22 research outputs found
New insights into the physics of inertial microfluidics in curved microchannels. I. Relaxing the fixed inflection point assumption.
Inertial microfluidics represents a powerful new tool for accurately positioning cells and microparticles within fluids for a variety of biomedical, clinical, and industrial applications. In spite of enormous advancements in the science and design of these devices, particularly in curved microfluidic channels, contradictory experimental results have confounded researchers and limited progress. Thus, at present, a complete theory which describes the underlying physics is lacking. We propose that this bottleneck is due to one simple mistaken assumption-the locations of inflection points of the Dean velocity profile in curved microchannels are not fixed, but can actually shift with the flow rate. Herein, we propose that the dynamic distance (δ) between the real equilibrium positions and their nearest inflection points can clearly explain several (previously) unexplained phenomena in inertial microfluidic systems. More interestingly, we found that this parameter, δ, is a function of several geometric and operational parameters, all of which are investigated (in detail) here with a series of experiments and simulations of different spiral microchannels. This key piece of understanding is expected to open the door for researchers to develop new and more effective inertial microfluidic designs
Quantum statistics and blockade of phonon and photon in a dissipative quadratically coupled optomechanical system
There exists a tight relation between single-phonon and -photon source devices with the phonon and photon blockade implementations. These sources possess significant practical applications in quantum information processing and engineering. In this paper, we present a scheme to investigate the quantum statistics, as well as the phonon and photon blockade phenomena in an optomechanical system with quadratic coupling whose cavity has a moving membrane that is placed in the node (or antinode) of the optomechanical cavity. Strong nonlinear interaction between the optical and mechanical modes is induced by a driving field through radiation pressure. Also, the effective coupling strength can be adjusted by controlling the amplitude of an external pump field. Using the obtained effective Hamiltonian, we examine the steady state equal-time second-order correlation function via solving the Lindblad master equation which includes optical and mechanical dissipation sources. Our numerical results show that, with suitable adjustment of the system feasible parameters, we can achieve sub-Poissonian behavior, and as a result, an acceptable degree of phonon blockade. While using the same parameters, for the photon blockade, we arrive at a moderate or even weakly degree of the blockade. It should be emphasized that, as is shown, it is possible to make the scenario vice versa. By this, we mean that one can use a set of parameters by which a high (low) degree of photon (phonon) blockade is occurred. Moreover, we present a set of parameters for an optimal simultaneous occurrence of moderate phonon and photon blockade
Selective separation of microalgae cells using inertial microfluidics
© 2017 Elsevier Ltd Microalgae represent the most promising new source of biomass for the world's growing demands. However, the biomass productivity and quality is significantly decreased by the presence of bacteria or other invading microalgae species in the cultures. We therefore report a low-cost spiral-microchannel that can effectively separate and purify Tetraselmis suecica (lipid-rich microalgae) cultures from Phaeodactylum tricornutum (invasive diatom). Fluorescent polystyrene-microbeads of 6 μm and 10 μm diameters were first used as surrogate particles to optimize the microchannel design by mimicking the microalgae cell behaviour. Using the optimum flowrate, up to 95% of the P. tricornutum cells were separated from the culture without affecting the cell viability. This study shows, for the first time, the potential of inertial microfluidics to sort microalgae species with minimal size difference. Additionally, this approach can also be applied as a pre-sorting technique for water quality analysis
Effect of a family-centered clinical intervention on the anxiety of family members of the patients hospitalized in critical care units
Background and Objective: Hospitalization of patients in the intensive care units frequently results in anxiety of the family members. This study was performed to investigate the effect of a family-centered clinical intervention on the anxiety of family members of the patients hospitalized in intensive care units.
Methods: In this clinical trail study, eighty family members of the patients hospitalized in the intensive care units were randomly divided into interventional and control groups, respectively. In the interventional group, the family members were allowed to be present at the bedside from the second till the sixth day.The participant's level of anxiety was assessed in the second and the sixth day of patient's hospitalization using hospital anxiety and depression scale. Oral information about the equipment and the regulations and, a daily information card consisting of treatment and care activities, vital signs and patient's level of consciousness was delivered to the participants and their questions were answered.
Results: In the the sixth day, there was a significant difference between the mean anxiety scores in the intervention (11±3.22) and control group (7.05±3.44) (P<0.05). Also, the frequncey of anxiety in the interventional group (56%) was significantly higher than the control group with 15% (P<0.05). The odds ratio for anxiety in sons/daughters was lower than other family members in the sixth day (P<0.05).
Conclusion: Providing information, presence at the bedside and participation in the care of their patient increase the anxiety of family members in the first week of patient hospitalization in the intensive care unit
Multiplexing slanted spiral microchannels for ultra-fast blood plasma separation.
Blood and blood products are critical components of health care. Blood components perform distinct functions in the human body and thus the ability to efficiently fractionate blood into its individual components (i.e., plasma and cellular components) is of utmost importance for therapeutic and diagnostic purposes. Although conventional approaches like centrifugation and membrane filtration for blood processing have been successful in generating relatively pure fractions, they are largely limited by factors such as the required blood sample volume, component purity, clogging, processing time and operation efficiency. In this work, we developed a high-throughput inertial microfluidic system for cell focusing and blood plasma separation from small to large volume blood samples (1-100 mL). Initially, polystyrene beads and blood cells were used to investigate the inertial focusing performance of a single slanted spiral microchannel as a function of particle size, flow rate, and blood cell concentration. Afterwards, blood plasma separation was conducted using an optimised spiral microchannel with relatively large dimensions. It was found that the reject ratio of the slanted spiral channel is close to 100% for blood samples with haematocrit (HCT) values of 0.5% and 1% under an optimal flow rate of 1.5 mL min(-1). Finally, through a unique multiplexing approach, we built a high-throughput system consisting of 16 spiral channels connected together, which can process diluted samples with a total flow rate as high as 24 mL min(-1). The proposed multiplexed system can surmount the shortcomings of previously reported microfluidic systems for plasma separation and cell sorting in terms of throughput, yield and operation efficiency
An easily fabricated three-dimensional threaded lemniscate-shaped micromixer for a wide range of flow rates
Mixing fluid samples or reactants is a paramount function in the fields of micro total analysis system (μTAS) and microchemical processing. However, rapid and efficient fluid mixing is difficult to achieve inside microchannels because of the difficulty of diffusive mass transfer in the laminar regime of the typical microfluidic flows. It has been well recorded that the mixing efficiency can be boosted by migrating from two-dimensional (2D) to three-dimensional (3D) geometries. Although several 3D chaotic mixers have been designed, most of them offer a high mixing efficiency only in a very limited range of Reynolds numbers (Re). In this work, we developed a 3D fine-threaded lemniscate-shaped micromixer whose maximum numerical and empirical efficiency is around 97% and 93%, respectively, and maintains its high performance (i.e., >90%) over a wide range of 1<Re<1000 which meets the requirements of both the μTAS and microchemical process applications. The 3D micromixer was designed based on two distinct mixing strategies, namely, the inducing of chaotic advection by the presence of Dean flow and diffusive mixing through thread-like grooves around the curved body of the mixers. First, a set of numerical simulations was performed to study the physics of the flow and to determine the essential geometrical parameters of the mixers. Second, a simple and cost-effective method was exploited to fabricate the convoluted structure of the micromixers through the removal of a 3D-printed wax structure from a block of cured polydimethylsiloxane. Finally, the fabricated mixers with different threads were tested using a fluorescent microscope demonstrating a good agreement with the results of the numerical simulation. We envisage that the strategy used in this work would expand the scope of the micromixer technology by broadening the range of efficient working flow rate and providing an easy way to the fabrication of 3D convoluted microstructures
A 3D-printed mini-hydrocyclone for high throughput particle separation: Application to primary harvesting of microalgae
© The Royal Society of Chemistry 2017. The separation of micro-sized particles in a continuous flow is crucial part of many industrial processes, from biopharmaceutical manufacturing to water treatment. Conventional separation techniques such as centrifugation and membrane filtration are largely limited by factors such as clogging, processing time and operation efficiency. Microfluidic based techniques have been gaining great attention in recent years as efficient and powerful approaches for particle-liquid separation. Yet the production of such systems using standard micro-fabrication techniques is proven to be tedious, costly and have cumbersome user interfaces, which all render commercialization difficult. Here, we demonstrate the design, fabrication and evaluation based on CFD simulation as well as experimentation of 3D-printed miniaturized hydrocyclones with smaller cut-size for high-throughput particle/cell sorting. The characteristics of the mini-cyclones were numerically investigated using computational fluid dynamics (CFD) techniques previously revealing that reduction in the size of the cyclone results in smaller cut-size of the particles. To showcase its utility, high-throughput algae harvesting from the medium with low energy input is demonstrated for the marine microalgae Tetraselmis suecica. Final microalgal biomass concentration was increased by 7.13 times in 11 minutes of operation time using our designed hydrocyclone (HC-1). We expect that this elegant approach can surmount the shortcomings of other microfluidic technologies such as clogging, low-throughput, cost and difficulty in operation. By moving away from production of planar microfluidic systems using conventional microfabrication techniques and embracing 3D-printing technology for construction of discrete elements, we envision 3D-printed mini-cyclones can be part of a library of standardized active and passive microfluidic components, suitable for particle-liquid separation
New insights into the physics of inertial microfluidics in curved microchannels. II. Adding an additive rule to understand complex cross-sections.
Curved microchannels allow controllable microparticle focusing, but a full understanding of particle behavior has been limited-even for simple rectangular and trapezoidal shapes. At present, most microfluidic particle separation literature is dedicated to adding "internal" complexity (via sheath flow or obstructions) to relatively simple cross-sectional channel shapes. We propose that, with sufficient understanding of particle behavior, an equally viable pathway for microparticle focusing could utilize complex "external" cross-sectional shapes. By investigating three novel, complex spiral microchannels, we have found that it is possible to passively focus (6, 10, and 13 μm) microparticles in the middle of a convex channel. Also, we found that in concave and jagged channel designs, it is possible to create multiple, tight focusing bands. In addition to these performance benefits, we report an "additive rule" herein, which states that complex channels can be considered as multiple, independent, simple cross-sectional shapes. We show with experimental and numerical analysis that this new additive rule can accurately predict particle behavior in complex cross-sectional shaped channels and that it can help to extract general inertial focusing tendencies for suspended particles in curved channels. Overall, this work provides simple, yet reliable, guidelines for the design of advanced curved microchannel cross sections
Experimental testing of hydrophobic microchannels, with and without nanofluids, for solar PV/T collectors
Solar energy can be converted into useful energy via photovoltaic cells or with a photothermal absorber. While these technologies are well-developed and commercially viable, significant benefits can be realised by pulling these two technologies together in photovoltaic/thermal (PV/T) systems which can provide both heat and electricity from a single collector. Emerging configurations in the PV/T field aim to incorporate micro and/or nanotechnology to boost total solar utilisation even further. One example of this is the nanofluid-based PV/T collector. This type of solar collector utilises nanofluids—suspensions of nanoparticles in traditional heat transfer fluids—as both an optical filter and as a thermal absorber. This concept seeks to harvest the whole solar spectrum at its highest thermodynamic potential through specially engineered nanofluids which transmit the portion of solar spectrum corresponding to the PV response curve while absorbing the rest as heat. Depending on the nanoparticle concentration, employing nanofluids in a flowing system may come with a price—an efficiency penalty in the form of increased pumping power (due to increased viscosity). Similarly, microchannel-based heat exchangers have been shown to increase heat transfer, but they may also pay the price of high pumping power due to additional wall-shear-related pressure drop (i.e., more no-slip boundary area). To develop a novel PV/T configuration which pulls together the advantages of these micro and nanotechnologies with minimal pumping power requirements, the present study experimentally investigated the use of nanofluids in patterned hydrophobic microchannels. It was found that slip with the walls reduced the impact of the increased viscosity of nanofluids by reducing the pressure drop on average 17% relative to a smooth channel. In addition, flowing a selective Ag/SiO2 core–shell nanofluid over a silicon surface (simulating a PV cell underneath the fluid) provided a 20% increase in solar thermal conversion efficiency and ~3% higher stagnation temperature than using pure water. This demonstrates the potential of this proposed system for extracting more useful energy from the same incident flux. Although no electrical energy was extracted from the underlying patterned silicon, this study highlights potential a new development path for micro and nanotechnology to be integrated into next-generation PV/T solar collectors
High-throughput sorting of eggs for synchronization of: C. elegans in a microfluidic spiral chip
© 2018 The Royal Society of Chemistry. In this study, we report the use of a high-throughput microfluidic spiral chip to screen out eggs from a mixed age nematode population, which can subsequently be cultured to a desired developmental stage. For the sorting of a mixture containing three different developmental stages, eggs, L1 and L4, we utilized a microfluidic spiral chip with a trapezoidal channel to obtain a sorting efficiency of above 97% and a sample purity (SP) of above 80% for eggs at different flow rates up to 10 mL min-1. The result demonstrated a cost-effective, simple, and highly efficient method for synchronizing C. elegans at a high throughput (∼4200 organisms per min at 6 mL min-1), while eliminating challenges such as clogging and non-reusability of membrane-based filtration. Due to its simplicity, our method can be easily adopted in the C. elegans research community