10 research outputs found

    Does preoperative analysis of intrahepatic venous anastomoses improve the surgeon's intraoperative decision making? Pilot data from a case report

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Three-dimensional (3D) visualization is thought to improve the anatomical understanding of clinicians, thus improving patient safety.</p> <p>Case presentation</p> <p>A 58-year-old male was admitted to our hospital in April 2007 with a suspected metastasis of a sigmoid cancer in the Couinaud segment (CS) 7. The anatomical situation of this patient was analyzed using both a CT scan and 3D images. The initial CT scan revealed that the proximal part of the middle hepatic vein was completely missing and the metastasis in the CS 7 was closely attached to the right hepatic vein. After analyzing additional 3D images, it became clear that due to the close proximity of metastasis and right hepatic vein, the resection of the right hepatic vein was inevitable. Based on this 3D analysis, it was decided to perform a right-sided hemihepatectomy. In this case report, 3D visualization resulted in a faster and clearer understanding of the unique anatomical situation in a patient with complicated liver anatomy than transversal CT images.</p> <p>Conclusion</p> <p>The here presented data shows for the first time 3D visualization of intravenous anastomoses in the human liver. The information offered by 3D visualization is not redundant but rather serves as a true source of additional information, indicating the potential benefit of 3D visualization in surgical operation planning.</p

    Coronary CT angiography derived fractional flow reserve: Methodology and evaluation of a point of care algorithm

    No full text
    Background: Recently several publications described the diagnostic value of coronary CT angiography (coronary CTA) derived fractional flow reserve (CTA-FFR). For a recently introduced on-site CTA-FFR application, detailed methodology and factors potentially affecting performance have not yet been described. Objective: To provide a methodological background for an on-site CTA-FFR application and evaluate the effect of patient and acquisition characteristics. Methods: The on-site CTA-FFR application utilized a reduced-order hybrid model applying pressure drop models within stenotic regions. In 116 patients and 203 vessels the diagnostic performance of CTA-FFR was investigated using invasive FFR measurements as a reference. The effect of several potentially relevant factors on CTA-FFR was investigated. Results: 90 vessels (44%) had a hemodynamically relevant stenosis according to invasive FFR (threshold <= 0.80). The overall vessel-based sensitivity, specificity and accuracy of CTA-FFR were 88% (CI 95%: 79 -94%), 65% (55-73%) and 75% (69-81%). The specificity was significantly lower in the presence of misalignment artifacts (25%, CI: 6-57%). A non-significant reduction in specificity from 74% (60-85%) to 48% (26-70%) was found for higher coronary artery calcium scores. Left ventricular mass, diabetes mellitus and large vessel size increased the discrepancy between invasive FFR and CTA-FFR values. Conclusions: On-site calculation of CTA-FFR can identify hemodynamically significant CAD with an overall per-vessel accuracy of 75% in comparison to invasive FFR. The diagnostic performance of CTA-FFR is negatively affected by misalignment artifacts. CTA-FFR is potentially affected by left ventricular mass, diabetes mellitus and vessel size. (C) 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved
    corecore