29 research outputs found

    High Precision Hypernuclear Spectroscopy Study by the (e,e'K) Reaction

    Get PDF
    Jefferson Lab experiment E89009 is the first experiment to study hypernuclear spectroscopy by (e,e' K{sup +}) reaction. The 12 / LambdaB spectrum was observed from carbon target with the best energy resolution ever achieved from direct measurement of hypernuclear spectrum. The comparisons of the 12 / LambdaB spectrum with theoretical predictions were provided in terms of excitation strength and level separations. The overall excitation is in accord with theoretical calculations. The binding energies of p-shell and s-shell Lambda states were extracted. The photo-production cross section of the 12 / LambdaB ground state was also extracted. The experiment is also the pioneer in detecting scattered electrons at near zero degrees. The benefit and lessons learned from this method was also discussed

    Modeling the dosimetry of organ-at-risk in head and neck IMRT planning: An intertechnique and interinstitutional study

    Get PDF
    Purpose: To build a statistical model to quantitatively correlate the anatomic features of structures and the corresponding dose-volume histogram (DVH) of head and neck (HN) Tomotherapy (Tomo) plans. To study if the model built upon one intensity modulated radiation therapy (IMRT) technique (such as conventional Linac) can be used to predict anticipated organs-at-risk (OAR) DVH of patients treated with a different IMRT technique (such as Tomo). To study if the model built upon the clinical experience of one institution can be used to aid IMRT planning for another institution

    Establishing the feasibility of the dosimetric compliance criteria of RTOG 1308: phase III randomized trial comparing overall survival after photon versus proton radiochemotherapy for inoperable stage II-IIIB NSCLC.

    Get PDF
    BACKGROUND: To establish the feasibility of the dosimetric compliance criteria of the RTOG 1308 trial through testing against Intensity Modulation Radiation Therapy (IMRT) and Passive Scattering Proton Therapy (PSPT) plans. METHODS: Twenty-six lung IMRT and 26 proton PSPT plans were included in the study. Dose Volume Histograms (DVHs) for targets and normal structures were analyzed. The quality of IMRT plans was assessed using a knowledge-based engineering tool. RESULTS: Most of the RTOG 1308 dosimetric criteria were achieved. The deviation unacceptable rates were less than 10 % for most criteria; however, a deviation unacceptable rate of more than 20 % was computed for the planning target volume minimum dose compliance criterion. Dose parameters for the target volume were very close for the IMRT and PSPT plans. However, the PSPT plans led to lower dose values for normal structures. The dose parameters in which PSPT plans resulted in lower values than IMRT plans were: lung V5Gy (%) (34.4 in PSPT and 47.2 in IMRT); maximum spinal cord dose (31.7 Gy in PSPT and 43.5 Gy in IMRT); heart V5Gy (%) (19 in PSPT and 47 in IMRT); heart V30Gy (%) (11 in PSPT and 19 in IMRT); heart V45Gy (%) (7.8 in PSPT and 12.1 in IMRT); heart V50% (Gy) (7.1 in PSPT and 9.8 in IMRT) and mean heart dose (7.7 Gy in PSPT and 14.9 Gy in IMRT). CONCLUSIONS: The revised RTOG 1308 dosimetric compliance criteria are feasible and achievable

    Precision measurements of A1N in the deep inelastic regime

    Get PDF
    We have performed precision measurements of the double-spin virtual-photon asymmetry A1A1 on the neutron in the deep inelastic scattering regime, using an open-geometry, large-acceptance spectrometer and a longitudinally and transversely polarized 3He target. Our data cover a wide kinematic range 0.277≤x≤0.5480.277≤x≤0.548 at an average Q2Q2 value of 3.078 (GeV/c)2, doubling the available high-precision neutron data in this x range. We have combined our results with world data on proton targets to make a leading-order extraction of the ratio of polarized-to-unpolarized parton distribution functions for up quarks and for down quarks in the same kinematic range. Our data are consistent with a previous observation of anA1n zero crossing near x=0.5x=0.5. We find no evidence of a transition to a positive slope in(Δd+Δd¯)/(d+d¯) up to x=0.548x=0.548

    Generation of tissues outside the field of view (FOV) of radiation therapy simulation imaging based on machine learning and patient body outline (PBO)

    No full text
    Abstract Background It is not unusual to see some parts of tissues are excluded in the field of view of CT simulation images. A typical mitigation is to avoid beams entering the missing body parts at the cost of sub-optimal planning. Methods This study is to solve the problem by developing 3 methods, (1) deep learning (DL) mechanism for missing tissue generation, (2) using patient body outline (PBO) based on surface imaging, and (3) hybrid method combining DL and PBO. The DL model was built upon a Globally and Locally Consistent Image Completion to learn features by Convolutional Neural Networks-based inpainting, based on Generative Adversarial Network. The database used comprised 10,005 CT training slices of 322 lung cancer patients and 166 CT evaluation test slices of 15 patients. CT images were from the publicly available database of the Cancer Imaging Archive. Since existing data were used PBOs were acquired from the CT images. For evaluation, Structural Similarity Index Metric (SSIM), Root Mean Square Error (RMSE) and Peak signal-to-noise ratio (PSNR) were evaluated. For dosimetric validation, dynamic conformal arc plans were made with the ground truth images and images generated by the proposed method. Gamma analysis was conducted at relatively strict criteria of 1%/1 mm (dose difference/distance to agreement) and 2%/2 mm under three dose thresholds of 1%, 10% and 50% of the maximum dose in the plans made on the ground truth image sets. Results The average SSIM in generation part only was 0.06 at epoch 100 but reached 0.86 at epoch 1500. Accordingly, the average SSIM in the whole image also improved from 0.86 to 0.97. At epoch 1500, the average values of RMSE and PSNR in the whole image were 7.4 and 30.9, respectively. Gamma analysis showed excellent agreement with the hybrid method (equal to or higher than 96.6% of the mean of pass rates for all scenarios). Conclusions It was first demonstrated that missing tissues in simulation imaging could be generated with high similarity, and dosimetric limitation could be overcome. The benefit of this study can be significantly enlarged when MR-only simulation is considered

    The value of enhanced multiparameteric MRI diagnostic model for preoperatively predicting surgical methods of inferior vena cava in patients with renal tumors and inferior vena cava tumor thrombus

    No full text
    Abstract Background Inferior vena cava tumor thrombus (IVCTT) invading the IVC wall majorly affects the surgical method choice and prognosis in renal tumors. Enhanced multiparameteric MRI plays an important role in preoperative evaluation. In this work, an MRI-based diagnostic model for IVCTT was established so as to guide the preoperative decisions. Methods Preoperative MR images of 165 cases of renal tumors with IVCTT were retrospectively analyzed, and imaging indicators were analyzed, including IVCTT morphology and Mayo grade, IVCTT diameter measurements, bland thrombosis, primary MRI-based diagnosis of renal tumor, and involvement of contralateral renal vein. The indicators were analyzed based on intraoperative performance and resection scope of the IVC wall. Multivariate logistic regression analysis was used to establish the diagnostic model. Results The morphological classification of the IVCTT, primary MRI-based diagnosis of renal tumors, maximum transverse diameter of IVCTT, and length of the bland thrombus were the main indexes predicting IVC wall invasion. The MRI-based diagnostic model established according to these indexes had good diagnostic efficiency. The prediction probability of 0.61 was set as the cutoff value. The area under the curve of the test set was 0.88, sensitivity was 0.79, specificity was 0.85, and prediction accuracy was 0.79 under the optimal cutoff value. Conclusion The preoperative MRI-based diagnostic model could reliably predict IVC wall invasion, which is helpful for better prediction of IVC-associated surgical operations