67 research outputs found

    Norplant in Zimbabwe: preliminary report

    Get PDF
    A research study on the introduction and effective use of Norplant as a family planning and birth control method used by women of child-bearing age, in Zimbabwe.During an ongoing study of a pre-introduction trial of Norplant in Zimbabwe, 197 women had the subdermal implant of six capsules containing levonorgestrel inserted between June and December 1991, atParirenyatwa, Harare Hospital and Spilhaus. Acceptability and efficacy were high and no significant side effects had been observed. Three implants were removed due to local infection, Our initial experience indicates that the Norplant continuation rate is much higher than for any other reversible method of contraception and it is highly acceptable as a long term contraceptive

    Developing Innovation Competence Profile For Teaching Staff In Higher Education In Uganda

    Get PDF
    Higher education across the globe is under increasing pressure to prepare students with innovation capacities to address challenges facing humanity in the 21st century and beyond. A call for innovative graduates without first understanding the factors that impede higher education institutions from acting as catalysts of innovation is not judicious. One of the notable factors that has been advanced is the lack of adequate competent teachers to let students develop innovation skills. This paper explores competence domains with their underlying competencies teaching staff require to act competently in the innovation field as well as being able to prepare students with the capability to foster innovation at the place of work. The study employed a mixed research design involving systematic literature search, exploratory survey, and three focus group discussions. The study was conducted in four stages. After stage one, four teacher innovation competence domains and 17 underlying competencies were identified. After the consultation questionnaire and focus group discussions, one competence domain was added to the profile and two competencies considered irrelevant were omitted. The study presents five innovation competence domains (teaching staff as: an innovator, knowledge society developer, networker and collaborator, higher education designer and developer, and entrepreneur) and15 underlying competencies

    Condensed-Phase Photochemistry in the Absence of Radiation Chemistry

    Get PDF
    We report post-irradiation photochemistry studies of condensed ammonia using photons of energies below condensed ammonia’s ionization threshold of ~ 9 eV. Hydrazine (N2H4), diazene (also known as diimide and diimine) (N2H2), triazane (N3H5), and one or more isomers of N3H3 are detected as photochemistry products during temperature-programmed desorption. Product yields increase monotonically with (1) photon fluence and (2) film thickness. In the studies reported herein, the energies of photons responsible for product formation are constrained to less than 7.4 eV. Previous post-irradiation photochemistry studies of condensed ammonia employed photons sufficiently energetic to ionize condensed ammonia and initiate radiation chemistry. Such studies typically involve ion-molecule reactions and electron-induced reactions in addition to photochemistry. Although photochemistry is cited as a dominant mechanism for the synthesis of prebiotic molecules in interstellar ices, to the best of our knowledge, ours is one of the first astrochemically-relevant studies that has found unambiguous evidence for condensed-phase chemical synthesis induced by photons in the absence of ionization

    Acute childhood diarrhoea in northern Ghana: epidemiological, clinical and microbiological characteristics

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Acute diarrhoea is a major cause of childhood morbidity and mortality in sub-Saharan Africa. Its microbiological causes and clinico-epidemiological aspects were examined during the dry season 2005/6 in Tamale, urban northern Ghana.</p> <p>Methods</p> <p>Stool specimens of 243 children with acute diarrhoea and of 124 control children were collected. Patients were clinically examined, and malaria and anaemia were assessed. Rota-, astro-, noro- and adenoviruses were identified by (RT-) PCR assays. Intestinal parasites were diagnosed by microscopy, stool antigen assays and PCR, and bacteria by culturing methods.</p> <p>Results</p> <p>Watery stools, fever, weakness, and sunken eyes were the most common symptoms in patients (mean age, 10 months). Malaria occurred in 15% and anaemia in 91%; underweight (22%) and wasting (19%) were frequent. Intestinal micro-organisms were isolated from 77% of patients and 53% of controls (<it>P </it>< 0.0001). The most common pathogens in patients were rotavirus (55%), adenovirus (28%) and norovirus (10%); intestinal parasites (5%) and bacteria (5%) were rare. Rotavirus was the only pathogen found significantly more frequently in patients than in controls (odds ratio 7.7; 95%CI, 4.2–14.2), and was associated with young age, fever and watery stools. Patients without an identified cause of diarrhoea more frequently had symptomatic malaria (25%) than those with diagnosed intestinal pathogens (12%, <it>P </it>= 0.02).</p> <p>Conclusion</p> <p>Rotavirus-infection is the predominant cause of acute childhood diarrhoea in urban northern Ghana. The abundance of putative enteropathogens among controls may indicate prolonged excretion or limited pathogenicity. In this population with a high burden of diarrhoeal and other diseases, sanitation, health education, and rotavirus-vaccination can be expected to have substantial impact on childhood morbidity.</p

    A 3-year multicentre randomized controlled trial of etonogestrel- and levonorgestrel-releasing contraceptive implants, with non-randomized matched copper-intrauterine device controls

    Get PDF
    STUDY QUESTION Is there any difference in the clinical performance of the 3-year one-rod etonogestrel (ENG)- and the 5-year two-rod levonorgestrel (LNG)-releasing contraceptive implants during 3 years of insertion, and between implant and intrauterine device (IUD) contraception, in particular complaints possibly related to hormonal contraceptives? SUMMARY ANSWER The cumulative contraceptive effectiveness after 3 years and method continuation through 2.5 years were not significantly different between ENG and LNG implants, but both outcomes were significantly worse in the non-randomized age-matched group of IUD users than in the combined implant group. WHAT IS KNOWN ALREADY ENG- and LNG-releasing implants are safe and highly efficacious contraceptives with pregnancy rates reported to be 0.0-0.5 per 100 women-years (W-Y). No head-to-head comparative study of the two implants has been undertaken, and little information is available on comparisons of complaints of side effects of implant and copper IUD users. STUDY DESIGN, SIZE, DURATION This was an open parallel group RCT with 1:1 allocation ratio of the ENG and the LNG implants with non-randomized control group of women choosing TCu380A IUD to address lack of reliable data on common side effects typically attributed to the use of progestogen-only contraceptives. After device(s) placement, follow-ups were at 2 weeks, 3 and 6 months, and semi-annually thereafter for 3 years or until pregnancy, removal or expulsion of the implant/IUD occurred. PARTICIPANTS, SETTING, METHODS The study took place in family planning clinics in Brazil, Chile, Dominican Republic, Hungary, Thailand, Turkey and Zimbabwe. Women seeking long-term contraception were enlisted after an eligibility check and informed consent, and 2982 women were enrolled: 1003, 1005 and 974 in the ENG-implant, LNG-implant and IUD groups, respectively; 995, 997 and 971, respectively, were included in the per protocol analysis reported here. MAIN RESULTS AND THE ROLE OF CHANCE ENG and LNG implants each had the same 3-year cumulative pregnancy rate of 0.4 per 100 W-Y [95% confidence interval (CI) 0.1-1.4]. A weight of ≥70 kg at admission was unrelated to pregnancy. Method continuation rates for ENG and LNG implants at 2.5 years were 69.8 (95% CI 66.8-72.6) and 71.8 per 100 W-Y (68.8-74.5), and at 3 years 12.1 (95% CI 5.2-22.0) and 52.0 per 100 W-Y (95% CI 41.8-61.2), respectively. Bleeding disturbances, the most frequent reason for method discontinuation, were significantly more common in the ENG group [16.7 (95% CI 14.4-19.3)] than in the LNG group [12.5 (95% CI 10.5-14.9)] (P 0.019). The 3-year cumulative loss to follow-up was lower in the ENG- than in the LNG-implant group, 8.1 (95% CI 6.4-10.2) and 14.4 per 100 W-Y (95% CI 12.1-17.1), respectively. The median duration of implant removal was 50 s shorter among women with ENG than among women with LNG implant (P < 0.0001). In the observational comparison between IUD and implant users, the 3-year relative risk for pregnancy in IUD group compared with the combined implant group was 5.7 per 100 W-Y (95% CI 4.4-7.3) (P = 0.0003). The 3-year expulsion rate of the IUD was 17.8 per 100 W-Y (95% CI 14.5-21.9), while the discontinuation rate for bleeding disturbances was 8.5 (95% CI 6.7-10.9). Frequency of complaints of headache and dizziness was not significantly different between implant and IUD users (P = 0.16 and 0.77, respectively), acne and bleeding irregularities were more frequent among implant users (P < 0.0001), while heavy bleeding and lower abdominal pain occurred more often among IUD than implant users (P < 0.0001). LIMITATIONS, REASONS FOR CAUTION Few women were ≤19 years old or nulligravida, the proportion of implant users ≥70 kg was <20% and <8% were obese. WIDER IMPLICATIONS OF THE FINDINGS Findings of the study can inform policy makers and clinicians about choice of implant, but also about TCu380A IUD in relation to implants. STUDY FUNDING/COMPETING INTEREST(S) UNDP/UNFPA/WHO/UNICEF/World Bank Special Programme of Research, Development and Research Training in Human Reproduction (HRP), Department of Reproductive Health and Research (RHR), World Health Organization (WHO). This report contains the views of an international expert group and does not necessarily represent the decisions or the stated policy of the WHO. TRIAL REGISTRATION ISRCTN33378571 registered on 22 March 2004. The first participant was enrolled on 12 May 200

    Uganda's experience in Ebola virus disease outbreak preparedness, 2018-2019.

    Get PDF
    BACKGROUND: Since the declaration of the 10th Ebola Virus Disease (EVD) outbreak in DRC on 1st Aug 2018, several neighboring countries have been developing and implementing preparedness efforts to prevent EVD cross-border transmission to enable timely detection, investigation, and response in the event of a confirmed EVD outbreak in the country. We describe Uganda's experience in EVD preparedness. RESULTS: On 4 August 2018, the Uganda Ministry of Health (MoH) activated the Public Health Emergency Operations Centre (PHEOC) and the National Task Force (NTF) for public health emergencies to plan, guide, and coordinate EVD preparedness in the country. The NTF selected an Incident Management Team (IMT), constituting a National Rapid Response Team (NRRT) that supported activation of the District Task Forces (DTFs) and District Rapid Response Teams (DRRTs) that jointly assessed levels of preparedness in 30 designated high-risk districts representing category 1 (20 districts) and category 2 (10 districts). The MoH, with technical guidance from the World Health Organisation (WHO), led EVD preparedness activities and worked together with other ministries and partner organisations to enhance community-based surveillance systems, develop and disseminate risk communication messages, engage communities, reinforce EVD screening and infection prevention measures at Points of Entry (PoEs) and in high-risk health facilities, construct and equip EVD isolation and treatment units, and establish coordination and procurement mechanisms. CONCLUSION: As of 31 May 2019, there was no confirmed case of EVD as Uganda has continued to make significant and verifiable progress in EVD preparedness. There is a need to sustain these efforts, not only in EVD preparedness but also across the entire spectrum of a multi-hazard framework. These efforts strengthen country capacity and compel the country to avail resources for preparedness and management of incidents at the source while effectively cutting costs of using a "fire-fighting" approach during public health emergencies

    The impact of tubal ectopic pregnancy in Papua New Guinea - a retrospective case review

    Get PDF
    BACKGROUND: Ectopic pregnancy (EP) is an important cause of morbidity and mortality amongst women of reproductive age. Tubal EP is well described in industrialised countries, but less is known about its impact in low-resource countries, in particular in the South Pacific Region. METHODS: We undertook a retrospective review of women with tubal EP treated at a provincial referral hospital in coastal Papua New Guinea over a period of 56 months. Demographic and clinical variables were obtained from patients’ medical records and analysed. The institutional rate of tubal EP was calculated, and diagnosis and management reviewed. Potential risk factors for tubal EP were identified, and delays contributing to increased morbidity described. RESULTS: A total of 73 women had tubal EP. The institutional rate of tubal EP over the study period was 6.3 per 1,000 deliveries. There were no maternal deaths due to EP. The mean age of women was 31.5+/−5.7 years, 85% were parous, 67% were rural dwellers and 62% had a history of sub-fertility. The most commonly used diagnostic aid was culdocentesis. One third of women had clinical evidence of shock on arrival. All women with tubal EP were managed by open salpingectomy. Tubal rupture was confirmed for 48% of patients and was more common amongst rural dwellers. Forty-three percent of women had macroscopic evidence of pelvic infection. Two-thirds of patients received blood transfusions, and post-operative recovery lasted six days on average. Late presentation, lack of clinical suspicion, and delays with receiving appropriate treatments were observed. CONCLUSIONS: Tubal EP is a common gynaecological emergency in a referral hospital in coastal PNG, and causes significant morbidity, in particular amongst women residing in rural areas. Sexually transmitted infections are likely to represent the most important risk factor for tubal EP in PNG. Interventions to reduce the morbidity due to tubal EP include the prevention, detection and treatment of sexually transmitted infections, identification and reduction of barriers to prompt presentation, increasing health workers’ awareness of ectopic pregnancy, providing pregnancy test kits to rural health centres, and strengthening hospital blood transfusion services, including facilities for autotransfusion

    The 2021 WHO catalogue of Mycobacterium tuberculosis complex mutations associated with drug resistance: a genotypic analysis.

    Get PDF
    Background: Molecular diagnostics are considered the most promising route to achievement of rapid, universal drug susceptibility testing for Mycobacterium tuberculosis complex (MTBC). We aimed to generate a WHO-endorsed catalogue of mutations to serve as a global standard for interpreting molecular information for drug resistance prediction. Methods: In this systematic analysis, we used a candidate gene approach to identify mutations associated with resistance or consistent with susceptibility for 13 WHO-endorsed antituberculosis drugs. We collected existing worldwide MTBC whole-genome sequencing data and phenotypic data from academic groups and consortia, reference laboratories, public health organisations, and published literature. We categorised phenotypes as follows: methods and critical concentrations currently endorsed by WHO (category 1); critical concentrations previously endorsed by WHO for those methods (category 2); methods or critical concentrations not currently endorsed by WHO (category 3). For each mutation, we used a contingency table of binary phenotypes and presence or absence of the mutation to compute positive predictive value, and we used Fisher's exact tests to generate odds ratios and Benjamini-Hochberg corrected p values. Mutations were graded as associated with resistance if present in at least five isolates, if the odds ratio was more than 1 with a statistically significant corrected p value, and if the lower bound of the 95% CI on the positive predictive value for phenotypic resistance was greater than 25%. A series of expert rules were applied for final confidence grading of each mutation. Findings: We analysed 41 137 MTBC isolates with phenotypic and whole-genome sequencing data from 45 countries. 38 215 MTBC isolates passed quality control steps and were included in the final analysis. 15 667 associations were computed for 13 211 unique mutations linked to one or more drugs. 1149 (7·3%) of 15 667 mutations were classified as associated with phenotypic resistance and 107 (0·7%) were deemed consistent with susceptibility. For rifampicin, isoniazid, ethambutol, fluoroquinolones, and streptomycin, the mutations' pooled sensitivity was more than 80%. Specificity was over 95% for all drugs except ethionamide (91·4%), moxifloxacin (91·6%) and ethambutol (93·3%). Only two resistance mutations were identified for bedaquiline, delamanid, clofazimine, and linezolid as prevalence of phenotypic resistance was low for these drugs. Interpretation: We present the first WHO-endorsed catalogue of molecular targets for MTBC drug susceptibility testing, which is intended to provide a global standard for resistance interpretation. The existence of this catalogue should encourage the implementation of molecular diagnostics by national tuberculosis programmes. Funding: Unitaid, Wellcome Trust, UK Medical Research Council, and Bill and Melinda Gates Foundation

    Abortion: attitudes and perceptions of health professionals in Zimbabwe

    No full text
    No Abstract. Central African Journal of Medicine Vol. 45 (9) 1999: pp. 239-24
    • …
    corecore