284 research outputs found

    Measurement of the drift field in the ARGONTUBE LAr TPC with 266~nm pulsed laser beams

    Get PDF
    ARGONTUBE is a liquid argon time projection chamber (LAr TPC) with a drift field generated in-situ by a Greinacher voltage multiplier circuit. We present results on the measurement of the drift-field distribution inside ARGONTUBE using straight ionization tracks generated by an intense UV laser beam. Our analysis is based on a simplified model of the charging of a multi-stage Greinacher circuit to describe the voltages on the field cage rings

    A method to suppress dielectric breakdowns in liquid argon ionization detectors for cathode to ground distances of several millimeters

    Get PDF
    We present a method to reach electric field intensity as high as 400 kV/cm in liquid argon for cathode-ground distances of several millimeters. This can be achieved by suppressing field emission from the cathode, overcoming limitations that we reported earlier

    On the Electric Breakdown in Liquid Argon at Centimeter Scale

    Get PDF
    We present a study on the dependence of electric breakdown discharge properties on electrode geometry and the breakdown field in liquid argon near its boiling point. The measurements were performed with a spherical cathode and a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of the time evolution of the breakdown volt-ampere characteristics was performed for the first time. It revealed a slow streamer development phase in the discharge. The results of a spectroscopic study of the visible light emission of the breakdowns complement the measurements. The light emission from the initial phase of the discharge is attributed to electro-luminescence of liquid argon following a current of drifting electrons. These results contribute to set benchmarks for breakdown-safe design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).Comment: Minor revision according to editor report. 17 pages, 15 figures, 2 tables. Turboencabulato

    ArCLight - a Compact Dielectric Large-Area Photon Detector

    Get PDF
    ArCLight is a novel device for detecting scintillation light over large areas with Photon Detection Efficiency (PDE) of the order of a few percent. Its robust technological design allows for efficient use in large-volume particle detectors, such as Liquid Argon Time Projection Chambers (LArTPCs) or liquid scintillator detectors. Due to its dielectric structure it can be placed inside volumes with high electric field. It could potentially replace vacuum PhotoMultiplier Tubes (PMTs) in applications where high PDE is not required. The photon detection efficiency for a 10x10cm2 detector prototype was measured to be in the range of 0.8% to 2.2% across the active area

    Experimental study of electric breakdowns in liquid argon at centimeter scale

    Full text link
    In this paper we present results on measurements of the dielectric strength of liquid argon near its boiling point and cathode-anode distances in the range of 0.1 mm to 40 mm with spherical cathode and plane anode. We show that at such distances the applied electric field at which breakdowns occur is as low as 40 kV/cm. Flash-overs across the ribbed dielectric of the high voltage feed-through are observed for a length of 300 mm starting from a voltage of 55 kV. These results contribute to set reference for the breakdown-free design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC)

    First Demonstration of a Pixelated Charge Readout for Single-Phase Liquid Argon Time Projection Chambers

    Full text link
    Liquid Argon Time Projection Chambers (LArTPCs) have been selected for the future long-baseline Deep Underground Neutrino Experiment (DUNE). To allow LArTPCs to operate in the high-multiplicity near detector environment of DUNE, a new charge readout technology is required. Traditional charge readout technologies introduce intrinsic ambiguities, combined with a slow detector response, these ambiguities have limited the performance of LArTPCs, until now. Here, we present a novel pixelated charge readout that enables the full 3D tracking capabilities of LArTPCs. We characterise the signal to noise ratio of charge readout chain, to be about 14, and demonstrate track reconstruction on 3D space points produced by the pixel readout. This pixelated charge readout makes LArTPCs a viable option for the DUNE near detector complex.Comment: 13 pages, 9 figure

    The value of Statistical Shape Models to Spine Surgery

    Get PDF
    The increased use of 3D models of organs or bones by the surgeon has lead to rapid development of new methods to automaKze model generaKon

    Outcomes of care during the last month of life: a systematic review to inform the development of a core outcome set.

    Get PDF
    BACKGROUND To date, there is a lack of standardization and consensus on which outcomes are central to assess the care provided to patients in the last month of life. Therefore, we aimed to conduct a systematic review to identify relevant outcomes to inform the development of a core outcome set for the best care for the dying person. METHODS We conducted a systematic review of outcomes reported in the scientific literature about the care for the dying person in the last month of life. We searched for peer-reviewed studies published before February 2022 in four electronic databases. To categorise the outcomes, we employed the taxonomy developed by the "Core Outcome Measures in Effectiveness Trials" collaboration. RESULTS Out of the 2,933 articles retrieved, 619 were included for analyses. The majority of studies (71%) were retrospective and with data extracted from chart reviews (71%) . We extracted 1,951 outcomes in total, from which, after deletion of repeated outcomes, we identified 256 unique ones. The most frequently assessed outcomes were those related to medication or therapeutic interventions and those to hospital/ healthcare use. Outcomes related to psychosocial wellbeing were rarely assessed. The closer to death, the less frequently the outcomes were studied. CONCLUSIONS Most outcomes were related to medical interventions or to hospital use. Only a few studies focused on other components of integrated care such as psychosocial aspects. It remains to be defined which of these outcomes are fundamental to achieve the best care for the dying
    corecore