49 research outputs found
TESTING OF THE DUAL ROTARY FILTER SYSTEM
The Savannah River National Laboratory (SRNL) installed and tested two hydraulically connected SpinTek rotary microfilter (RMF) units to determine the behavior of a multiple filter system. Both units were successfully controlled by a control scheme written in DELTA-V architecture by Savannah River Remediation (SRR) Process Control Engineering personnel. The control system was tuned to provide satisfactory response to changing conditions during the operation of the multi-filter system. Stability was maintained through the startup and shutdown of one of the filter units while the second was still in operation. The installation configuration originally proposed by the Small Colum Ion Exchange (SCIX) project of independent filter and motor mountings may be susceptible to vibration. Significant stiffening of the filter and motor mounts was required to minimize the vibration. Alignment of the motor to the filter was a challenge in this test configuration. The deployment configuration must be easy to manipulate and allow for fine adjustment. An analysis of the vibration signature of the test system identified critical speeds. Whether it corresponds to the resonance frequency of a rotor radial vibration mode that was excited by rotor unbalance is uncertain based upon the measurements. A relative motion series should be completed on the filter with the final shaft configuration to determine if the resonances exist in the final filter design. The instrumentation selected for deployment, including the concentrate discharge control valve and flow meters, performed well. Automation of the valve control integrated well with the control scheme and when used in concert with the other control variables, allowed automated control of the dual RMF system. The one area of concern with the instrumentation was the condition resulting when the filtrate flow meter operated with less than three gpm. This low flow was at the lower range of performance for the flow meter. This should not be an issue in deployment where the desired flow rate will be within the normal operating range of the meter. Testing demonstrated that the use of a flexible line for the filtrate discharge is highly desired at the outlet of the rotary union to transition to the system piping. Isolating the vibration from the rotary union will significantly improve the lifetime of the seals. Methods to monitor and isolate individual filters should be considered during deployment. The ability to diagnose issues and isolate individual filters would allow isolation prior to failure. Thus, filters may be cleaned or repaired instead of requiring complete replacement if the condition were to continue unnoticed. Isolating the filtrate line of each filter during startup will minimize the premature buildup of solids on the filter disks. Several tests have shown that the method of filter startup can improve performance lifetime of the filters. The installation must factor in an air inlet for the draining of a filter that does not involve a reverse flow through the filter disks. The reverse flow may cause deformation of the disks or may damage other components of the filters themselves
Recommended from our members
TESTING OF THE DUAL ROTARY FILTER SYSTEM
The Savannah River National Laboratory (SRNL) installed and tested two hydraulically connected SpinTek rotary microfilter (RMF) units to determine the behavior of a multiple filter system. Both units were successfully controlled by a control scheme written in DELTA-V architecture by Savannah River Remediation (SRR) Process Control Engineering personnel. The control system was tuned to provide satisfactory response to changing conditions during the operation of the multi-filter system. Stability was maintained through the startup and shutdown of one of the filter units while the second was still in operation. The installation configuration originally proposed by the Small Colum Ion Exchange (SCIX) project of independent filter and motor mountings may be susceptible to vibration. Significant stiffening of the filter and motor mounts was required to minimize the vibration. Alignment of the motor to the filter was a challenge in this test configuration. The deployment configuration must be easy to manipulate and allow for fine adjustment. An analysis of the vibration signature of the test system identified critical speeds. Whether it corresponds to the resonance frequency of a rotor radial vibration mode that was excited by rotor unbalance is uncertain based upon the measurements. A relative motion series should be completed on the filter with the final shaft configuration to determine if the resonances exist in the final filter design. The instrumentation selected for deployment, including the concentrate discharge control valve and flow meters, performed well. Automation of the valve control integrated well with the control scheme and when used in concert with the other control variables, allowed automated control of the dual RMF system. The one area of concern with the instrumentation was the condition resulting when the filtrate flow meter operated with less than three gpm. This low flow was at the lower range of performance for the flow meter. This should not be an issue in deployment where the desired flow rate will be within the normal operating range of the meter. Testing demonstrated that the use of a flexible line for the filtrate discharge is highly desired at the outlet of the rotary union to transition to the system piping. Isolating the vibration from the rotary union will significantly improve the lifetime of the seals. Methods to monitor and isolate individual filters should be considered during deployment. The ability to diagnose issues and isolate individual filters would allow isolation prior to failure. Thus, filters may be cleaned or repaired instead of requiring complete replacement if the condition were to continue unnoticed. Isolating the filtrate line of each filter during startup will minimize the premature buildup of solids on the filter disks. Several tests have shown that the method of filter startup can improve performance lifetime of the filters. The installation must factor in an air inlet for the draining of a filter that does not involve a reverse flow through the filter disks. The reverse flow may cause deformation of the disks or may damage other components of the filters themselves
Recommended from our members
TESTING OF THE SECOND GENERATION SPINTEK ROTARY FILTER -11357
The SpinTek rotary microfilter has been developed under the Department of Energy (DOE) Office of Environmental Management (EM) for the purpose of deployment in radioactive service in the DOE complex. The unit that was fabricated and tested is the second generation of the filter that incorporates recommended improvements from previous testing. The completion of this test satisfied a key milestone for the EM technology development program and technology readiness for deployment by Savannah River Remediation in the Small Column Ion Exchange and Sludge Washing processes at the Savannah River Site (SRS). The Savannah River National Laboratory (SRNL) contracted SpinTek Filtration to fabricate a full scale 25 disk rotary filter and perform a 1000 hour endurance test with a simulated SRS sludge. Over 1500 hours of operation have been completed with the filter. SpinTek Filtration fabricated a prototypic 25 disk rotary filter including updates to manufacturing tolerances, an updated design to the rotary joint, improved cooling to the bottom journal, decreases in disk and filter shaft hydraulic resistances. The filter disks were fabricated with 0.5 {micro} pore size, sintered-metal filter media manufactured by Pall Corporation (M050). After fabrication was complete, the filter passed acceptance tests demonstrating rejection of solids and clean water flux with a 50% improvement over the previous filters. Once the acceptance test was complete, a 1000 hour endurance test was initiated simulating a sludge washing process. The test used a simulated SRS Sludge Batch 6 recipe. The insoluble solids started at 5 wt% and were raised to 10 and 15 wt% insoluble solids to simulate the concentration of a large volume tank. The filter system was automated and set up for 24 hour unattended operation. To facilitate this, process control logic was written to operate the filter. During the development it was demonstrated that the method of starting and stopping the filter can affect the build up of filter cake on the disks and therefore the performance of the filter. The filter performed well with the simulant. Very little drop in production was noticed between the 5 and 10 wt% insoluble solids feed. Increasing to 15 wt% had a more pronounced impact due to the rheology of the feed. Acid cleaning was used to clean the filter disks in-situ and restore filtration rate to almost 90% of the initial clean disk rate. Eighty liters of 0.2 M nitric acid in conjunction with water rinses were used to clean the filter in less than 2 hours. Filter testing was completed after 1000 hours of operation were performed on the final filter assembly configuration. The total run time for the testing was over 1500 hours. At the end of the test, the sludge washing was performed successfully from approximately 5.6 M to less than 1 M sodium
Recommended from our members
Spherical Resorcinol-Formaldehyde Resin for the Removal of Cesium from Hanford Tank Waste
Recommended from our members
Entrainment of Solvent in Aqueous Stream from CINC V-5 Contactor
Personnel completed a rapid study of organic entrainment during operation of a CINC V-5 contactor under prototypical conditions covering the range of expected MCU operation. The study only considered the entrainment of organic into the strip acid effluent destined for the Defense Waste Processing Facility. Based on this work, the following observations are noted: (1) Concentrations of total organic from the contactor discharge, based upon modifier measurements, in the acid typically averaged 330 ppm{sub m}, for a range to 190-610 ppm{sub m}. (2) Entrained droplet sizes remained below 18 microns for samples collected at the decanter outlet and below 11 microns for samples taken from the contactor discharge. (3) Scouting tests showed that a vendor coalescer material promotes coalescence of smaller size droplets from the decanter effluent. (4) Personnel observed a previously unreported organic impurity in the solvent used for this study. Additional efforts are needed to ascertain the source of the impurity and its implication on the overall process. (5) Process throughputs and planned operating conditions result in very stable hydraulics, suggesting that the MCU stripping stages will have spare operating capacity. (6) The V-5 contactors show operated with relatively cool surfaces under the planned operating conditions. (7) If operating conditions result in an imbalance of the relative mixing and separation conditions within the contactor, a very stable emulsion may result. In this instance, the emulsion remained stable for weeks. The imbalance in this study resulted from use of improperly sized weir plates. (8) Personnel demonstrated an effective means of recovering emulsified solvent following a non-optimal equipment configuration. The protocols developed may offer benefit for MCU and SWPF operations. (9) This study developed and demonstrated the effectiveness of several analytical methods for support of the Caustic-Side Solvent Extraction process including infrared spectroscopy and droplet size measurement by a MicroTrac{trademark} S3000. Interfacial tension measurements also showed sensitivity to purity of the solvent suggesting that this technique may prove valuable for future process diagnostics. The study highlighted limitations of the current gas chromatography configuration for determination of modifier content of samples. Additional development of analytical methods for determining composition--and particularly modifier content--of organic and mixed aqueous-organic samples is warranted. Infrared spectroscopy shows particular promise. Additional full-scale studies are warranted to investigate the entrainment of organic in the aqueous effluent from the extraction operation. Since waste composition may differ appreciably for the process, this stream may exhibit much wider variance in hydraulic behavior, organic entrainment, and may pose a greater risk for poor hydraulics. Conducting contactor studies at SRNL allowed numerous personnel to view operations and facilitated the training of staff members. Members of the Design Authority, Engineering, and Training groups benefited from tours. Consideration should be given to procuring and installing a full-scale contactor at SRNL for future support and for assistance during commissioning of the MCU. Additional study of surface and interfacial tension is recommended. This tool may also offer economical and rapid process diagnostics for future operations
Narrow-band tunable terahertz emission from ferrimagnetic Mn3-xGa thin films
Narrow-band terahertz emission from coherently excited spin precession in metallic ferrimagnetic Mn3-xGa Heusler alloy nanofilms has been observed. The efficiency of the emission, per nanometer film thickness, is comparable or higher than that of classical laser-driven terahertz sources based on optical rectification. The center frequency of the emission from the films can be tuned precisely via the film composition in the range of 0.20-0.35 THz, making this type of metallic film a candidate for efficient on-chip terahertz emitters. Terahertz emission spectroscopy is furthermore shown to be a sensitive probe of magnetic properties of ultra-thin films. Published by AIP Publishing
Recommended from our members
A multicentre, randomised controlled trial to compare the clinical and cost-effectiveness of Lee Silverman Voice Treatment versus standard NHS Speech and Language Therapy versus control in Parkinson’s disease: a study protocol for a randomised controlled trial
Abstract: Background: Parkinson’s disease (PD) affects approximately 145,519 people in the UK. Speech impairments are common with a reported prevalence of 68%, which increase physical and mental demands during conversation, reliance on family and/or carers, and the likelihood of social withdrawal reducing quality of life. In the UK, two approaches to Speech and Language Therapy (SLT) intervention are commonly available: National Health Service (NHS) SLT or Lee Silverman Voice Treatment (LSVT LOUD®). NHS SLT is tailored to the individuals’ needs per local practice typically consisting of six to eight weekly sessions; LSVT LOUD® comprises 16 sessions of individual treatment with home-based practice over 4 weeks. The evidence-base for their effectiveness is inconclusive. Methods/design: PD COMM is a phase III, multicentre, three-arm, unblinded, randomised controlled trial. Five hundred and forty-six people with idiopathic PD, reporting speech or voice problems will be enrolled. We will exclude those with a diagnosis of dementia, laryngeal pathology or those who have received SLT for speech problems in the previous 2 years. Following informed consent and completion of baseline assessments, participants will be randomised in a 1:1:1 ratio to no-intervention control, NHS SLT or LSVT LOUD® via a central computer-generated programme, using a minimisation procedure with a random element, to ensure allocation concealment. Participants randomised to the intervention groups will start treatment within 4 (NHS SLT) or 7 (LSVT LOUD®) weeks of randomisation. Primary outcome: Voice Handicap Index (VHI) total score at 3 months. Secondary outcomes include: VHI subscales, Parkinson’s Disease Questionnaire-39; Questionnaire on Acquired Speech Disorders; EuroQol-5D-5 L; ICECAP-O; resource utilisation; adverse events and carer quality of life. Mixed-methods process and health economic evaluations will take place alongside the trial. Assessments will be completed before randomisation and at 3, 6 and 12 months after randomisation. The trial started in December 2015 and will run for 77 months. Recruitment will take place in approximately 42 sites around the UK. Discussion: The trial will test the hypothesis that SLT is effective for the treatment of speech or voice problems in people with PD compared to no SLT. It will further test whether NHS SLT or LSVT LOUD® provide greater benefit and determine the cost-effectiveness of both interventions. Trial registration: International Standard Randomised Controlled Trials Number (ISRCTN) Registry, ID: 12421382. Registered on 18 April 2016
Recommended from our members
A multicentre, randomised controlled trial to compare the clinical and cost-effectiveness of Lee Silverman Voice Treatment versus standard NHS Speech and Language Therapy versus control in Parkinson’s disease: a study protocol for a randomised controlled trial
Abstract: Background: Parkinson’s disease (PD) affects approximately 145,519 people in the UK. Speech impairments are common with a reported prevalence of 68%, which increase physical and mental demands during conversation, reliance on family and/or carers, and the likelihood of social withdrawal reducing quality of life. In the UK, two approaches to Speech and Language Therapy (SLT) intervention are commonly available: National Health Service (NHS) SLT or Lee Silverman Voice Treatment (LSVT LOUD®). NHS SLT is tailored to the individuals’ needs per local practice typically consisting of six to eight weekly sessions; LSVT LOUD® comprises 16 sessions of individual treatment with home-based practice over 4 weeks. The evidence-base for their effectiveness is inconclusive. Methods/design: PD COMM is a phase III, multicentre, three-arm, unblinded, randomised controlled trial. Five hundred and forty-six people with idiopathic PD, reporting speech or voice problems will be enrolled. We will exclude those with a diagnosis of dementia, laryngeal pathology or those who have received SLT for speech problems in the previous 2 years. Following informed consent and completion of baseline assessments, participants will be randomised in a 1:1:1 ratio to no-intervention control, NHS SLT or LSVT LOUD® via a central computer-generated programme, using a minimisation procedure with a random element, to ensure allocation concealment. Participants randomised to the intervention groups will start treatment within 4 (NHS SLT) or 7 (LSVT LOUD®) weeks of randomisation. Primary outcome: Voice Handicap Index (VHI) total score at 3 months. Secondary outcomes include: VHI subscales, Parkinson’s Disease Questionnaire-39; Questionnaire on Acquired Speech Disorders; EuroQol-5D-5 L; ICECAP-O; resource utilisation; adverse events and carer quality of life. Mixed-methods process and health economic evaluations will take place alongside the trial. Assessments will be completed before randomisation and at 3, 6 and 12 months after randomisation. The trial started in December 2015 and will run for 77 months. Recruitment will take place in approximately 42 sites around the UK. Discussion: The trial will test the hypothesis that SLT is effective for the treatment of speech or voice problems in people with PD compared to no SLT. It will further test whether NHS SLT or LSVT LOUD® provide greater benefit and determine the cost-effectiveness of both interventions. Trial registration: International Standard Randomised Controlled Trials Number (ISRCTN) Registry, ID: 12421382. Registered on 18 April 2016