4 research outputs found

    The cost of a single concussion in American high school football: A retrospective cohort study

    Get PDF
    Aim: The potential financial burden of American football-related concussions (FRC) is unknown. Our objective was to describe the healthcare costs associated with an FRC and determine factors associated with increased costs. Methodology/results: A retrospective cohort study of concussed high school football players presenting between November 2017 and March 2020 was undertaken; 144 male high school football players were included. Total costs were about 115,000,foranaveragedirecthealthcarecostof115,000, for an average direct healthcare cost of 800.10/concussion. Visiting the emergency department (Ī² = 502.29, 95% CI: 105.79-898.61; p = 0.01), the initial post-concussion symptom scale score (Ī² = 0.39, 95% CI: 0.11-0.66; p = 0.01) and a post-concussion syndrome diagnosis (Ī² = 670.37, 95% CI: 98.96-1241.79; p = 0.02) were each independently associated with total costs. Conclusion: A granular understanding of cost-driving factors associated with FRC is the first step in understanding the cost-effectiveness of prevention and treatment methods

    Multiā€shot acquisitions for stimulusā€evoked spinal cord BOLD fMRI

    No full text
    PURPOSE: To demonstrate the feasibility of 3D multi-shot magnetic resonance imaging acquisitions for stimulus-evoked blood oxygenation level dependent (BOLD) functional magnetic resonance imaging (fMRI) in the human spinal cord in vivo. METHODS: Two fMRI studies were performed at 3 Tesla. The first study was a hypercapnic gas challenge where data were acquired from healthy volunteers using a multi-shot 3D fast field echo (FFE) sequence as well as single-shot multi-slice echo-planar imaging (EPI). In the second study, another cohort of healthy volunteers performed an upper extremity motor task while fMRI data were acquired using a 3D multi-shot acquisition. RESULTS: Both 2D-EPI and 3D-FFE were shown to be sensitive to BOLD signal changes in the cervical spinal cord, and had comparable contrast-to-noise ratios in gray matter. FFE exhibited much less signal drop-out and weaker geometric distortions compared to EPI. In the motor paradigm study, the mean number of active voxels was highest in the ventral gray matter horns ipsilateral to the side of the task and at the spinal level associated with innervation of finger extensors. CONCLUSION: Highly multi-shot acquisition sequences such as 3D-FFE are well suited for stimulus-evoked spinal cord BOLD fMRI

    Multiā€shot acquisitions for stimulusā€evoked spinal cord BOLD fMRI

    No full text
    PURPOSE: To demonstrate the feasibility of 3D multi-shot magnetic resonance imaging acquisitions for stimulus-evoked blood oxygenation level dependent (BOLD) functional magnetic resonance imaging (fMRI) in the human spinal cord in vivo. METHODS: Two fMRI studies were performed at 3 Tesla. The first study was a hypercapnic gas challenge where data were acquired from healthy volunteers using a multi-shot 3D fast field echo (FFE) sequence as well as single-shot multi-slice echo-planar imaging (EPI). In the second study, another cohort of healthy volunteers performed an upper extremity motor task while fMRI data were acquired using a 3D multi-shot acquisition. RESULTS: Both 2D-EPI and 3D-FFE were shown to be sensitive to BOLD signal changes in the cervical spinal cord, and had comparable contrast-to-noise ratios in gray matter. FFE exhibited much less signal drop-out and weaker geometric distortions compared to EPI. In the motor paradigm study, the mean number of active voxels was highest in the ventral gray matter horns ipsilateral to the side of the task and at the spinal level associated with innervation of finger extensors. CONCLUSION: Highly multi-shot acquisition sequences such as 3D-FFE are well suited for stimulus-evoked spinal cord BOLD fMRI

    Evaluating single-point quantitative magnetization transfer in the cervical spinal cord: Application to multiple sclerosis

    No full text
    Spinal cord (SC) damage is linked to clinical deficits in patients with multiple sclerosis (MS), however, conventional MRI methods are not specific to the underlying macromolecular tissue changes that may precede overt lesion detection. Single-point quantitative magnetization transfer (qMT) is a method that can provide high-resolution indices sensitive to underlying macromolecular composition in a clinically feasible scan time by reducing the number of MT-weighted acquisitions and utilizing a two-pool model constrained by empirically determined constants. As the single-point qMT method relies on a priori constraints, it has not been employed extensively in patients, where these constraints may vary, and thus, the biases inherent in this model have not been evaluated in a patient cohort. We, therefore, addressed the potential biases in the single point qMT model by acquiring qMT measurements in the cervical SC in patient and control cohorts and evaluated the differences between the control and patient-derived qMT constraints (kmf, T2fR1f, and T2m) for the single point model. We determined that the macromolecular to free pool size ratio (PSR) differences between the control and patient-derived constraints are not significant (p>0.149 in all cases). Additionally, the derived PSR for each cohort was compared, and we reported that the white matter PSR in healthy volunteers is significantly different from lesions (p<0.005) and normal appearing white matter (p<0.02) in all cases. The single point qMT method is thus a valuable method to quantitatively estimate white matter pathology in MS in a clinically feasible scan time. Keywords: Multiple sclerosis, Spinal cord, Normal appearing white matter, qMT, M
    corecore