62 research outputs found
Investigating the Influences of Task Demand and Reward on Cardiac Pre-Ejection Period (PEP) Reactivity During a Speech-in-Noise Task
Objectives: Effort investment during listening varies as a function of task demand and motivation. Several studies have manipulated both these factors to elicit and measure changes in effort associated with listening. The cardiac pre-ejection period (PEP) is a relatively novel measure in the field of cognitive hearing science. This measure, which reflects sympathetic nervous system activity on the heart, has previously been implemented during a tone discrimination task but not during a speech-in-noise task. Therefore, the primary goal of this study was to explore the influences of signal to noise ratio (SNR) and monetary reward level on PEP reactivity during a speech-in-noise task.
Design: Thirty-two participants with normal hearing (mean age = 22.22 years, SD = 3.03) were recruited at VU University Medical Center. Participants completed a Dutch speech-in-noise test with a single-interfering-talker masking noise. Six fixed SNRs, selected to span the entire psychometric performance curve, were presented in a block-wise fashion. Participants could earn a low (€0.20) or high (€5.00) reward by obtaining a score of ≥70% of words correct in each block. The authors analyzed PEP reactivity: the change in PEP measured during the task, relative to the baseline during rest. Two separate methods of PEP analysis were used, one including data from the whole task block and the other including data obtained during presentation of the target sentences only. After each block, participants rated their effort investment, performance, tendency to give up, and the perceived difficulty of the task. They also completed the need for recovery questionnaire and the reading span test, which are indices of additional factors (fatigue and working memory capacity, respectively) that are known to influence listening effort.
Results: Average sentence perception scores ranged from 2.73 to 91.62%, revealing a significant effect of SNR. In addition, an improvement in performance was elicited by the high, compared to the low reward level. A linear relationship between SNR and PEP reactivity was demonstrated: at the lower SNRs PEP reactivity was the most negative, indicating greater effort investment compared to the higher SNRs. The target stimuli method of PEP analysis was more sensitive to this effect than the block-wise method. Contrary to expectations, no significant impact of reward on PEP reactivity was found in the present dataset. Also, there was no physiological evidence that participants were disengaged, even when performance was poor. A significant correlation between need for recovery scores and average PEP reactivity was demonstrated, indicating that a lower need for recovery was associated with less effort investment.
Conclusions: This study successfully implemented the measurement of PEP during a standard speech-in-noise test and included two distinct methods of PEP analysis. The results revealed for the first time that PEP reactivity varies linearly with task demand during a speech-in-noise task, although the effect size was small. No effect of reward on PEP was demonstrated. Finally, participants with a higher need for recovery score invested more effort, as shown by average PEP reactivity, than those with a lower need for recovery score
The design of a project to assess bilateral versus unilateral hearing aid fitting
Binaural hearing provides advantages over monaural in several ways, particularly in difficult listening situations. For a person with bilateral hearing loss, the bilateral fitting of hearing aids thus seems like a natural choice. However, surprisingly few studies have been reported in which the additional benefit of bilateral versus unilateral hearing aid use has been investigated based on real-life experiences. Therefore, a project has been designed to address this issue and to find tools to identify people for whom the drawbacks would outweigh the advantages of bilateral fitting. A project following this design is likely to provide reliable evidence concerning differences in benefit between unilateral and bilateral fitting of hearing aids by evaluating correlations between entrance data and outcome measures and final preferences
Social observation increases the cardiovascular response of hearing-impaired listeners during a speech reception task
Certain cardiovascular measures allow for distinction between sympathetic and parasympathetic nervous system activity. Applied during listening, these measures may provide a novel and complementary insight into listening effort. To date, few studies have implemented cardiovascular measures of listening effort and seldom have these included hearing-impaired participants. These studies have generally measured changes in cardiovascular parameters while manipulating environmental factors, such as listening difficulty. Yet, listening effort is also known to be moderated by individual factors, including the importance of performing successfully. In this study, we aimed to manipulate success importance by adding observers to the traditional laboratory set-up. Twenty-nine hearing-impaired participants performed a speech reception task both alone and in the presence of two observers. Auditory stimuli consisted of Danish Hearing in Noise Test (HINT) sentences masked by four-talker babble. Sentences were delivered at two individually adapted signal-to-noise ratios, corresponding to 50 and 80% of sentences correct. We measured change scores, relative to baseline, of pre-ejection period, two indices of heart rate variability, heart rate and blood pressure (systolic, diastolic, and mean arterial pressure). After each condition, participants rated their effort investment, stress, tendency to give up and preference to change the situation to improve audibility. A multivariate analysis revealed that cardiovascular reactivity increased in the presence of the observers, compared to when the task was performed alone. More specifically, systolic, diastolic, and mean arterial blood pressure increased while observed. Interestingly, participants’ subjective ratings were sensitive only to intelligibility level, not the observation state. This study was the first to report results from a range of different cardiovascular variables measured from hearing-impaired participants during a speech reception task. Due to the timing of the observers’ presence, we were not able to conclusively attribute these physiological changes to being task related. Therefore, instead of representing listening effort, we suggest that the increased cardiovascular response detected during observation reveals increased physiological stress associated with potential evaluation
The contribution of visual information to the perception of speech in noise with and without informative temporal fine structure
Understanding what is said in demanding listening situations is assisted greatly by looking at the face of a talker. Previous studies have observed that normal-hearing listeners can benefit from this visual information when a talker’s voice is presented in background noise. These benefits have also been observed in quiet listening conditions in cochlear-implant users, whose device does not convey the informative temporal fine structure cues in speech, and when normal-hearing individuals listen to speech processed to remove these informative temporal fine structure cues. The current study (1) characterised the benefits of visual information when listening in background noise; and (2) used sine-wave vocoding to compare the size of the visual benefit when speech is presented with or without informative temporal fine structure. The accuracy with which normal-hearing individuals reported words in spoken sentences was assessed across three experiments. The availability of visual information and informative temporal fine structure cues was varied within and across the experiments. The results showed that visual benefit was observed using open- and closed-set tests of speech perception. The size of the benefit increased when informative temporal fine structure cues were removed. This finding suggests that visual information may play an important role in the ability of cochlear-implant users to understand speech in many everyday situations. Models of audio-visual integration were able to account for the additional benefit of visual information when speech was degraded and suggested that auditory and visual information was being integrated in a similar way in all conditions. The modelling results were consistent with the notion that audio-visual benefit is derived from the optimal combination of auditory and visual sensory cues
Auditory and cognitive training for cognition in adults with hearing loss: a systematic review and meta-analysis
This systematic review and meta-analysis examined the efficacy of auditory training and cognitive training to improve cognitive function in adults with hearing loss. A literature search of academic databases (e.g., MEDLINE, Scopus) and gray literature (e.g., OpenGrey) identified relevant articles published up to January 25, 2018. Randomized controlled trials (RCTs) or repeated measures designs were included. Outcome effects were computed as Hedge’s g and pooled using random-effects meta-analysis (PROSPERO: CRD42017076680). Nine studies, five auditory training, and four cognitive training met the inclusion criteria. Following auditory training, the pooled effect was small and statistically significant for both working memory (g = 0.21; 95% CI [0.05, 0.36]) and overall cognition (g = 0.19; 95% CI [0.07, 0.31]). Following cognitive training, the pooled effect for working memory was small and statistically significant (g = 0.34; 95% CI [0.16, 0.53]), and the pooled effect for overall cognition was large and significant (g = 1.03; 95% CI [0.41, 1.66]). However, this was dependent on the classification of training approach. Sensitivity analyses revealed no statistical difference between the effectiveness of auditory and cognitive training for improving cognition upon removal of a study that used a combined auditory–cognitive approach, which showed a very large effect. Overall certainty in the estimation of effect was “low” for auditory training and “very low” for cognitive training. High-quality RCTs are needed to determine which training stimuli will provide optimal conditions to improve cognition in adults with hearing loss
Ear-EEG allows extraction of neural responses in challenging listening scenarios: A future technology for hearing aids?
Advances in brain-computer interface research have recently empowered the development of wearable sensors to record mobile electroencephalography (EEG) as an unobtrusive and easy-to-use alternative to conventional scalp EEG. One such mobile solution is to record EEG from the ear canal, which has been validated for auditory steady state responses and discrete event related potentials (ERPs). However, it is still under discussion where to place recording and reference electrodes to capture best responses to auditory stimuli. Furthermore, the technology has not yet been tested and validated for ecologically relevant auditory stimuli such as speech. In this study, Ear-EEG and conventional scalp EEG were recorded simultaneously in a discrete-tone as well as a continuous-speech design. The discrete stimuli were applied in a dichotic oddball paradigm, while continuous stimuli were presented diotically as two simultaneous talkers. Cross-correlation of stimulus envelope and Ear-EEG was assessed as a measure of ongoing neural tracking. The extracted ERPs from Ear-EEG revealed typical auditory components yet depended critically on the reference electrode chosen. Reliable neural-tracking responses were extracted from the Ear-EEG for both paradigms, albeit weaker in amplitude than from scalp EEG. In conclusion, this study shows the feasibility of extracting relevant neural features from ear-canal-recorded "Ear-EEG", which might augment future hearing technology
- …