71 research outputs found

    High spatial resolution myocardial perfusion cardiac magnetic resonance for the detection of coronary artery disease

    Get PDF
    Aims To evaluate the feasibility and diagnostic performance of high spatial resolution myocardial perfusion cardiac magnetic resonance (perfusion-CMR). Methods and results Fifty-four patients underwent adenosine stress perfusion-CMR. An in-plane spatial resolution of 1.4 × 1.4 mm2 was achieved by using 5× k-space and time sensitivity encoding (k-t SENSE). Perfusion was visually graded for 16 left ventricular and two right ventricular (RV) segments on a scale from 0 = normal to 3 = abnormal, yielding a perfusion score of 0-54. Diagnostic accuracy of the perfusion score to detect coronary artery stenosis of >50% on quantitative coronary angiography was determined. Sources and extent of image artefacts were documented. Two studies (4%) were non-diagnostic because of k-t SENSE-related and breathing artefacts. Endocardial dark rim artefacts if present were small (average width 1.6 mm). Analysis by receiver-operating characteristics yielded an area under the curve for detection of coronary stenosis of 0.85 [95% confidence interval (CI) 0.75-0.95] for all patients and 0.82 (95% CI 0.65-0.94) and 0.87 (95% CI 0.75-0.99) for patients with single and multi-vessel disease, respectively. Seventy-four of 102 (72%) RV segments could be analysed. Conclusion High spatial resolution perfusion-CMR is feasible in a clinical population, yields high accuracy to detect single and multi-vessel coronary artery disease, minimizes artefacts and may permit the assessment of RV perfusio

    Alive and kicking: suicide rates and major soccer events in Austria, Germany and Switzerland

    Get PDF
    BACKGROUND Major sporting events are postulated to reduce suicide rates by increased social connectedness, by identifying with winning teams, or, conversely, to increase suicide rates by the 'broken promise effect'. METHODS In our observational epidemiological study, we investigated changes in suicide rates between 1970 and 2017 in Austria, Germany and Switzerland during the European and World Soccer Championships in general, and on days that the home team played, won or lost. RESULTS Combining all three studied nations no statistically significant change in the incidence of daily suicides during soccer championships compared to a control period was noted (38.29 ± 9.02 vs. 37.33 ± 10.58; incidence risk ratio = 1.03; 95% confidence interval: 1.01-1.05, P = 0.05). Essentially, no differences in the expected directions were found, and none remained statistically significant after correcting for multiple comparisons in subgroups for country, age and gender in all three studied countries. Compared to a control period, neither a significant difference in the respective national suicide rate was found after Germany's four championship victories nor after Austria's emotional only win over Germany. CONCLUSION Our results do not support the assumption of increased social connectedness and, thus, lowered suicide risk during major sporting events or changes in suicide risk depending on the outcome of important games as predicted by the broken promise effect or changes in self-efficacy by identification with winning teams

    Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy

    Get PDF
    Aims To prospectively investigate the diagnostic accuracy of dual-source computed tomography coronary angiography (CTCA) to diagnose coronary stenoses in relation to body mass index (BMI), Agatston score (AS), and heart rate (HR) as compared with catheter coronary angiography (CCA). Methods and results Hundred and fifty consecutive patients (47 female, mean age 62.9 ± 12.1 years) underwent dual-source CTCA without HR control. Patients were divided into subgroups depending on the median of their BMI (26.0 kg/m2), AS (194), and HR (66 b.p.m.). CCA was considered the standard of reference. Mean BMI was 26.5 ± 4.2 kg/m2 (range 18.3-39.1 kg/m2), mean AS was 309 ± 408 (range 0-4387), and HR was 68.5 ± 12.6 b.p.m. (range 35-102 b.p.m.). Diagnostic image quality was found in 98.1% of all segments (2020/2059). Considering not-evaluative segments at CTCA as false-positive, overall per-patient sensitivity, specificity, positive, and negative predictive value were 96.6%, 86.8%, 82.6%, and 97.5%, respectively. High HR did not deteriorate diagnostic accuracy of CTCA. High BMI and AS were associated with a decrease in per-patient specificity to 84.1% and 77.8%, respectively, while sensitivity and negative predictive value remained high. Conclusion Dual-source CTCA provides high diagnostic accuracy irrespective of the HR and serves as a modality to rule-out coronary artery stenoses even in patients with high BMI and A

    TCT-4 Efficacy and Safety of Concurrent Administration of Clopidogrel-loading (600mg) and Prasugrel-loading (60mg) in Patients with Acute ST-Segment Elevation Myocardial Infarction

    Get PDF
    Background: Current STEMI guideline recommendations limit the use of prasugrel to clopidogrel-naïve patients. However, in daily clinical practice a considerable proportion of STEMI patients undergoing primary PCI are preloaded with clopidogrel. Whether the use of prasugrel in clopidogrel pretreated STEMI patients is safe remains unknown. Similarly, the efficacy of a combined loading dose regimen has not been evaluated. Methods: Between 1 September 2009 and 15 October 2012, a total of 1,157 STEMI patients were included in the randomized COMFORTABLE AMI trial (NCT 00962416) and 891 STEMI patients in the SPUM ACS registry (NCT 01000701) at 12 centers. Patients were divided into three groups according to type of peri-procedural antiplatelet loading: (1) Clopidogrel and subsequent Prasugrel loading dose [CP], (2) Prasugrel loading dose alone [P] (3) Clopidogrel loading dose alone [C]; 23 patients were excluded because they were not exposed to Clopidogrel and Prasugrel. The primary safety endpoint was the rate of BARC type 3, 4 and 5 bleeding at 30 days. The primary efficacy endpoint was the composite of cardiac death, nonfatal MI and nonfatal stroke at 30 days. Outcomes were analyzed using Cox's Regressions (crude) and multinomial ITPW weighted Cox's Regressions. Results: A total of 2,025 patients were analysed of whom 428 (21.1%) had received CP, 447 (22.1%) patients P alone, and 1,150 (56.8%) patients C alone. The primary safety endpoint was observed among 1.2% of CP, 1.6% of P, and 1.5% of C patients (CP vs C ad. HR 0.99 (0.36-2.72), PC vs P ad. HR 0.73 (0.22-2.41). The primary safety endpoint occurred less frequently among CP (1.9%) compared with C patients (5.0%, adjusted HR 0.47 (0.22-1.00), but with similar frequency among P and C patients (2.9% vs 5.0%, ad. HR 0.68 (0.27-1.73). The net clinical benefit outcome parameter tended to be lower among CP (2.8%) compared with C patients (6.3%, ad. HR 0.56 (0.30-1.05), whereas no significant difference was observed between P and C patients (3.8% vs 6.3%, ad. HR 0.85 (0.39-1.86). Conclusions: Among STEMI patients preloaded with Clopidogrel, the concurrent administration of a Prasugrel loading dose appears safe and potentially more effective than Clopiogrel alone

    Limits on different Majoron decay modes of 100^{100}Mo and 82^{82}Se for neutrinoless double beta decays in the NEMO-3 experiment

    Full text link
    The NEMO-3 tracking detector is located in the Fr\'ejus Underground Laboratory. It was designed to study double beta decay in a number of different isotopes. Presented here are the experimental half-life limits on the double beta decay process for the isotopes 100^{100}Mo and 82^{82}Se for different Majoron emission modes and limits on the effective neutrino-Majoron coupling constants. In particular, new limits on "ordinary" Majoron (spectral index 1) decay of 100^{100}Mo (T1/2>2.71022T_{1/2} > 2.7\cdot10^{22} y) and 82^{82}Se (T1/2>1.51022T_{1/2} > 1.5\cdot10^{22} y) have been obtained. Corresponding bounds on the Majoron-neutrino coupling constant are <(0.41.9)104 < (0.4-1.9) \cdot 10^{-4} and <(0.661.7)104< (0.66-1.7) \cdot 10^{-4}.Comment: 23 pages includind 4 figures, to be published in Nuclear Physics

    TORCETRAPIB INDUCES ENDOTHELIAL DYSFUNCTION IN SPONTANEOUSLY HYPERTENSIVE RATS

    Get PDF
    corecore