get PDF
    Data on short-term blood pressure variability (BPV), which is a well-established cardiovascular prognostic tool, in pheochromocytoma and paraganglioma (PPGL) patients is still lack and conflicting. We retrospectively evaluated 23 PPGL patients referred to our unit from 2010 to 2019 to analyze 24 h ambulatory blood pressure monitoring (24-h ABPM)-derived markers of short-term BPV, before and after surgical treatment. PPGL diagnosis was assessed according to guidelines and confirmed by histologic examination. The 24-h ABPM-derived markers of short-term BPV included: circadian pressure rhythm; standard deviation (SD) and weighted SD (wSD) of 24-h, daytime, and night-time systolic and diastolic blood pressure (BP); average real variability (ARV) of 24-h, daytime, and night-time systolic and diastolic BP. 7 males and 16 females of 53 ± 18 years old were evaluated. After surgical resection of PPGL we found a significant decrease in 24-h systolic BP ARV (8.8 ± 1.6 vs. 7.6 ± 1.3 mmHg, p < 0.001), in 24-h diastolic BP ARV (7.5 ± 1.6 vs. 6.9 ± 1.4 mmHg, p = 0.031), and in wSD of 24-h diastolic BP (9.7 ± 2.0 vs 8.8 ± 2.1 mmHg, p = 0.050) comparing to baseline measurements. Moreover, baseline 24-h urinary metanephrines significantly correlated with wSD of both 24-h systolic and diastolic BP. Our study highlights as PPGL patients, after proper treatment, show a significant decrease in some short-term BPV markers, which might represent a further cardiovascular risk factor

    Practice Recommendations for Diagnosis and Treatment of the Most Common Forms of Secondary Hypertension

    Get PDF
    The vast majority of hypertensive patients are never sought for a cause of their high blood pressure, i.e. for a \u2018secondary\u2019 form of arterial hypertension. This under detection explains why only a tiny percentage of hypertensive patients are ultimately diagnosed with a secondary form of arterial hypertension. The prevalence of these forms is, therefore, markedly underestimated, although, they can involve as many as one-third of the cases among referred patients and up to half of those with difficult to treat hypertension. The early detection of a secondary form is crucial, because if diagnosed in a timely manner, these forms can be cured at long-term, and even when cure cannot be achieved, their diagnosis provides a better control of high blood pressure, and allows prevention of hypertension-mediated organ damage, and related cardiovascular complications. Enormous progress has been made in the understanding, diagnostic\ua0work-up, and management of secondary hypertension in the last decades. The\ua0aim of this minireview is, therefore, to provide updated concise information on the screening, diagnosis, and management of the most common forms, including primary aldosteronism, renovascular hypertension, pheochromocytoma and paraganglioma, Cushing\u2019s syndrome, and obstructive sleep apnea

    Hole-depletion of ladders in Sr14_{14}Cu24_{24}O41_{41} induced by correlation effects

    Full text link
    The hole distribution in Sr14_{14}Cu24_{24}O41_{41} is studied by low temperature polarization dependent O K Near-Edge X-ray Absorption Fine Structure measurements and state of the art electronic structure calculations that include core-hole and correlation effects in a mean-field approach. Contrary to all previous analysis, based on semi-empirical models, we show that correlations and antiferromagnetic ordering favor the strong chain hole-attraction. For the remaining small number of holes accommodated on ladders, leg-sites are preferred to rung-sites. The small hole affinity of rung-sites explains naturally the 1D - 2D cross-over in the phase diagram of (La,Y,Sr,Ca)14_{14}Cu24_{24}O41_{41}Comment: 6 pages, 8 figure

    Bimagnon studies in cuprates with Resonant Inelastic X-ray Scattering at the O K edge. I - An assessment on La2CuO4 and a comparison with the excitation at Cu L3 and Cu K edges

    Full text link
    We assess the capabilities of magnetic Resonant Inelastic X-ray Scattering (RIXS) at the O KK edge in undoped cuprates by taking La_{2}CuO_{4} as a benchmark case, based on a series of RIXS measurements that we present here. By combining the experimental results with basic theory we point out the fingerprints of bimagnon in the O KK edge RIXS spectra. These are a dominant peak around 450 meV, the almost complete absence of dispersion both with π\pi and σ\sigma polarization and the almost constant intensity vs. the transferred momentum with σ\sigma polarization. This behavior is quite different from Cu L3L_3 edge RIXS giving a strongly dispersing bimagnon tending to zero at the center of the Brillouin zone. This is clearly shown by RIXS measurements at the Cu L3L_3 edge that we present. The Cu L3L_3 bimagnon spectra and those at Cu KK edge - both from the literature and from our data - however, have the same shape. These similarities and differences are understood in terms of different sampling of the bimagnon continuum. This panorama points out the unique possibilities offered by O KK RIXS in the study of magnetic excitations in cuprates near the center of the BZ

    Analysis of time-profiles with in-beam PET monitoring in charged particle therapy

    Full text link
    Background: Treatment verification with PET imaging in charged particle therapy is conventionally done by comparing measurements of spatial distributions with Monte Carlo (MC) predictions. However, decay curves can provide additional independent information about the treatment and the irradiated tissue. Most studies performed so far focus on long time intervals. Here we investigate the reliability of MC predictions of space and time (decay rate) profiles shortly after irradiation, and we show how the decay rates can give an indication about the elements of which the phantom is made up. Methods and Materials: Various phantoms were irradiated in clinical and near-clinical conditions at the Cyclotron Centre of the Bronowice proton therapy centre. PET data were acquired with a planar 16x16 cm2^2 PET system. MC simulations of particle interactions and photon propagation in the phantoms were performed using the FLUKA code. The analysis included a comparison between experimental data and MC simulations of space and time profiles, as well as a fitting procedure to obtain the various isotope contributions in the phantoms. Results and conclusions: There was a good agreement between data and MC predictions in 1-dimensional space and decay rate distributions. The fractions of 11^{11}C, 15^{15}O and 10^{10}C that were obtained by fitting the decay rates with multiple simple exponentials generally agreed well with the MC expectations. We found a small excess of 10^{10}C in data compared to what was predicted in MC, which was clear especially in the PE phantom.Comment: 9 pages, 5 figures, 1 table. Proceedings of the 20th International Workshop on Radiation Imaging Detectors (iWorid2018), 24-28 June 2018, Sundsvall, Swede

    Detectors for the next-generation PET scanners

    Get PDF
    Next-generation PET scanners are expected to fulfill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultiplier (SiPM) matrices is proposed for the construction of a small animal PET system with depth of interaction capabilities. Measurements showing that SiPM matrices are highly ideal for PET applications, have been reported
    corecore