4 research outputs found

    Ultra-high system detection efficiency superconducting nanowire single-photon detectors for quantum photonics and life sciences

    No full text
    Ultra-high system detection efficiency (SDE) s uperconducting nanowire single-photon detectors are demonstrated for a broad range of wavelengths, from UV to mid-infrared, opening novel possibilities in the fields of quantum photonics, neuroimaging and astronomy.Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.ImPhys/OpticsQN/Groeblacher LabQN/Quantum Nanoscienc

    Efficient mid-infrared single-photon detection using superconducting NbTiN nanowires with high time resolution in a Gifford-McMahon cryocooler

    No full text
    Shortly after their inception, superconducting nanowire single-photon detectors (SNSPDs) became the leading quantum light detection technology. With the capability of detecting single-photons with near-unity efficiency, high time resolution, low dark count rate, and fast recovery time, SNSPDs outperform conventional single-photon detection techniques. However, detecting lower energy single photons (<0.8 eV) with high efficiency and low timing jitter has remained a challenge. To achieve unity internal efficiency at mid-infrared wavelengths, previous works used amorphous superconducting materials with low energy gaps at the expense of reduced time resolution (close to a nanosecond), and by operating them in complex milliKelvin (mK) dilution refrigerators. In this work, we provide an alternative approach with SNSPDs fabricated from 5 to 9.5 nm thick NbTiN superconducting films and devices operated in conventional Gifford-McMahon cryocoolers. By optimizing the superconducting film deposition process, film thickness, and nanowire design, our fiber-coupled devices achieved >70% system detection efficiency (SDE) at 2 μm and sub-15 ps timing jitter. Furthermore, detectors from the same batch demonstrated unity internal detection efficiency at 3 μm and 80% internal efficiency at 4 μm, paving the road for an efficient mid-infrared single-photon detection technology with unparalleled time resolution and without mK cooling requirements. We also systematically studied the dark count rates (DCRs) of our detectors coupled to different types of mid-infrared optical fibers and blackbody radiation filters. This offers insight into the trade-off between bandwidth and DCRs for mid-infrared SNSPDs. To conclude, this paper significantly extends the working wavelength range for SNSPDs made from polycrystalline NbTiN to 1.5-4 μm, and we expect quantum optics experiments and applications in the mid-infrared range to benefit from this far-reaching technology.QN/Groeblacher LabImPhys/Optic

    In vivo non-invasive confocal fluorescence imaging beyond 1,700 nm using superconducting nanowire single-photon detectors

    No full text
    Light scattering by biological tissues sets a limit to the penetration depth of high-resolution optical microscopy imaging of live mammals in vivo. An effective approach to reduce light scattering and increase imaging depth is to extend the excitation and emission wavelengths to the second near-infrared window (NIR-II) at >1,000 nm, also called the short-wavelength infrared window. Here we show biocompatible core–shell lead sulfide/cadmium sulfide quantum dots emitting at ~1,880 nm and superconducting nanowire single-photon detectors for single-photon detection up to 2,000 nm, enabling a one-photon excitation fluorescence imaging window in the 1,700–2,000 nm (NIR-IIc) range with 1,650 nm excitation—the longest one-photon excitation and emission for in vivo mouse imaging so far. Confocal fluorescence imaging in NIR-IIc reached an imaging depth of ~1,100 μm through an intact mouse head, and enabled non-invasive cellular-resolution imaging in the inguinal lymph nodes of mice without any surgery. We achieve in vivo molecular imaging of high endothelial venules with diameters as small as ~6.6 μm, as well as CD169 + macrophages and CD3 + T cells in the lymph nodes, opening the possibility of non-invasive intravital imaging of immune trafficking in lymph nodes at the single-cell/vessel-level longitudinally.Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.ImPhys/Optic

    Multimode-fiber-coupled superconducting nanowire single-photon detectors with high detection efficiency and time resolution

    No full text
    In the past decade, superconducting nanowire single-photon detectors (SNSPDs) have gradually become an indispensable part of any demanding quantum optics experiment. Until now, most SNSPDs have been coupled to single-mode fibers. SNSPDs coupled to multimode fibers have shown promising efficiencies but have yet to achieve high time resolution. For a number of applications ranging from quantum nano-photonics to bio-optics, high efficiency and high time resolution are desired at the same time. In this paper, we demonstrate the role of polarization on the efficiency of multimode-fiber-coupled detectors and fabricated high-performance 20 µm, 25 µm, and 50 µm diameter detectors targeted for visible, near-infrared, and telecom wavelengths. A custom-built setup was used to simulate realistic experiments with randomized modes in the fiber. We achieved over 80% system efficiency and <20 ps timing jitter for 20 µm SNSPDs. Also, we realized 70% system efficiency and <20 ps timing jitter for 50 µm SNSPDs. The high-efficiency multimode-fiber-coupled SNSPDs with unparalleled time resolution will benefit various quantum optics experiments and applications in the future.ImPhys/Optic
    corecore