47,671 research outputs found

    Compact modes in quasi one dimensional coupled magnetic oscillators

    Full text link
    In this work we study analytically and numerically the spectrum and localization properties of three quasi-one-dimensional (ribbons) split-ring resonator arrays which possess magnetic flatbands, namely, the stub, Lieb and kagome lattices, and how their spectra is affected by the presence of perturbations that break the delicate geometrical interference needed for a magnetic flatband to exist. We find that the Stub and Lieb ribbons are stable against the three types of perturbations considered here, while the kagome ribbon is, in general, unstable. When losses are incorporated, all flatbands remain dispersionless but become complex, with the kagome ribbon exhibiting the highest loss rate.Comment: 11 pages, 15 figure

    Quasinormal frequencies of asymptotically flat two-dimensional black holes

    Full text link
    We discuss whether the minimally coupled massless Klein-Gordon and Dirac fields have well defined quasinormal modes in single horizon, asymptotically flat two-dimensional black holes. To get the result we solve the equations of motion in the massless limit and we also calculate the effective potentials of Schrodinger type equations. Furthermore we calculate exactly the quasinormal frequencies of the Dirac field propagating in the two-dimensional uncharged Witten black hole. We compare our results on its quasinormal frequencies with other already published.Comment: 12 pages. Accepted for publication in Gen. Rel. and Gra

    Zeeman-type dragging in the Kerr--Newman and NUT spacetimes

    Full text link
    In this communication we discuss two distinct Zeeman-type gravitomagnetic effects deserving attention since they can be easily characterized in their exact form, not via approximation procedures. Some observations are also made on gravitoelectric effects.Comment: 5 pages, a talk delivered at the 11th Marcel Grossmann Meeting (2006

    Heart Rate Extraction from Novel Neck Photoplethysmography Signals.

    Get PDF
    This paper demonstrates for the first time how heart rate (HR) can be extracted from novel neck photoplethysmography (PPG). A novel algorithm is presented, which when tested in neck PPG signals recorded from 9 subjects at different respiratory rates, obtained good precision with respect to gold standard ECG signals. Mean absolute error (MAE), standard deviation error (SDAE) and root-mean-square error (RMSE) resulted in 1.22, 1.54 and 1.98 beats per minute (BPM), respectively. HRneck estimation showed strong correlation (R=0.94) with reference HRECG. Good agreement between both techniques was also demonstrated by Bland-Altman analysis. The bias between mean HR paired differences was -0.16 BPM and 95% limits of agreement (LoA) were (-4.7, 4.4). Comparatively, for widely used finger PPG, errors were slightly smaller (MAE=0.38 BPM, SDAE=0.48 BPM, RMSE=0.62BPM) and the correlation with reference ECG was also very close to 1 (R=0.99). Bias of -0.04 BPM and 95% LoA (-1.5, 1.4), also showed high degree of agreement. However, these findings show the potential the neck could have as an alternative body location for wearable monitors, aiming to reduce the number of sensing sites whilst still providing access to a wide variety of physiological parameters

    Reset and switch protocols at Landauer limit in a graphene buckled ribbon

    Full text link
    Heat produced during a reset operation is meant to show a fundamental bound known as Landauer limit, while simple switch operations have an expected minimum amount of produced heat equal to zero. However, in both cases, present-day technology realizations dissipate far beyond these theoretical limits. In this paper we present a study based on molecular dynamics simulations, where reset and switch protocols are applied on a graphene buckled ribbon, employed here as a nano electromechanical switch working at the thermodynamic limit
    corecore