82 research outputs found

    Assessment of load capacity of railway RC slab spans with reinforcement losses

    Get PDF
    Framework Programme of European Union - Project “Sustainable Bridges – Assessment for Future Traffic Demands and Longer Lives”, contract No TIP3-CT-2003-00165

    Concrete railway bridges : taxonomy of degradation mechanisms and damages identified by NDT methods

    Get PDF
    The aim of this work is creating basis for unified and more objective assessment of bridge condition and for application of expert tools in evaluation process. The degradation processes and the relevant NDT techniques are presented on the background of the causes and the effects of these processes, taking into account: factors which influence degradation processes, mechanisms of degradation and effects of degradation with proposed methodology of identification and classification of the damages in concrete bridge structures. The proposed uniform taxonomy of degradation processes of the concrete railway bridges as well as presented analysis of the available NDT methods can be applied in evaluation of bridge condition and in modelling of structure lifetime.Framework Programme of European Union - "Sustainable Bridges – Assessment for Future Traffic Demands and Longer Lives” nº TIP3-CT-2003-001653

    Binuclear Rhodium(II) Complexes With Selective Antibacterial Activity

    Get PDF
    Binuclear rhodium(II) complexes [Rh2Cl2(μ-OOCR)2(N-N)2] {R = H, Me; N-N = 2,2'-bipyridine (bpy), 1,10-phenanthroline (phen)} and [Rh2(μ-OOCR)2(N-N)2(H2O)2](RCOO)2 (R = Me, Et;) have been synthesized and their structure and properties have been studied by electronic, IR and 1H NMR spectroscopy. Antibacterial activity of these complexes against Escherichia coli and Staphylococcus aureus has been investigated. The most active antibacterial agents against E. coli were [Rh2Cl2(μ-OOCR)2(N-N)2] and [Rh2(μ-OOCR)2(N-N)2(H2O)2](RCOO)2 {R = H and Me} which were considerably more active than the appropriate nitrogen ligands. The complexes show low activity against S. aureus. The activity of the complexes [Rh2(OOCR)2(N-N)2(H2O)2](OOCR)2 against E. coli decreases in the series: R=H≅CH3>C2H5>C3H7≅C4H9. The reverse order was found in the case of S. aureus

    Relationship Between Anti-DFS70 Autoantibodies and Oxidative Stress

    Get PDF
    Background: The anti-DFS70 autoantibodies are one of the most commonly and widely described agent of unknown clinical significance, frequently detected in healthy individuals. It is not known whether the DFS70 autoantibodies are protective or pathogenic. One of the factors suspected of inducing the formation of anti-DFS70 antibodies is increased oxidative stress. We evaluated the coexistence of anti-DFS70 antibodies with selected markers of oxidative stress and investigated whether these antibodies could be considered as indirect markers of oxidative stress. Methods: The intensity of oxidative stress was measured in all samples via indices of free-radical damage to lipids and proteins such as total oxidant status (TOS), concentrations of lipid hydroperoxides (LPH), lipofuscin (LPS), and malondialdehyde (MDA). The parameters of the non-enzymatic antioxidant system, such as total antioxidant status (TAS) and uric acid concentration (UA), were also measured, as well as the activity of superoxide dismutase (SOD). Based on TOS and TAS values, the oxidative stress index (OSI) was calculated. All samples were also tested with indirect immunofluorescence assay (IFA) and 357 samples were selected for direct monospecific anti DFS70 enzyme-linked immunosorbent assay (ELISA) testing. Results: The anti-DFS70 antibodies were confirmed by ELISA test in 21.29% of samples. Compared with anti-DFS70 negative samples we observed 23% lower concentration of LPH (P =.038) and 11% lower concentration of UA (P =.005). TOS was 20% lower (P =.014). The activity of SOD was up to 5% higher (P =.037). The Pearson correlation showed weak negative correlation for LPH, UA, and TOS and a weak positive correlation for SOD activity. Conclusion: In samples positive for the anti-DFS70 antibody a decreased level of oxidative stress was observed, especially in the case of samples with a high antibody titer. Anti-DFS70 antibodies can be considered as an indirect marker of reduced oxidative stress or a marker indicating the recent intensification of antioxidant processes

    Aktywność niektórych pozakomórkowych hydrolaz mutantów Trichoderma viride po dwustopniowej mutagenezie

    No full text
    Five new mutants were obtained by UV irradiation of the wild T. viride C-1 strain, and two more by exposure to UV followed by NTG treatment. Exo-1 ,4- -glucanase, endo-1,4-glucanase, -glucosidase, xylanase and polygalacturonase activities were assaycd at various time intcrvals in supematants of post-culture fluids of shaker cultures. Extracellular cellulase activities of the two-stage mutants were several times higher than of the wild strain but similar or lower than of the single-stage (UV) mutant of T. viride C-1.W wyniku przeprowadzonej dwustopniowej mutagenezy (UV+ UV lub UV + NTG) szczepu T. viride C-1 uzyskano siedem nowych mutantów wykazujących największe strefy przejaśnienia wokół kolonii, podłóż selekcyjnych zawierających celulozę. Mutanty porównano pod względem ich uzdolnień do syntezy endoglukanaz, egzoglukanaz, -glukozydaz oraz enzymów towarzyszących, takich jak ksylanazy i poligalakturonazy. W tym celu mutanty i szczep dziki hodowano na pożywce mineralnej Saundersa z dodatkiem sproszkowanej celulozy (2%), wysłodków buraczanych (2%), ekstraktu drożdżowego (0,5%), zarodków pszennych (0,5%) na wstrząsarkach rotacyjnych w 28-30ºC. Zaobserwowano zmiany w dynamice wytwarzania pozakomórkowych hydrolaz i poziomic ich aktywności. Większość mutantów wykazała kilkukrotne zwiększenie poziomu aktywności badanych celulaz, w porównaniu ze szczepem dzikim T. viride C-1 tj. egzoglukanaz - 1,5-3,4-krotne, endoglukanaz - 2,1-5,8-krotne, -glukozydaz - 1,2-2,7-krotne, natomiast zbliżony lub niższy poziom tych aktywności w porównaniu z UV mutantem M4-4 (po jednostopniowej mutacji). Indukcja UV mutantów o podwyższonej aktywności celulolitycznej (T. viride M4-4) ujemnie wpłynęła na poziom aktywności. W przypadku natomiast ksylanaz osiągnięto zwiększenie aktywności o 50%. Po dwustopniowej mutacji większość pozyskanych mutantów charakteryzowała się zbliżonym poziomem aktywności tych enzymów do UV mutanta T. viride M4-4

    Combustion kinetics of sewage sludge under oxygen-enriched atmosphere

    No full text
    Przedstawiono wyniki badań kinetyki spalania komunalnych osadów ściekowych w modyfikowanej atmosferze, realizowanych z zastosowaniem metodyki opartej na termograwimetrii. Badania termograwimetryczne przeprowadzono jako dynamiczne (nieizotermiczne) i statyczne (quasi-izotermiczne). Badania prowadzono w pięciu atmosferach gazowych, przygotowanych na bazie tlenu oraz ditlenku węgla. Udział tlenu w mieszance stanowił odpowiednio: 20, 40, 60, 80 oraz 100% obj. Eksperyment prowadzony był w zakresie temperatur 873 ÷ 1273 K. Otrzymane doświadczalnie wyniki, w oparciu o przyjęty model kurczącego się rdzenia (SCM), pozwoliły wyznaczyć podstawowe parametry kinetyczne: rząd reakcji n, współczynnik przedeksponencjalny K0, energię aktywacji Ea, oraz przeprowadzić szacowanie reaktywności osadów w szerokim zakresie parametrów. Wykazano przy tym znaczący wpływ stężenia tlenu na pozorną szybkość reakcji, w przeciwieństwie do wpływu temperatury, który okazał się nieznaczny. Zaobserwowano znaczący wpływ współczynnika szybkości nagrzewania na termiczną dekompozycję osadów ściekowych w tej samej atmosferze. Maksymalną szybkość ubytku masy próbki odnotowano przy największym współczynniku nagrzewu. Nie zaobserwowano natomiast znaczącego przesunięcia temperaturowego w kierunku wyższych wartości temperatur wraz ze wzrostem współczynnika nagrzewu, co ma miejsce przy wzroście stężenia tlenu.The paper presents the results of combustion kinetics of municipal sewage sludge in a modified atmospheres. The studies were investigated by a thermogravimetric analysis. Thermogravimetric tests were carried out as a dynamic (non-isothermal) and static (quasi-isothermal). Tests was conducted in five gaseous atmospheres prepared from oxygen and carbon dioxide. Participation of oxygen in the mixture were as following: 20, 40, 60, 80 and 100% vol. The experiment was conducted in the temperature range 873 ÷ 1273 K. Experimentally obtained results based on the model of the shrinking core (SCM), helped establish the basic kinetic parameters such as: reaction order n, factor K0 and activation energy Ea. The values of activation energy Ea and K0 were, respectively: 45.57 kJ/mol (10.9 kcal/mol) and 0.0127 mg/m2sPa. Values of activation energy Ea of sewage sludge combustion in O2/CO2 atmosphere in the temperature range 873 ÷ 1273 K show that the limiting factor of combustion is the diffusion of oxygen, therefore the combustion reaction takes place here only in the outer layer of the unreacted core. The experimental studies in a wide range of process parameters such as temperature and partial pressure of oxygen helped to create an array of apparent reaction rates as a function of temperature and oxygen concentration in the gas reaction. It has been shown the significant effect of oxygen on the apparent reaction rate, in contrast to the effect of temperature, which was insignificant. The impact of the heating rate on sludge combustion was also investigated. For this purpose, sludge was heated from ambient temperature to a 1000°C at a four different heating rates 10, 20 and 40 K min-1 in the ° variable O2/CO2 atmosphere. With increasing heating rates TG curves get closer and closer to each other. Percentage weight loss was about 65.26% at a heating rate 10 K min-1. At 40 K min-1 percentage loss was 65.97%. From that it could be stated the the heating rate play no role in the loss of material mass. With increasing heating rate is not observed a substantial shift of the peak temperature of the sample weight loss

    Application of sludge and environmental safety

    No full text
    W związku ze zbliżającym się zakazem kierowania osadów ściekowych na składowiska odpadów, powracają kwestie związane z ich bezpiecznym dla środowiska stosowaniem. Do niedawna sądzono, że największy problem obecnych w osadach zanieczyszczeń chemicznych stanowią pierwiastki śladowe (głównie metale ciężkie) oraz trwałe zanieczyszczenia organiczne (WWA, PCB). Ostatnie badania wskazują jednak na szereg nowych niebezpieczeństw. Należą do nich przede wszystkim tzw. Pharmaceuticals and Personal Care Products (PPCPs): farmaceutyki (antybiotyki, środki przeciwzapalne i przeciwbólowe), produkty higieny osobistej (np. triklosan) oraz nanocząstki (np. Ag, Fe, Cu, TiO2).In view of the upcoming ban on sending sludge to landfills, the question of its environmentally safe application become more importnant. Until recently, it was believed that the biggest problem of chemical contaminants present in the sludge is posed by trace elements (mainly heavy metals) and persistent organic pollutants (PHA, PCB). However, the latest research indicates a number of new hazards. They include mainly PPCPs, i.e. Pharmaceuticals (antibiotics, anti-inflammatory and analgesic agents), Personal Care Products (e.g. triclosan) and nanoparticles (e.g. Ag, Fe, Cu, TiO2)

    Investigation of the effectiveness of protection against the effects of bearing currents using the short-circuiting rings

    No full text
    The flow of bearing currents in electrical machines is a known, practical problem. Each type electrical machinery is exposed to the existence of the shaft voltage which cause current to flow through the bearing. Currently, the most common problem of this is seen in the operation of induction machines. A good way of protecting the bearings seems to be a short-circuit between stator and rotor. In this situation a potential of the shaft is close to zero relative to the potential of stator (usually grounded) and the shaft current will flow by short-circuit element. In the proposed article, the authors would like to present the results of the assessment of the effectiveness of the special short circuiting rings, which are used to protect the bearings from the effects of the current flow.Przepływ prądów łożyskowych w maszynach elektrycznych jest znanym od lat problemem eksploatacyjnym. Każdy rodzaj maszyn elektrycznych jest narażony na występowanie napięć wałowych i przepływ prądu przez łożyska. Obecnie najczęściej problem taki jest zauważany podczas eksploatacji maszyn indukcyjnych. Dobrym sposobem ochrony łożysk wydaje się być ich zwarcie w taki sposób, aby prąd płynął poza łożyskiem i potencjał wału względem obudowy (najczęściej uziemionej) był bliski zera. W proponowanym artykule autorzy chcieliby przedstawić wyniki oceny skuteczności działania specjalnych pierścieni zwierających, których zadaniem jest właśnie ochrona łożysk przed skutkami przepływu prądu

    Investigation of the effectiveness of protection against the effects of bearing currents using the short-circuiting rings

    No full text
    Przepływ prądów łożyskowych w maszynach elektrycznych jest znanym od lat problemem eksploatacyjnym. Każdy rodzaj maszyn elektrycznych jest narażony na występowanie napięć wałowych i przepływ prądu przez łożyska. Obecnie najczęściej problem taki jest zauważany podczas eksploatacji maszyn indukcyjnych. Dobrym sposobem ochrony łożysk wydaje się być ich zwarcie w taki sposób, aby prąd płynął poza łożyskiem i potencjał wału względem obudowy (najczęściej uziemionej) był bliski zera. W proponowanym artykule autorzy chcieliby przedstawić wyniki oceny skuteczności działania specjalnych pierścieni zwierających, których zadaniem jest właśnie ochrona łożysk przed skutkami przepływu prądu.The flow of bearing currents in electrical machines is a known, practical problem. Each type electrical machinery is exposed to the existence of the shaft voltage which cause current to flow through the bearing. Currently, the most common problem of this is seen in the operation of induction machines. A good way of protecting the bearings seems to be a short-circuit between stator and rotor. In this situation a potential of the shaft is close to zero relative to the potential of stator (usually grounded) and the shaft current will flow by short-circuit element. In the proposed article, the authors would like to present the results of the assessment of the effectiveness of the special short circuiting rings, which are used to protect the bearings from the effects of the current flow

    Pozyskiwanie lotnych kwasów tłuszczowych w procesie stabilizacji beztlenowej osadów pochodzących z przemysłu spożywczego

    No full text
    The conventional process of oxygen-free stabilization is time-consuming and has low effectiveness. The literature review made, as well as the original studies carried out suggest that the ultrasonic conditioning provides a new way of shortening the duration and increasing the effectiveness of the process of oxygen-free stabilization of sludges forming in the process of treatment of both domestic sewage and industrial liquid wastes. Achieving the considerable increase in the degree of digestion during the oxygen-free stabilization of sludge conditioned with the ultrasonic (US) field compared with the reduction of organic matter noted during the oxygen-free stabilization of non-conditioned sludge results from the combined action of both biological hydrolysis, being the first stage of the process, and the phenomenon of sonochemical hydrolysis taking place during the treatment process. Subjecting sludge to conditioning by the method investigated contributes to a considerable intensification of the hydrolysis phase, as reflected by the increase in the production rate and concentration of volatile fatty acids noted in the successive days of conducting the oxygen-free stabilization process, which determines directly the increase of digestion effectiveness, ie the degree of sludge digestion and the unit production of biogas. Excessive active sludge formed as a result of the treatment of a mixture of domestic sewage and industrial liquid wastes generated in a plant manufacturing juices and beverages was subjected to oxygen-free stabilization under static conditions. The process was conducted both in laboratory flasks, constituting fermentation chamber models, as well as in a sludge fermentation chamber by Applicon.Konwencjonalny proces stabilizacji beztlenowej jest często czasochłonny i ma niską efektywność. Dokonany przegląd literaturowy, jak również przeprowadzone badania własne sugerują, że ultradźwiękowe kondycjonowanie stanowi nową drogę do skrócenia czasu oraz zwiększenia efektywności procesu stabilizacji beztlenowej osadów, powstających zarówno w procesie oczyszczania ścieków bytowo-gospodarczych, jak i przemysłowych. Uzyskanie znacznego wzrostu stopnia przefermentowania podczas stabilizacji beztlenowej osadów kondycjonowanych polem ultradźwiękowym (UD), w odniesieniu do redukcji substancji organicznych odnotowanych podczas stabilizacji beztlenowej osadów niepreparowanych, wynika z kombinacji działania zarówno hydrolizy biologicznej, stanowiącej pierwszy etap procesu, jak również zjawiska hydrolizy sonochemicznej, mającej miejsce podczas procesu preparowania. Poddanie osadów kondycjonowaniu badaną metodą wpływa na znaczną intensyfikację fazy hydrolizy, czego wyrazem był odnotowany w kolejnych dniach prowadzenia procesu stabilizacji beztlenowej wzrost tempa produkcji oraz stężenia lotnych kwasów tłuszczowych, warunkujący bezpośrednio zwiększenie efektywności fermentacji, tj. stopnia przefermentowania osadów oraz jednostkowej produkcji biogazu. Stabilizacji beztlenowej, w warunkach statycznych, poddano nadmierny osad czynny powstający w wyniku oczyszczania mieszaniny ścieków bytowo-gospodarczych oraz przemysłowych powstających na terenie zakładu produkującego soki oraz napoje. Proces prowadzono zarówno w kolbach laboratoryjnych, stanowiących modele komór fermentacyjnych, jak również w komorze fermentacyjnej firmy Applicon
    corecore