19 research outputs found

    Predicting the Route of Delivery in Women with Low-Lying Placenta Using Transvaginal Ultrasonography: Significance of Placental Migration and Marginal Sinus

    Get PDF
    Background/Aims: To examine the significance of placental migration and the presence of a placental marginal sinus to predict the eventual route of delivery in low-lying placenta. Methods: 49 women with a low-lying placenta after 30 weeks' gestation were studied. The distance between the internal os and leading edge of the placenta was measured weekly using transvaginal ultrasonography until 37 weeks' gestation. The relationship between the rate of placental migration, the presence of a placental marginal sinus and the eventual mode of delivery was investigated. Results: Although the cesarean section rate was 56.3% (9/16) in the 'slow' migration (0-2.0 mm/week) group, no patient (0/33) in the 'fast' (>2.0 mm/week) migration group underwent a cesarean section (p<0.01). The cesarean section rate was 71.4% (5/7) in patients with a placental marginal sinus, significantly greater than the rate of 9.5% (4/42) in patients without a marginal sinus (p<0.01). Conclusion:A decreased rate of placental migration until 37 weeks' gestation and the presence of a placental marginal sinus were associated with subsequent cesarean delivery because of antepartum vaginal bleeding. These parameters may be useful for predicting the route of delivery in women with a low-lying placenta.ArticleGYNECOLOGIC AND OBSTETRIC INVESTIGATION. 73(3):217-222 (2012)journal articl

    Analysis of factors influencing the ultrasonic fetal weight estimation

    Get PDF
    Objective: The aim of our study was the evaluation of sonographic fetal weight estimation taking into consideration 9 of the most important factors of influence on the precision of the estimation. Methods: We analyzed 820 singleton pregnancies from 22 to 42 weeks of gestational age. We evaluated 9 different factors that potentially influence the precision of sonographic weight estimation ( time interval between estimation and delivery, experts vs. less experienced investigator, fetal gender, gestational age, fetal weight, maternal BMI, amniotic fluid index, presentation of the fetus, location of the placenta). Finally, we compared the results of the fetal weight estimation of the fetuses with poor scanning conditions to those presenting good scanning conditions. Results: Of the 9 evaluated factors that may influence accuracy of fetal weight estimation, only a short interval between sonographic weight estimation and delivery (0-7 vs. 8-14 days) had a statistically significant impact. Conclusion: Of all known factors of influence, only a time interval of more than 7 days between estimation and delivery had a negative impact on the estimation

    Inter- and intra-observer variability in Sonographic measurements of the cross-sectional diameters and area of the umbilical cord and its vessels during pregnancy

    Get PDF
    Background. The purpose of the study was to evaluate inter- and intra-observer variability in sonographic measurements of the cross-sectional area of the umbilical cord and the diameters of its vessels in low-risk pregnancies of 12 to 40 weeks of gestation. Methods. A prospective cross sectional study was performed in 221 pregnant women at different gestational ages. Measurements were carried out also by a second observer to evaluate inter-observer variability and repeated once again by the first observer to assess intra-observer variability. The linear correlation between the measurements (Spearman's coefficient of correlation) and their reliability through the intraclass correlation coefficient (ICC), the Cronbach's alpha coefficient and the limits of agreement proposed by Bland and Altman were evaluated. Results. The results showed that inter-observer and intra-observer variability did not show any significant difference between examiners. A good linear correlation between the measurements and reliability was obtained, with values of R, ICC and Cronbach's alpha all above the standard limits. Conclusion. It is possible to conclude that inter- and intra-observer variability in the measurements of the umbilical cord and its vessels was small; their reliability and agreement were good. © 2008 Barbieri et al; licensee BioMed Central Ltd
    corecore