14 research outputs found
Dilation of the ascending aorta in Turner syndrome - a prospective cardiovascular magnetic resonance study
<p>Abstract</p> <p>Background</p> <p>The risk of aortic dissection is 100-fold increased in Turner syndrome (TS). Unfortunately, risk stratification is inadequate due to a lack of insight into the natural course of the syndrome-associated aortopathy. Therefore, this study aimed to prospectively assess aortic dimensions in TS.</p> <p>Methods</p> <p>Eighty adult TS patients were examined twice with a mean follow-up of 2.4 ± 0.4 years, and 67 healthy age and gender-matched controls were examined once. Aortic dimensions were measured at nine predefined positions using 3D, non-contrast and free-breathing cardiovascular magnetic resonance. Transthoracic echocardiography and 24-hour ambulatory blood pressure were also performed.</p> <p>Results</p> <p>At baseline, aortic diameters (body surface area indexed) were larger at all positions in TS. Aortic dilation was more prevalent at all positions excluding the distal transverse aortic arch. Aortic diameter increased in the aortic sinus, at the sinotubular junction and in the mid-ascending aorta with growth rates of 0.1 - 0.4 mm/year. Aortic diameters at all other positions were unchanged. The bicuspid aortic valve conferred higher aortic sinus growth rates (p < 0.05). No other predictors of aortic growth were identified.</p> <p>Conclusion</p> <p>A general aortopathy is present in TS with enlargement of the ascending aorta, which is accelerated in the presence of a bicuspid aortic valve.</p
Thoracic aortopathy in Turner syndrome and the influence of bicuspid aortic valves and blood pressure: a CMR study
<p>Abstract</p> <p>Background</p> <p/> <p>To investigate aortic dimensions in women with Turner syndrome (TS) in relation to aortic valve morphology, blood pressure, karyotype, and clinical characteristics.</p> <p>Methods and results</p> <p>A cross sectional study of 102 women with TS (mean age 37.7; 18-62 years) examined by cardiovascular magnetic resonance (CMR- successful in 95), echocardiography, and 24-hour ambulatory blood pressure. Aortic diameters were measured by CMR at 8 positions along the thoracic aorta. Twenty-four healthy females were recruited as controls. In TS, aortic dilatation was present at one or more positions in 22 (23%). Aortic diameter in women with TS and bicuspid aortic valve was significantly larger than in TS with tricuspid valves in both the ascending (32.4 ± 6.7 vs. 26.0 ± 4.4 mm; p < 0.001) and descending (21.4 ± 3.5 vs. 18.8 ± 2.4 mm; p < 0.001) aorta. Aortic diameter correlated to age (R = 0.2 - 0.5; p < 0.01), blood pressure (R = 0.4; p < 0.05), a history of coarctation (R = 0.3; p = 0.01) and bicuspid aortic valve (R = 0.2-0.5; p < 0.05). Body surface area only correlated with descending aortic diameter (R = 0.23; p = 0.024).</p> <p>Conclusions</p> <p/> <p>Aortic dilatation was present in 23% of adult TS women, where aortic valve morphology, age and blood pressure were major determinants of the aortic diameter.</p
Peripheral vascular surgery and magnetic resonance arteriography--a review
AbstractObjectives to review the current status of lower limb MRA. Design a literature review based predominantly on a MEDLINE database search of English-language publications from January 1991 to October 2000. Materials and methods twenty-eight articles, concerning non-enhanced MRA (13), gadolinium-enhanced MRA (14) or both (1), met the predefined requirement for quality. Results gadolinium-enhanced MRA (CE-MRA) seems to be more accurate, quicker and associated with fewer problems than non-enhanced (TOF) MRA. TOF-MRA has a sensitivity and specificity of 93% (range 64–100%) and 88% (range 57–100%) respectively, and CE-MRA presents values of 96% (range 71–100%) and 96% (63–100%), respectively, using conventional arteriography as the gold standard. Some articles report a substantial incidence of runoff vessels suitable for distal bypass visible on MRA but invisible on conventional arteriography. Gadolinium contrast is given intravenously and is generally well tolerated and has no known nephrotoxicity. Conclusion CE-MRA is accurate compared to conventional arteriography, has the potential to increase the limb salvage rate for selected patients, is non-invasive and well tolerated