3 research outputs found

    Correlation between the functional impairment of bone marrow-derived circulating progenitor cells and the extend of coronary artery disease

    No full text
    Abstract Background Bone marrow-derived circulating progenitor cells (BM-CPCs) in patients with coronary heart disease are impaired with respect to number and functional activity. However, the relation between the functional activity of BM-CPCs and the number of diseased coronary arteries is yet not known. We analyzed the influence of the number of diseased coronary arteries on the functional activity of BM-CPCs in peripheral blood (PB) in patients with ischemic heart disease (IHD). Methods The functional activity of BM-CPCs was measured by migration assay and colony forming unit in 120 patients with coronary 1 vessel (IHD1, n = 40), coronary 2 vessel (IHD2, n = 40), coronary 3 vessel disease (IHD3, n = 40) and in a control group of healthy subjects (n = 40). There was no significant difference of the total number of cardiovascular risk factors between IHD groups, beside diabetes mellitus (DM), which was significantly higher in IHD3 group compared to IHD2 and IHD1. Results The colony-forming capacity (CFU-E: p  Conclusions The functional activity of BM-CPCs in PB is impaired in patients with IHD. This impairment increases with the number of diseased coronary arteries. Moreover, the regenerative capacity of BM-CPCs in ischemic tissue further declines in IHD patients with DM. Furthermore, monitoring the level of BM-CPCs in PB may provide new insights in patients with IHD.</p

    Predictive factors for pacemaker requirement after transcatheter aortic valve implantation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Transcatheter aortic valve implantation (TAVI) has been established as a treatment option for inoperable patients with symptomatic aortic valve stenosis. However, patients suffer frequently from conduction disturbances after TAVI.</p> <p>Methods</p> <p>Baseline, procedural as well as surface and intracardiac ECG parameters were evaluated for patients treated with TAVI and a comparison between patients requiring pacemaker with those not suffering from relevant conduction disorders were done.</p> <p>Results</p> <p>TAVI was successfully in all patients (n=45). Baseline surface and intracardiac ECG recording revealed longer PQ (197.1±51.2 msec versus 154.1±32.1 msec; p<0.001), longer AH (153.6±43.4 msec versus 116.1±31.2 msec; p<0.001) and HV interval (81.7±17.8 msec versus 56.8±8.5 msec; p<0.001) in patients with need for a pacemaker (n=23) versus control group (n=22); furthermore, 7-day follow-up analysis showed a higher prevalence of new left bundle branch block (LBBB) (87.0% versus 31.9%; p<0.001). Multivariate analysis revealed that only new LBBB, QRS duration >120 msec and a PQ interval >200 msec immediately (within 60 minutes) after implantation of the aortic valve were predictors for high-grade (type II second-degree and third-degree) AV block. Other clinical parameters as well as baseline electrocardiographic parameters had no impact on critical conduction delay.</p> <p>Conclusion</p> <p>Cardiac conduction disturbances are common after TAVI. The need for pacing after TAVI is predictable by surface ECG evaluation immediately (within 60 minutes) after the procedure.</p
    corecore