377 research outputs found

    Telemonitoring of daily activity and symptom behavior in patients with COPD

    Get PDF
    Objectives. This study investigated the activity behavior of patients with COPD in detail compared to asymptomatic controls, and the relationship between subjective and objective activities (awareness), and readiness to change activity behavior. Methods. Thirty-nine patients with COPD (66.0 years; FEV(1)% predicted: 44.9%) and 21 healthy controls (57.0 years) participated. Objective daily activity was assessed by accelerometry and expressed as amount of activity in counts per minute (cpm). Patients' baseline subjective activity and stage of change were assessed prior to measurements. Results. Mean daily activity in COPD patients was significantly lower compared to the healthy controls (864 ± 277 cpm versus 1162 ± 282 cpm, P < 0.001). COPD patients showed a temporary decrease in objective activities in the early afternoon. Objective and subjective activities were significantly moderately related and most patients (55.3%) were in the maintenance phase of the stages of change. Conclusions. COPD patients show a distinctive activity decrease in the early afternoon. COPD patients are moderately aware of their daily activity but regard themselves as physically active. Therefore, future telemedicine interventions might consider creating awareness of an active lifestyle and provide feedback that aims to increase and balance activity levels

    Mixture randomized item-response modeling:a smoking behavior validation study

    Get PDF
    Misleading response behavior is expected in medical settings where incriminating behavior is negatively related to the recovery from a disease. In the present study, lung patients feel social and professional pressure concerning smoking and experience questions about smoking behavior as sensitive and tend to conceal embarrassing or threatening information. The randomized item-response survey method is expected to improve the accuracy of self-reports as individual item responses are masked and only randomized item responses are observed. We explored the validation of the randomized item-response technique in a unique experimental study. Therefore, we administered a new multi-item measure assessing smoking behavior by using a treatment–control design (randomized response (RR) or direct questioning). After the questionnaire, we administered a breath test by using a carbon monoxide (CO) monitor to determine the smoking status of the patient. We used the response data to measure the individual smoking behavior by using a mixture item-response model. It is shown that the detected smokers scored significantly higher in the RR condition compared with the directly questioned condition. We proposed a Bayesian latent variable framework to evaluate the diagnostic test accuracy of the questionnaire using the randomized-response technique, which is based on the posterior densities of the subject's smoking behavior scores together with the breath test measurements. For different diagnostic test thresholds, we obtained moderate posterior mean estimates of sensitivity and specificity by observing a limited number of discrete randomized item response

    Comparison of a New Multidose Powder Inhaler (Diskus©/Accuhaler©) and the Turbuhaler© Regarding Preference and Ease of Use

    Get PDF
    Many patients with asthma or chronic obstructive pulmonary disease (COPD) use their inhaler ineffectively. Several studies revealed that inhaler-specific design features contributed significantly to the failure rate, which clearly demonstrates the need for developing more “foolproof” inhalers. This study compared ease of use and patient preference of the Diskus®/Accuhaler® (DA) with the Turbuhaler® (TH). Fifty patients with asthma or COPD aged 15 years and older were included in a randomized, crossover comparison of DA with TH regarding patient preference and ease of use. All had to be naïve to DA and TH, but currently had to be using inhaled medication with another device. Inhalation technique was assessed using inhaler-specific checklists and patients had to state a preference for DA or TH regarding various aspects, as well as overall preference. With DA 46 patients (92%) made no errors regarding essential inhalation maneuvers, compared to 37 patients (74%) using TH (p = 0.023) This difference is exclusively caused by not loading the TH properly. When patients were asked which inhaler they would prefer, 17 wanted the DA, 25 the TH, and 8 did not state a preference. The difference was not significant. TH was favored over DA regarding factors related to size and the number of available dosages. The counting mechanism of the DA was preferred over the TH. It seems that patients have a clear, although not statistically significant, preference for TH, but with the DA fewer patients make crucial errors

    Stability in eosinophil categorisation during subsequent severe exacerbations of COPD

    Get PDF
    BACKGROUND: The blood eosinophil count has been shown to be a promising biomarker for establishing personalised treatment strategies to reduce corticosteroid use, either inhaled or systemic, in chronic obstructive pulmonary disease (COPD). Eosinophil levels seem relatively stable over time in stable state, but little is known whether this is also true in subsequent severe acute exacerbations of COPD (AECOPD). AIMS AND OBJECTIVES: To determine the stability in eosinophil categorisation between two subsequent severe AECOPDs employing frequently used cut-off levels. METHODS: During two subsequent severe AECOPDs, blood eosinophil counts were determined at admission to the hospital in 237 patients in the Cohort of Mortality and Inflammation in COPD Study. The following four cut-off levels were analysed: absolute counts of eosinophils ≥0.2×10⁹/L (200 cells/µL) and ≥0.3×10⁹/L (300 cells/µL) and relative eosinophil percentage of ≥2% and ≥3% of total leucocyte count. Categorisations were considered stable if during the second AECOPD their blood eosinophil status led to the same classification: eosinophilic or not. RESULTS: Depending on the used cut-off, the overall stability in eosinophil categorisation varied between 70% and 85% during two subsequent AECOPDs. From patients who were eosinophilic at the first AECOPD, 34%–45% remained eosinophilic at the subsequent AECOPD, while 9%–21% of patients being non-eosinophilic at the first AECOPD became eosinophilic at the subsequent AECOPD. CONCLUSIONS: The eosinophil variability leads to category changes in subsequent AECOPDs, which limits the eosinophil categorisation stability. Therefore, measurement of eosinophils at each new exacerbation seems warranted

    The Effect of Unenhanced MRI on the Surgeons' Decision-Making Process in Females with Suspected Appendicitis

    Get PDF
    This prospective study evaluated the impact of the results of unenhanced magnetic resonance imaging (MRI) on the surgeon's diagnosis of acute appendicitis in potentially fertile females. 112 female patients, aged 12-55, with suspected appendicitis underwent MRI of the abdomen. At three defined intervals; admission and clinical re-evaluation before and after revealing the MRI results, the surgeon recorded the attendance of each patient in operative treatment, observation or discharge. Appendicitis was confirmed or declined by pathology or by telephone follow-up in case of non-intervention. Appendicitis was confirmed in 29 of 112 patients. At admission the surgeon's disposition had a sensitivity of 97 % and specificity of 29 %. After knowing the MRI results, sensitivity was 97 % and specificity 64 %. The sensitivity and specificity of MRI alone were 89 and 100 %, with a negative and positive predictive value of 96 and 100 %, respectively. We believe that MRI should perhaps be standard in all female patients during their reproductive years with suspected appendicitis. It avoids an operation in 32 % of cases and allows earlier planning for patients with an equivocal clinical picture. Trial number: OND1292733 (Narcis.nl)

    The role of cognition in cost-effectiveness analyses of behavioral interventions

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Behavioral interventions typically focus on objective behavioral endpoints like weight loss and smoking cessation. In reality, though, achieving full behavior change is a complex process in which several steps towards success are taken. Any progress in this process may also be considered as a beneficial outcome of the intervention, assuming that this increases the likelihood to achieve successful behavior change eventually. Until recently, there has been little consideration about whether partial behavior change at follow-up should be incorporated in cost-effectiveness analyses (CEAs). The aim of this explorative review is to identify CEAs of behavioral interventions in which cognitive outcome measures of behavior change are analyzed.</p> <p>Methods</p> <p>Data sources were searched for publications before May 2011.</p> <p>Results</p> <p>Twelve studies were found eligible for inclusion. Two different approaches were found: three studies calculated separate incremental cost-effectiveness ratios for cognitive outcome measures, and one study modeled partial behavior change into the final outcome. Both approaches rely on the assumption, be it implicitly or explicitly, that changes in cognitive outcome measures are predictive of future behavior change and may affect CEA outcomes.</p> <p>Conclusion</p> <p>Potential value of cognitive states in CEA, as a way to account for partial behavior change, is to some extent recognized but not (yet) integrated in the field. In conclusion, CEAs should consider, and where appropriate incorporate measures of partial behavior change when reporting effectiveness and hence cost-effectiveness.</p

    Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye

    Get PDF
    AIMS: Cryoballoon pulmonary vein (PV) isolation in patients with atrial fibrillation has proven to be effective in short-term and long-term follow-up. To visualise the PV anatomy, pre-ablation contrast pulmonary venography is commonly performed. Three-dimensional (3D) computed tomography (CT) overlay is a new technique creating a live 3D image of the left atrium by integrating a previously obtained CT scan during fluoroscopy. To evaluate the benefits of 3D CT overlay during cryoballoon ablation, we studied the use of 3D CT overlay versus contrast pulmonary venography in a randomised fashion in patients with paroxysmal atrial fibrillation undergoing cryoballoon PV isolation. METHODS AND RESULTS: Between October 2012 and June 2013, 30 patients accepted for PV isolation were randomised to cryoballoon PV isolation using either 3D CT overlay or contrast pulmonary venography. All patients underwent a pre-procedural cardiac CT for evaluation of the anatomy of the left atrium (LA) and the PVs. In the 3D CT overlay group, a 3D reconstruction of the LA and PVs was made. An overlay of the CT reconstruction was then projected over live fluoroscopy. Patients in the contrast pulmonary venography group received significantly more contrast agent (77.1 ± 21.2 cc vs 40.1 ± 17.6 cc, p < 0.001) and radiation (43.0 ± 21.9 Gy.cm2 vs 28.41 ± 11.7 Gy.cm2, p = 0.04) than subjects in the 3D CT overlay group. There was no difference in total procedure time, fluoroscopy time and the amount of cryoapplications between the two groups. CONCLUSION: The use of 3D CT overlay decreases radiation and contrast dye exposure and can assist in guiding cryoballoon-based PV isolation

    Validation of the oxygen desaturation index in the diagnostic workup of obstructive sleep apnea

    Get PDF
    Introduction: Obstructive sleep apnea (OSA) is common, and diagnosis requires expensive and laborious testing to assess the apnea hypopnea index (AHI). We performed an analysis to explore the relationship between the oxygen desaturation index (ODI) as measured with pulse oximetry and the AHI in our large portable monitoring (PM) database to find an optimal cutoff value for the ODI in order to be able to exclude AHI ≥ 5 on PM. Methods: Three thousand four hundred thirteen PM recordings were randomly divided into a training set (N = 2281) and a test set (N = 1132). The optimal cutoff for the ODI to exclude an AHI ≥ 5 on PM was determined in the training set and subsequently validated in the test set. Results: Area under the curve of the ODI to exclude an AHI ≥ 5 on PM was 0.997 in the training set and 0.996 in the test set. In the training set, the optimal cutoff to predict an AHI < 5 was an ODI < 5. Using this cutoff in the test set provided a sensitivity of 97.7%, a specificity of 97.0%, a positive predictive value of 99.2%, and a negative predictive value of 91.4%. Conclusion: An ODI < 5 predicts an AHI < 5 with high sensitivity and specificity when measured simultaneously using the same oximeter during PM recording
    corecore