52 research outputs found
Incremental Non-Rigid Structure-from-Motion with Unknown Focal Length
The perspective camera and the isometric surface prior have recently gathered
increased attention for Non-Rigid Structure-from-Motion (NRSfM). Despite the
recent progress, several challenges remain, particularly the computational
complexity and the unknown camera focal length. In this paper we present a
method for incremental Non-Rigid Structure-from-Motion (NRSfM) with the
perspective camera model and the isometric surface prior with unknown focal
length. In the template-based case, we provide a method to estimate four
parameters of the camera intrinsics. For the template-less scenario of NRSfM,
we propose a method to upgrade reconstructions obtained for one focal length to
another based on local rigidity and the so-called Maximum Depth Heuristics
(MDH). On its basis we propose a method to simultaneously recover the focal
length and the non-rigid shapes. We further solve the problem of incorporating
a large number of points and adding more views in MDH-based NRSfM and
efficiently solve them with Second-Order Cone Programming (SOCP). This does not
require any shape initialization and produces results orders of times faster
than many methods. We provide evaluations on standard sequences with
ground-truth and qualitative reconstructions on challenging YouTube videos.
These evaluations show that our method performs better in both speed and
accuracy than the state of the art.Comment: ECCV 201
A simple spectrophotometric method for the determination of methyldopa using p-chloranil in the presence of hydrogen peroxide
Estimation of climatological water deficit in an experimental watershed in the brazilian cerrado
Quality of life in liver transplant recipients and the influence of sociodemographic factors
Development and test of a small resistive fault current limiting device based on Hg, Re-1223 and Sm-123 ceramics
Migration of diethylhexyl phthalate from PVC bags into intravenous cyclosporine solutions
The migration of diethylhexyl phthalate (DEHP) from PVC bags into LVPS (0.9% NaCl) and LVPS with cyclosporine at concentrations of 2.5 and 0.5 mg/ml was studied. PVC bags were placed in contact with these solutions and stored at 25 1 degrees C. They were taken for analysis each 30 min during 6 h and after this period at each 1 h until 12 h of contact. Water was used as reference, and exposed and analyzed under the same conditions. After contact, the solutions were submitted to extraction with hexane and analyzed by GC-FID. The results showed that DEHP did not migrate into water and LVPS during all the time. Also, no measurable amount of DEHP was detected during the first 3 h of contact between the PVC bag and the diluted cyclosporine solution. However, the amount of released DEHP reached a detectable level after 4 It of contact, increased until 6 h, stabilized, and increased again after 9-10 h. The 12 h of contact showed the highest DEHP levels for both cyclosporine concentrations. The DEHP migrated was 0.02-0.08% of that present in the bag. (c) 2005 Elsevier B.V. All rights reserved
Computing Smooth Time Trajectories for Camera and Deformable Shape in Structure from Motion with Occlusion
- âŠ