486 research outputs found
Pre-cut filter paper for detecting anti-Japanese encephalitis virus IgM from dried cerebrospinal fluid spots
Background The use of filter paper as a simple, inexpensive tool for storage and transportation of blood, 'Dried Blood Spots' or Guthrie cards, for diagnostic assays is well-established. In contrast, there are a paucity of diagnostic evaluations of dried cerebrospinal fluid (CSF) spots. These have potential applications in low-resource settings, such as Laos, where laboratory facilities for central nervous system (CNS) diagnostics are only available in Vientiane. In Laos, a major cause of CNS infection is Japanese encephalitis virus (JEV). We aimed to develop a dried CSF spot protocol and to evaluate its diagnostic performance using the World Health Organisation recommended anti-JEV IgM antibody capture enzyme-linked immunosorbent assay (JEV MAC-ELISA). Methodology and Principal Findings Sample volumes, spotting techniques and filter paper type were evaluated using a CSF-substitute of anti-JEV IgM positive serum diluted in Phosphate Buffer Solution (PBS) to end-limits of detection by JEV MAC-ELISA. A conventional protocol, involving eluting one paper punch in 200 mu l PBS, did not detect the end-dilution, nor did multiple punches utilising diverse spotting techniques. However, pre-cut filter paper enabled saturation with five times the volume of CSF-substitute, sufficiently improving sensitivity to detect the end-dilution. The diagnostic accuracy of this optimised protocol was compared with routine, neat CSF in a pilot, retrospective study of JEV MAC-ELISA on consecutive CSF samples, collected 2009-15, from three Lao hospitals. In comparison to neat CSF, 132 CSF samples stored as dried CSF spots for one month at 25-30 degrees C showed 81.6%(65.7-92.3 95%CI) positive agreement, 96.8% (91.0-99.3 95% CI) negative agreement, with a kappa coefficient of 0.81 (0.70-0.92 95% CI). Conclusions/Significance The novel design of pre-cut filter paper saturated with CSF could provide a useful tool for JEV diagnostics in settings with limited laboratory access. It has the potential to improve national JEV surveillance and inform vaccination policies. The saturation of filter paper has potential use in the wider context of pathogen detection, including dried spots for detecting other analytes in CSF, and other body fluids
On two-dimensional Bessel functions
The general properties of two-dimensional generalized Bessel functions are
discussed. Various asymptotic approximations are derived and applied to analyze
the basic structure of the two-dimensional Bessel functions as well as their
nodal lines.Comment: 25 pages, 17 figure
Development of a short form of Mini-Mental State Examination for the screening of dementia in older adults with a memory complaint: a case control study
<p>Abstract</p> <p>Background</p> <p>Primary care physicians need a brief and accurate screening test of dementia. The objective of this study was to determine whether a short form of Mini-Mental State Examination (SMMSE) was as accurate as the Mini-Mental State Examination (MMSE) in screening dementia.</p> <p>Methods</p> <p>Based on case control design study, SMMSE and MMSE were assessed in 184 community-dwelling older adults (mean age 81.3 ± 6.5 years, 71.7% women) with memory complaint sent by their primary care physician to a memory clinic. Included participants were separated into two groups: cognitively healthy individuals and demented individuals.</p> <p>Results</p> <p>The trade-off between sensitivity and specificity of the SMMSE for clinically diagnosed dementia was 4. Based on the cut-off value †4 for SMMSE and a cut-off value †24 for MMSE, the sensitivity of both tests was similar (89.5% for SMMSE versus 90.0% for MMSE), whereas the specificity, the positive predictive values (PPV) and the negative predictive values (NPV) were higher for SMMSE compared to MMSE (85.4 versus 75.5% for specificity; 95.5% versus 92.8% for PPV; 70.0 versus 68.9 for NPV). The positive and negative Likehood Ratio (LR) of SMMSE were higher than those of MMSE (respectively, 6.1 versus 3.7; 8.1 versus 7.7). In addition, odds ratio (OR) for dementia was higher for the SMMSE compared to the MMSE (OR = 49.8 with 95% confident interval (CI) [18.0; 137.8] versus OR = 28.6 with 95% CI [11.6; 70.3]).</p> <p>Conclusions</p> <p>SMMSE seems to be an efficient short screening test for dementia among community-dwelling older adults with a memory complaint. Further research is needed to confirm its predictive values among unselected primary care older patients.</p
Marine macroalgae as food for earthworms: Growth and selection experiments across ecotypes
Historically, subsistence farmers around the Atlantic coast of NW Europe utilised marine algae as a fertiliser in agroecosystems, a practice that continued in small areas and is now considered to have real potential for re-establishing sustainable food production systems on marginal soils. Earthworms form a significant component of soil fauna and their ecosystem services are well documented. Therefore, palatability of marine organic amendments to faunal detritivores of terrestrial systems is of interest. This work aimed to assess the potential for growth of Aporrectodea caliginosa, Lumbricus rubellus and Aporrectodea longa fed with two common macroalgae (seaweeds), Laminaria digitata and Fucus serratus. In addition, choice chambers were constructed to permit earthworm selection of these macroalgae with more conventional organic materials, horse manure (HM) and birch leaves (BL). Over a period of two months, earthworm species showed significantly greater mass gain with conventional food (p<0.05). Laminaria outperformed Fucus, which in turn was superior to soil alone. Similarly, when given a choice, a significant preference (p<0.001) was shown for the more nitrogen-rich HM and BL over the seaweeds. No removal was recorded for A. caliginosa when offered seaweeds only. By contrast, L. rubellus and A. longa showed significant preferences (p<0.001) for Laminaria over Fucus and fresh material over degraded. These results underline an interest to profit from natural resources (seaweeds) to maintain or improve soil biological quality in marginal coastal areas
Scintillator-based ion beam profiler for diagnosing laser-accelerated ion beams
Next generation intense, short-pulse laser facilities require new high repetition rate diagnostics for the detection of ionizing radiation. We have designed a new scintillator-based ion beam profiler capable of measuring the ion beam transverse profile for a number of discrete energy ranges. The optical response and emission characteristics of four common plastic scintillators has been investigated for a range of proton energies and fluxes. The scintillator light output (for 1 MeV > Ep < 28 MeV) was found to have a non-linear scaling with proton energy but a linear response to incident flux. Initial measurements with a prototype diagnostic have been successful, although further calibration work is required to characterize the total system response and limitations under the high flux, short pulse duration conditions of a typical high intensity laser-plasma interaction
Orientia, rickettsia, and leptospira pathogens as causes of CNS infections in Laos: a prospective study
Background Scrub typhus (caused by Orientia tsutsugamushi), murine typhus (caused by Rickettsia typhi), and
leptospirosis are common causes of febrile illness in Asia; meningitis and meningoencephalitis are severe
complications. However, scarce data exist for the burden of these pathogens in patients with CNS disease in endemic
countries. Laos is representative of vast economically poor rural areas in Asia with little medical information to guide
public health policy. We assessed whether these pathogens are important causes of CNS infections in Laos.
Methods Between Jan 10, 2003, and Nov 25, 2011, we enrolled 1112 consecutive patients of all ages admitted with CNS
symptoms or signs requiring a lumbar puncture at Mahosot Hospital, Vientiane, Laos. Microbiological examinations
(culture, PCR, and serology) targeted so-called conventional bacterial infections (Streptococcus pneumoniae, Neisseria
meningitidis, Haemophilus infl uenzae, S suis) and O tsutsugamushi, Rickettsia typhi/Rickettsia spp, and Leptospira spp
infections in blood or cerebrospinal fl uid (CSF). We analysed and compared causes and clinical and CSF characteristics
between patient groups.
Findings 1051 (95%) of 1112 patients who presented had CSF available for analysis, of whom 254 (24%) had a CNS
infection attributable to a bacterial or fungal pathogen. 90 (35%) of these 254 infections were caused by O tsutsugamushi,
R typhi/Rickettsia spp, or Leptospira spp. These pathogens were signifi cantly more frequent than conventional bacterial
infections (90/1051 [9%] vs 42/1051 [4%]; p<0·0001) by use of conservative diagnostic defi nitions. CNS infections had
a high mortality (236/876 [27%]), with 18% (13/71) for R typhi/Rickettsia spp, O tsutsugamushi, and Leptospira spp
combined, and 33% (13/39) for conventional bacterial infections (p=0·076).
Interpretation Our data suggest that R typhi/Rickettsia spp, O tsutsugamushi, and Leptospira spp infections are
important causes of CNS infections in Laos. Antibiotics, such as tetracyclines, needed for the treatment of murine
typhus and scrub typhus, are not routinely advised for empirical treatment of CNS infections. These severely neglected infections represent a potentially large proportion of treatable CNS disease burden across vast endemic areas and need more attention
The effectiveness of the 13-valent pneumococcal conjugate vaccine against hypoxic pneumonia in children in Lao People's Democratic Republic: An observational hospital-based test-negative study
Background: Pneumococcal pneumonia is a leading cause of childhood mortality. Pneumococcal conjugate vaccines (PCVs) have been shown to reduce hypoxic pneumonia in children. However, there are no studies from Asia examining the effectiveness of PCVs on hypoxic pneumonia. We describe a novel approach to determine the effectiveness of the 13-valent PCV (PCV13) against hypoxia in children admitted with pneumonia in the Lao People's Democratic Republic. Methods: A prospective hospital-based, test-negative observational study of children aged up to 59 months admitted with pneumonia to a single tertiary hospital in Vientiane was undertaken over 54 months. Pneumonia was defined using the 2013 WHO definition. Hypoxia was defined as oxygen saturation <90% in room air or requiring oxygen supplementation during hospitalisation. Test-negative cases and controls were children with hypoxic and non-hypoxic pneumonia, respectively. PCV13 status was determined by written record. Vaccine effectiveness was calculated using logistic regression. Propensity score and multiple imputation analyses were used to handle confounding and missing data. Findings: There were 826 children admitted with pneumonia, 285 had hypoxic pneumonia and 377 were PCV13-vaccinated. The unadjusted, propensity-score adjusted and multiple-imputation adjusted estimates of vaccine effectiveness against hypoxic pneumonia were 23% (95% confidence interval: -9, 46%; p=0âą14); 37% (6, 57%; p=0âą02) and 35% (7, 55%; p=0âą02) respectively. Interpretation: PCV13 is effective against hypoxic pneumonia in Asia, and should be prioritised for inclusion in national immunisation programs. This single hospital-based, test-negative approach can be used to assess vaccine effectiveness in other similar settings. Funding: Funded by the Bill & Melinda Gates Foundation
Repurposing rapid diagnostic tests to detect falsified vaccines in supply chains
Substandard (including degraded) and falsified (SF) vaccines are a relatively neglected issue with serious global implications for public health. This has been highlighted during the rapid and widespread rollout of COVID-19 vaccines. There has been increasing interest in devices to screen for SF non-vaccine medicines including tablets and capsules to empower inspectors and standardise surveillance. However, there has been very limited published research focussed on repurposing or developing new devices for screening for SF vaccines. To our knowledge, rapid diagnostic tests (RDTs) have not been used for this purpose but have important potential for detecting falsified vaccines. We performed a proof-in-principle study to investigate their diagnostic accuracy using a diverse range of RDT-vaccine/falsified vaccine surrogate pairs. In an initial assessment, we demonstrated the utility of four RDTs in detecting seven vaccines. Subsequently, the four RDTs were evaluated by three blinded assessors with seven vaccines and four falsified vaccines surrogates. The results provide preliminary data that RDTs could be used by multiple international organisations, national medicines regulators and vaccine manufacturers/distributors to screen for falsified vaccines in supply chains, aligned with the WHO global âPrevent, Detect and Respondâ strategy
- âŠ