267 research outputs found
Resistance of superconducting nanowires connected to normal metal leads
We study experimentally the low temperature resistance of superconducting
nanowires connected to normal metal reservoirs. We find that a substantial
fraction of the nanowires is resistive, down to the lowest temperature
measured, indicative of an intrinsic boundary resistance due to the
Andreev-conversion of normal current to supercurrent. The results are
successfully analyzed in terms of the kinetic equations for diffusive
superconductors
Toxicity of statins on rat skeletal muscle mitochondria
Abstract.: We investigated mitochondrial toxicity of four lipophilic stains (cerivastatin, fluvastatin, atorvastatin, simvastatin) and one hydrophilic statin (pravastatin). In L6 cells (rat skeletal muscle cell line), the four lipophilic statins (100ÎĽmol/l) induced death in 27-49% of the cells. Pravastatin was not toxic up to 1mmol/l. Cerivastatin, fluvastatin and atorvastatin (100ÎĽmol/l) decreased the mitochondrial membrane potential by 49-65%, whereas simvastatin and pravastatin were less toxic. In isolated rat skeletal muscle mitochondria, all statins, except pravastatin, decreased glutamate-driven state 3 respiration and respiratory control ratio. Beta-oxidation was decreased by 88-96% in the presence of 100ÎĽmol/l of the lipophilic statins, but only at higher concentrations by pravastatin. Mitochondrial swelling, cytochrome c release and DNA fragmentation was induced in L6 cells by the four lipophilic statins, but not by pravastatin. Lipophilic statins impair the function of skeletal muscle mitochondria, whereas the hydrophilic pravastatin is significantly less toxi
Hepatic effects of Cimicifuga racemosa extract in vivo and in vitro
Abstract.: Extracts of Cimicifuga racemosa are used frequently for menopausal complaints. Cimicifuga is well tolerated but can occasionally cause liver injury. To assess hepatotoxicity of cimicifuga in more detail, ethanolic C. racemosa extract was administered orally to rats, and liver sections were analyzed by electron microscopy. Tests for cytotoxicity, mitochondrial toxicity and apoptosis/necrosis were performed using HepG2 cells. Mitochondrial toxicity was studied using isolated rat liver mitochondria. Microvesicular steatosis was found in rats treated with > 500 μg/kg body weight cimicifuga extract. In vitro, cytotoxicity was apparent at concentrations ≥ 75 μg/mL, and mitochondrial β-oxidation was impaired at concentrations ≥ 10 μg/mL. The mitochondrial membrane potential was decreased at concentrations ≥ 100 μg/mL, and oxidative phosphorylation was impaired at concentrations ≥ 300 μg/mL. The mechanism of cell death was predominantly apoptosis. C. racemosa exerts toxicity in vivo and in vitro, eventually resulting in apoptotic cell death. The results are compatible with idiosyncratic hepatotoxicity as observed in patients treated with cimicifuga extract
Methotrexate area under the curve is an important outcome predictor in patients with primary CNS lymphoma: A pharmacokinetic–pharmacodynamic analysis from the IELSG no. 20 trial
This analysis was initiated to define the predictive value of the area under the curve of high-dose methotrexate (AUC(HD-MTX)) in patients with primary central nervous system lymphoma (PCNSL).; We included 55 patients with PCNSL and available pharmacokinetic (PK) data from the International Extranodal Lymphoma Study Group (IELSG) no. 20 trial, randomised to HD-MTX (n=30) or HD-MTX and high-dose cytarabine (HD-AraC) (n=25). Individual AUC(HD-MTX) from population PK analysis was tested on drug toxicity and clinical outcome using multivariate logistic regression analysis and Cox hazards modelling.; AUC(HD-MTX), the IELSG score and treatment group were significant predictors for treatment response (complete or partial) in the adjusted model. The AUC(HD-MTX) did not predict toxicity, with the exception of liver toxicity and neutropaenia. A high AUC(HD-MTX) was associated with better event-free survival (EFS) (P=0.01) and overall survival (OAS) (P=0.02). Both the AUC(HD-MTX) and the IELSG score were significant predictors of EFS and OAS in the adjusted model, with a hazard ratio of 0.82 and 0.73, respectively, per 100 micromol l(-1) h(-1) increase in AUC(HD-MTX).; Individualised dosing of HD-MTX might have the potential to improve clinical outcome in patients with PCNSL, even when administered concurrently with HD-AraC. In the future, this could be carried out by using first-cycle PK modelling with determination of potential dose adaptations for later cycles using Bayesian analysis
FACT - Threshold prediction for higher duty cycle and improved scheduling
The First G-APD Cherenkov telescope (FACT) is the first telescope using
silicon photon detectors (G-APD aka. SiPM). The use of Silicon devices promise
a higher photon detection efficiency, more robustness and higher precision than
photo-multiplier tubes. Being operated during different light-conditions, the
threshold settings of a Cherenkov telescope have to be adapted to feature the
lowest possible threshold but also an efficient suppression of triggers from
night-sky background photons. Usually this threshold is set either by
experience or a mini-ratescan. Since the measured current through the sensors
is directly correlated with the noise level, the current can be used to set the
best threshold at any time. Due to the correlation between the physical
threshold and the final energy threshold, the current can also be used as a
measure for the energy threshold of any observation. This presentation
introduces a method which uses the properties of the moon and the source
position to predict the currents and the corresponding energy threshold for
every upcoming observation allowing to adapt the observation schedule
accordingly
FACT - Long-term stability and observations during strong Moon light
The First G-APD Cherenkov Telescope (FACT) is the first Cherenkov telescope
equipped with a camera made of silicon photon detectors (G-APD aka. SiPM).
Since October 2011, it is regularly taking data on the Canary Island of La
Palma. G-APDs are ideal detectors for Cherenkov telescopes as they are robust
and stable. Furthermore, the insensitivity of G-APDs towards strong ambient
light allows to conduct observations during bright Moon and twilight. This gain
in observation time is essential for the long-term monitoring of bright TeV
blazars. During the commissioning phase, hundreds of hours of data (including
data from the the Crab Nebula) were taken in order to understand the
performance and sensitivity of the instrument. The data cover a wide range of
observation conditions including different weather conditions, different zenith
angles and different light conditions (ranging from dark night to direct full
Moon). We use a new parmetrisation of the Moon light background to enhance our
scheduling and to monitor the atmosphere. With the data from 1.5 years, the
long-term stability and the performance of the camera during Moon light is
studied and compared to that achieved with photomultiplier tubes so far.Comment: 3 pages, 3 figures, FACT Contribution to the 33rd International
Cosmic Ray Conference (ICRC), Rio de Janeir
FACT - Long-term Monitoring of Bright TeV-Blazars
Since October 2011, the First G-APD Cherenkov Telescope (FACT) is operated
successfully on the Canary Island of La Palma. Apart from the proof of
principle for the use of G-APDs in Cherenkov telescopes, the major goal of the
project is the dedicated long-term monitoring of a small sample of bright TeV
blazars. The unique properties of G-APDs permit stable observations also during
strong moon light. Thus a superior sampling density is provided on time scales
at which the blazar variability amplitudes are expected to be largest, as
exemplified by the spectacular variations of Mrk 501 observed in June 2012.
While still in commissioning, FACT monitored bright blazars like Mrk 421 and
Mrk 501 during the past 1.5 years so far. Preliminary results including the Mrk
501 flare from June 2012 will be presented.Comment: 4 pages, 4 figures, presented at the 33rd ICRC (2013
FACT - How stable are the silicon photon detectors?
The First G-APD Cherenkov telescope (FACT) is the first telescope using
silicon photon detectors (G-APD aka. SiPM). The use of Silicon devices promise
a higher photon detection efficiency, more robustness and higher precision than
photo-multiplier tubes. Since the properties of G-APDs depend on auxiliary
parameters like temperature, a feedback system adapting the applied voltage
accordingly is mandatory.
In this presentation, the feedback system, developed and in operation for
FACT, is presented. Using the extraction of a single photon-equivalent (pe)
spectrum as a reference, it can be proven that the sensors can be operated with
very high precision. The extraction of the single-pe, its spectrum up to
10\,pe, its properties and their precision, as well as their long-term behavior
during operation are discussed. As a by product a single pulse template is
obtained. It is shown that with the presented method, an additional external
calibration device can be omitted. The presented method is essential for the
application of G-APDs in future projects in Cherenkov astronomy and is supposed
to result in a more stable and precise operation than possible with
photo-multiplier tubes
FACT -- the First Cherenkov Telescope using a G-APD Camera for TeV Gamma-ray Astronomy (HEAD 2010)
Geiger-mode Avalanche Photodiodes (G-APD) bear the potential to significantly
improve the sensitivity of Imaging Air Cherenkov Telescopes (IACT). We are
currently building the First G-APD Cherenkov Telescope (FACT) by refurbishing
an old IACT with a mirror area of 9.5 square meters and construct a new, fine
pixelized camera using novel G-APDs. The main goal is to evaluate the
performance of a complete system by observing very high energy gamma-rays from
the Crab Nebula. This is an important field test to check the feasibility of
G-APD-based cameras to replace at some time the PMT-based cameras of planned
future IACTs like AGIS and CTA. In this article, we present the basic design of
such a camera as well as some important details to be taken into account.Comment: Poster shown at HEAD 2010, Big Island, Hawaii, March 1-4, 201
- …