1,265 research outputs found
Feasibility of OTR imaging of non-relativistic ions at GSI
The feasibility of using the optical transition radiation (OTR) generated as
a 11.4- to 300-MeV/\mu ion beam passes through a single metal conducting plane
for a minimally intercepting beam profile monitor for GSI/Darmstadt has been
evaluated for the first time. Although these are non-relativistic beams, their
beta and gamma values are similar to the 80-keV electron-beam imaging studies
previously done on the CTF3 injector. With anticipated beam intensities of 109
to 1011 particles per pulse and the predicted charge-squared dependence of OTR,
the ion charge state becomes a critical factor for photon production. The OTR
signal from the ion charge integrated over the video field time should be
comparable to or larger than the CTF3 electron case. These signal strengths
will allow a series of experiments to be done that should further elucidate the
working regime of this technique.Comment: 3 pp. Particle Accelerator, 24th Conference (PAC'11) 2011. 28 Mar - 1
Apr 2011. New York, US
Synchroscan streak camera imaging at a 15-MeV photoinjector with emittance exchange
At the Fermilab A0 photoinjector facility, bunch-length measurements of the
laser micropulse and the e-beam micropulse have been done in the past with a
fast single-sweep module of the Hamamatsu C5680 streak camera with an intrinsic
shot-to-shot trigger jitter of 10-20ps. We have upgraded the camera system with
the synchroscan module tuned to 81.25MHz to provide synchronous summing
capability with less than 1.5ps FWHM trigger jitter and a phase-locked delay
box to provide phase stability of ~1ps over 10s of minutes. These steps allowed
us to measure both the UV laser pulse train at 263nm and the e-beam via optical
transition radiation (OTR). Due to the low electron beam energies and OTR
signals, we typically summed over 50 micropulses with 0.25-1nC per micropulse.
The phase-locked delay box allowed us to assess chromatic temporal effects and
instigated another upgrade to an all-mirror input optics barrel. In addition,
we added a slow sweep horizontal deflection plug-in unit to provide dual-sweep
capability for the streak camera. We report on a series of measurements made
during the commissioning of these upgrades including bunch-length and phase
effects using the emittance exchange beamline and simultaneous imaging of a UV
drive laser component, OTR, and the 800nm diagnostics laser.Comment: 26 p
Upgrades of beam diagnostics in support of emittance-exchange experiments at the Fermilab A0 photoinjector
The possibility of using electron beam phase space manipulations to support a
free-electron laser accelerator design optimization has motivated our research.
An on-going program demonstrating the exchange of transverse horizontal and
longitudinal emittances at the Fermilab A0 photoinjector has benefited recently
from the upgrade of several of the key diagnostics stations. Accurate
measurements of these properties upstream and downstream of the exchanger
beamline are needed. Improvements in the screen resolution term and reduced
impact of the optical system's depth-of-focus by using YAG:Ce single crystals
normal to the beam direction will be described. The requirement to measure
small energy spreads (<10 keV) in the spectrometer and the exchange process
which resulted in bunch lengths less than 500 fs led to other diagnostics
performance adjustments and upgrades as well. A longitudinal to transverse
exchange example is also reported.Comment: 16 p
- …