133 research outputs found

    Redox Proteomics and Platelet Activation: Understanding the Redox Proteome to Improve Platelet Quality for Transfusion.

    Get PDF
    Blood banks use pathogen inactivation (PI) technologies to increase the safety of platelet concentrates (PCs). The characteristics of PI-treated PCs slightly differ from those of untreated PCs, but the underlying reasons are not well understood. One possible cause is the generation of oxidative stress during the PI process. This is of great interest since reactive oxygen species (ROS) act as second messengers in platelet functions. Furthermore, there are links between protein oxidation and phosphorylation, another mechanism that is critical for cell regulation. Current research efforts focus on understanding the underlying mechanisms and identifying new target proteins. Proteomics technologies represent powerful tools for investigating signaling pathways involving ROS and post-translational modifications such as phosphorylation, while quantitative techniques enable the comparison of the platelet resting state versus the stimulated state. In particular, redox cysteine is a key player in platelet activation upon stimulation by different agonists. This review highlights the experiments that have provided insights into the roles of ROS in platelet function and the implications for platelet transfusion, and potentially in diseases such as inflammation and platelet hyperactivity. The review also describes the implication of redox mechanism in platelet storage considerations

    Oxygen in Red Blood Cell Concentrates: Influence of Donors' Characteristics and Blood Processing.

    Get PDF
    Objective: Unexpectedly wide distribution (<10 to >90%) of hemoglobin oxygen saturation (sO <sub>2</sub> ) within red cell concentrates (RCCs) has recently been observed. Causes of such variability are not yet completely explained whereas the roles of oxygen and oxidative lesions during the storage of RCCs are known. The objectives of the present study are to characterize sO <sub>2</sub> distribution in RCCs produced in a Swiss blood center and to investigate the influence of processing and donors' characteristics. Methods: The level of sO <sub>2</sub> was measured in 1701 leukocyte-depleted RCCs derived from whole blood donations in both top-bottom (TB; component filtered, SAGM) and top-top (TT; whole blood filtration, PAGGSM) RCCs. The sO <sub>2</sub> value was measured non-invasively through the PVC bag prior to storage by resonance Raman spectroscopy. Gender, age, blood type, hemoglobin level, and living altitude of donors, as well as process method and time-to-process were recorded. Results: Overall, the sO <sub>2</sub> exhibited a wide non-Gaussian distribution with a mean of 51.2 ± 18.5%. Use of top-top kits resulted in a 16% higher sO <sub>2</sub> (P < 0.0001) than with top-bottom ones. Waiting time before processing only had a modest impact, but the blood processing itself reduced the sO <sub>2</sub> by almost 12% (P < 0.0001). sO <sub>2</sub> was also significantly affected by some donors' characteristics. RCCs from men exhibited 25% higher sO <sub>2</sub> (P < 0.0001) than those donated by women. Multivariate analysis revealed that the apparent correlation observed with hemoglobin level and age was actually due to multicollinearity with the sex variable. Finally, we noticed no significant differences across blood type but found that altitude of residence was associated with the sO <sub>2</sub> (i.e., higher in higher living place). Conclusion: These data confirm wide sO <sub>2</sub> distribution in RCCs reported recently. The sO <sub>2</sub> was impacted by the processing and also by donors' characteristics such as the gender and the living altitude, but not by the hemoglobin level, blood group and donor age. This study provides new hints on the factors influencing red blood cells storage lesions, since they are known to be related to O <sub>2</sub> content within the bags, giving clues to better process and to better store RCCs and therefore potentially improve the efficacy of transfusion

    The clinical and biological impact of new pathogen inactivation technologies on platelet concentrates.

    Get PDF
    Since 1990, several techniques have been developed to photochemically inactivate pathogens in platelet concentrates, potentially leading to safer transfusion therapy. The three most common methods are amotosalen/UVA (INTERCEPT Blood System), riboflavin/UVA-UVB (MIRASOL PRT), and UVC (Theraflex-UV). We review the biology of pathogen inactivation methods, present their efficacy in reducing pathogens, discuss their impact on the functional aspects of treated platelets, and review clinical studies showing the clinical efficiency of the pathogen inactivation methods and their possible toxicity

    Sandwich mixer–reactor: influence of the diffusion coefficient and flow rate ratios

    Get PDF
    A sandwich mixer consists of mixing two solutions in a channel, one central laminar flow being sandwiched between two outer flow solutions. The present numerical study considers the convection– diffusion of two reacting species A and B, provided respectively by the two incoming solutions. The simulations show how the diffusion coefficient, flow rate and species concentration ratios influence, via the transversal diffusion length and reaction kinetics, the reaction extent at the end of the sandwich mixer. First, this extent can be enhanced up to 60% if the species with the lowest diffusion coefficient is located in the outer solutions where the flow velocity is small compared to that of the central part (higher residence time). Secondly, decreasing the outer flow rates (to confine the reaction close to the walls) and increasing the local concentration to keep the same flux ratio improve the extent by 300%. Comparison with a bi-lamination passive mixer, with an ideal mixer and an electro-osmotic driven flow mixer is presented. These conclusions are also demonstrated for consecutive reactions, showing an amplification of the effects described above. The results are also presented versus the residence time in the mixer–reactor to show the time window for which the gain is appreciable

    Multitrack electrospray chips

    Get PDF
    Multitrack electrospray chips (MTEC) were fabricated by UV-photoablation of polyethylene terephthalate (PET) substrates. They are composed of an array of up to six microchannels that are successively used as electrospray ionization (ESI) emitters for mass spectrometry (MS). There is no requirement for alignment of the different spraying microchannels with the mass spectrometer orifice. The MTEC is thus fixed in front of the mass spectrometer and the successive MS analyses are performed without moving the chip. The sequential electrospraying by successive application of an identical high voltage in each off-axis microchannel was evaluated for the fast screening of peptides and proteins. The counting of cysteines in peptides through chemical modification and the relative quantification of a peptide in two samples are presented herein as two original strategies based on this new analytical tool

    Electrospray Micromixer Chip for On-Line Derivatization and Kinetic Studies

    Get PDF
    An electrospray microchip for mass spectrometry comprising an integrated passive mixer to carry out on-chip chemical derivatizations is described. The microchip fabricated using UV-photoablation is composed of two microchannels linked together by a liquid junction. Downstream of this liquid junction, a mixing unit made of parallel oblique grooves is integrated to the microchannel in order to create flow perturbations. Several mixer designs are evaluated. The mixer efficiency is investigated both by fluorescence study and mass spectrometric monitoring of the tagging reaction of cysteinyl peptides with 1,4-benzoquinone. The comparisons with a microchip without a mixing unit and a kinetic model are used to assess the efficiency of the mixer showing tagging kinetics close to that of bulk reactions in an ideally mixed reactor. As an ultimate application, the electrospray micromixer is implemented in a LC-MS workflow. Online derivatization of albumin tryptic peptides after a reversed-phase separation and counting of their cysteines drastically enhance the protein identification

    Magnetic track array for efficient bead capture in microchannels

    Get PDF
    Magnetism-based microsystems, as those dedicated to immunoaffinity separations or (bio)chemical reactions, take benefit of the large surface area-to-volume ratio provided by the immobilized magnetic beads, thus increasing the sensitivity of the analysis. As the sensitivity is directly linked to the efficiency of the magnetic bead capture, this paper presents a simple method to enhance the capture in a microchannel. Considering a microchannel surrounded by two rectangular permanent magnets of different length (Lm=2, 5, 10 mm) placed in attraction, it is shown that the amount of trapped beads is limited by the magnetic forces mainly located at the magnet edges. To overcome this limitation, a polyethylene terephthalate (PET) microchip with an integrated magnetic track array has been prototyped by laser photo-ablation. The magnetic force is therefore distributed all along the magnet length. It results in a multi-plug bead capture, observed by microscope imaging, with a magnetic force value locally enhanced. The relative amount of beads, and so the specific binding surface for further immunoassays, presents a significant increase of 300% for the largest magnets. The influence of the track geometry and relative permeability on the magnetic force was studied by numerical simulations, for the microchip operating with 2-mm-long magnets

    Magnetic forces produced by rectangular permanent magnets in static microsystems

    Get PDF
    Finite element numerical simulations were carried out in 2D geometries to map the magnetic field and force distribution produced by rectangular permanent magnets as a function of their size and position with respect to a microchannel. A single magnet, two magnets placed in attraction and in repulsion have been considered. The goal of this work is to show where magnetic beads are preferentially captured in a microchannel. These simulations were qualitatively corroborated, in one geometrical case, by microscopic visualizations of magnetic bead plug formation in a capillary. The results show that the number of plugs is configuration dependent with: in attraction, one plug in the middle of the magnets; in repulsion, two plugs near the edges of the magnets; and with a single magnet, a plug close to the center of the magnet. The geometry of the magnets (h and l are the height and length of the magnets respectively) and their relative spacing s has a significant impact on the magnetic flux density. Its value inside a magnet increases with the h/l ratio. Consequently, bar magnets produce larger and more uniform values than flat magnets. The l/s ratio also influences the magnetic force value in the microchannel, both increasing concomitantly for all the configurations. In addition, a zero force zone in the middle appears in the attraction configuration as the l/s ratio increases, while with a single magnet, the number of maxima and minima goes from one to two, producing two focusing zones instead of only one
    corecore