8 research outputs found

    Acute retroperitoneal bleeding due to inferior mesenteric artery aneurysm: Case report

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Visceral artery aneurysms (VAA), although uncommon, are increasingly being detected. We describe a case of spontaneous retroperitoneal hemorrhage from a ruptured IMA aneurysm associated with stenosis of the superior mesenteric artery (SMA) and celiac trunk, successfully treated with surgery.</p> <p>Methods</p> <p>A 65-year-old man presented with abdominal pain and hypovolemic shock. Abdominal CT scan showed an aneurysm of the inferior mesenteric artery with retroperitoneal hematoma. In addition, an obstructive disease of the superior mesenteric artery and celiac axis was observed.</p> <p>Results</p> <p>Upon emergency laparotomy a ruptured inferior mesenteric artery aneurysm was detected. The aneurysm was excised and the artery reconstructed by end-to-end anastomosis.</p> <p>Conclusions</p> <p>This report discusses the etiology, presentation, diagnosis and case management of inferior mesenteric artery aneurysms.</p

    The value of metabolic imaging to predict tumour response after chemoradiation in locally advanced rectal cancer

    Get PDF
    Preliminary data of this work were presented by RCM and awarded at the 2009 Annual Meeting of the Spanish Society of Coloproctology (AECP) held in Barcelona.Background: We aim to investigate the possibility of using 18F-positron emission tomography/computer tomography (PET-CT) to predict the histopathologic response in locally advanced rectal cancer (LARC) treated with preoperative chemoradiation (CRT). Methods: The study included 50 patients with LARC treated with preoperative CRT. All patients were evaluated by PET-CT before and after CRT, and results were compared to histopathologic response quantified by tumour regression grade (patients with TRG 1-2 being defined as responders and patients with grade 3-5 as non-responders). Furthermore, the predictive value of metabolic imaging for pathologic complete response (ypCR) was investigated. Results: Responders and non-responders showed statistically significant differences according to Mandard's criteria for maximum standardized uptake value (SUVmax) before and after CRT with a specificity of 76,6% and a positive predictive value of 66,7%. Furthermore, SUVmax values after CRT were able to differentiate patients with ypCR with a sensitivity of 63% and a specificity of 74,4% (positive predictive value 41,2% and negative predictive value 87,9%); This rather low sensitivity and specificity determined that PET-CT was only able to distinguish 7 cases of ypCR from a total of 11 patients. Conclusions: We conclude that 18-F PET-CT performed five to seven weeks after the end of CRT can visualise functional tumour response in LARC. In contrast, metabolic imaging with 18-F PET-CT is not able to predict patients with ypCR accuratelyFounded by the Fundación Investigación Mutua Madrileña. We are indebted to M. Expósito Ruiz for statistical support. and to J-L Marín Aznar for pathologic analysisYe

    The value of metabolic imaging to predict tumour response after chemoradiation in locally advanced rectal cancer

    No full text
    Abstract Background We aim to investigate the possibility of using 18F-positron emission tomography/computer tomography (PET-CT) to predict the histopathologic response in locally advanced rectal cancer (LARC) treated with preoperative chemoradiation (CRT). Methods The study included 50 patients with LARC treated with preoperative CRT. All patients were evaluated by PET-CT before and after CRT, and results were compared to histopathologic response quantified by tumour regression grade (patients with TRG 1-2 being defined as responders and patients with grade 3-5 as non-responders). Furthermore, the predictive value of metabolic imaging for pathologic complete response (ypCR) was investigated. Results Responders and non-responders showed statistically significant differences according to Mandard's criteria for maximum standardized uptake value (SUVmax) before and after CRT with a specificity of 76,6% and a positive predictive value of 66,7%. Furthermore, SUVmax values after CRT were able to differentiate patients with ypCR with a sensitivity of 63% and a specificity of 74,4% (positive predictive value 41,2% and negative predictive value 87,9%); This rather low sensitivity and specificity determined that PET-CT was only able to distinguish 7 cases of ypCR from a total of 11 patients. Conclusions We conclude that 18-F PET-CT performed five to seven weeks after the end of CRT can visualise functional tumour response in LARC. In contrast, metabolic imaging with 18-F PET-CT is not able to predict patients with ypCR accurately.</p

    Search for supersymmetry in events with large missing transverse momentum, jets, and at least one tau lepton in 20 fb−1 of √s= 8 TeV proton-proton collision data with the ATLAS detector

    No full text
    © 2014, The Author(s). A search for supersymmetry (SUSY) in events with large missing transverse momentum, jets, at least one hadronically decaying tau lepton and zero or one additional light leptons (electron/muon), has been performed using 20.3fb−1of proton-proton collision data at √ s= 8 TeV recorded with the ATLAS detector at the Large Hadron Collider. No excess above the Standard Model background expectation is observed in the various signal regions and 95% confidence level upper limits on the visible cross section for new phenomena are set. The results of the analysis are interpreted in several SUSY scenarios, significantly extending previous limits obtained in the same final states. In the framework of minimal gauge-mediated SUSY breaking models, values of the SUSY breaking scale Λ below 63 TeV are excluded, independently of tan β. Exclusion limits are also derived for an mSUGRA/CMSSM model, in both the R-parity-conserving and R-parity-violating case. A further interpretation is presented in a framework of natural gauge mediation, in which the gluino is assumed to be the only light coloured sparticle and gluino masses below 1090 GeV are excluded
    corecore