63 research outputs found

    Aneurysm Coil Embolization Using a 1.5-Fr Distal Outer Diameter Microcatheter

    Get PDF
    The current assortment of microcatheters widely used for aneurysm coil embolization may not be well suited for several anatomic variants, including excessive vascular tortuosity and small aneurysms less than 3 mm. Longer microcatheters designed with a smaller caliber that can accommodate and deliver coils may be of use in these situations. This case series and literature review illustrates the advantages and limitations of the Marathon microcatheter (Covidien, Irvine, CA, USA) when used for coil embolization of cerebral aneurysms. Despite some technical compromises including the distal marker, length, and the risk of buckling, the Marathon microcatheter was able to adequately deliver coils to achieve satisfactory occlusion of cerebral aneurysms. We found unique advantages with regards to length and smaller distal outer diameter (OD). These results may serve as a guide for the further development of a microcatheter used for coil embolization that has the features of a smaller distal OD and longer length

    First Human Evaluation of Endothelial Healing after a Pipeline Flex Embolization Device with Shield Technology Implanted in Posterior Circulation Using Optical Coherence Tomography

    Get PDF
    A 64-year-old female presented with an incidentally-discovered right posterior inferior cerebral artery (PICA) aneurysm, initially treated in 2015 by simple coiling. Follow-up demonstrated significant coil compaction that required retreatment. Retreatment was done uneventfully using a Pipeline embolization device (PED) shield deployed starting from the basilar artery and ending at the V4 segment of the vertebral artery. Eight-weeks post-deployment, a follow-up digital subtraction imaging (DSA) and intravascular imaging with optical coherence tomography were obtained. The intravascular imaging demonstrated that the flow diverter had good wall apposition and concentric neointimal growth over the braid with exception to the areas that the PED was not in contact with the endothelial wall, such as at the right PICA ostium and at the vertebrobasilar junction. The entire procedure was safe, and the patient had no complications. In this article, we describe for the first time the assessment of the status of endothelial “healing” of the PED shield at 8-weeks

    A neurovascular high-frequency optical coherence tomography system enables in situ cerebrovascular volumetric microscopy

    Get PDF
    Intravascular imaging has emerged as a valuable tool for the treatment of coronary and peripheral artery disease; however, no solution is available for safe and reliable use in the tortuous vascular anatomy of the brain. Endovascular treatment of stroke is delivered under image guidance with insufficient resolution to adequately assess underlying arterial pathology and therapeutic devices. High-resolution imaging, enabling surgeons to visualize cerebral arteries\u27 microstructure and micron-level features of neurovascular devices, would have a profound impact in the research, diagnosis, and treatment of cerebrovascular diseases. Here, we present a neurovascular high-frequency optical coherence tomography (HF-OCT) system, including an imaging console and an endoscopic probe designed to rapidly acquire volumetric microscopy data at a resolution approaching 10 microns in tortuous cerebrovascular anatomies. Using a combination of in vitro, ex vivo, and in vivo models, the feasibility of HF-OCT for cerebrovascular imaging was demonstrated

    Mobile Real-time Tracking of Acute Stroke Patients and Instant, Secure Inter-team Communication - the Join App

    Get PDF
    PurposeThe primary correlate to survival and preservation of neurologic function in patients suffering from an acute ischemic stroke is time from symptom onset to initiation of therapy and reperfusion. Communication and coordination among members of the stroke team are essential to maximizing efficiency and subsequently early reperfusion. In this work, we aim to describe our preliminary experience using the Join mobile application as a means to improve interdisciplinary team communication and efficiency.Materials and MethodsWe describe our pilot experience with the initiation of the Join mobile application between July 2015 and July 2016. With this application, a mobile beacon is transported with the patient on the ambulance. Transportation milestone timestamps and geographic coordinates are transmitted to the treating facility and instantly communicated to all treatment team members. The transport team / patient can be tracked en route to the treating facility.ResultsDuring our pilot study, 62 patients were triaged and managed using the Join application. Automated time-stamping of critical events, geographic tracking of patient transport and summary documents were obtained for all patients. Treatment team members had an overall favorable impression of the Join application and recommended its continued use.ConclusionThe Join application is one of several components of a multi-institutional, interdisciplinary effort to improve the treatment of patients with acute ischemic stroke. The ability of the treatment team to track patient transport and communicate with the transporting team may improve reperfusion time and, therefore, improve neurologic outcomes

    Glucose modifies the effect of endovascular thrombectomy in patients with acute stroke: a pooled-data meta-analysis

    Get PDF
    Background and Purpose: Hyperglycemia is a negative prognostic factor following acute ischemic stroke but is not known whether glucose is associated with the effects of endovascular thrombectomy in patients with large vessel stroke. In a pooled-data meta-analysis, we analyzed whether serum glucose is a treatment modifier of the efficacy of endovascular thrombectomy in acute stroke. Methods: Seven randomized trials compared endovascular thrombectomy with standard care between 2010 and 2017 (HERMES Collaboration). 1764 patients with large vessel stroke were allocated to endovascular thrombectomy (n=871) or standard care (n=893). Measurements included blood glucose on admission and functional outcome [modified Rankin Scale (mRS) range: 0-6; lower scores indicating less disability] at 3 months. The primary analysis evaluated whether glucose modified the effect of EVT over standard care on functional outcome, using ordinal logistic regression to test the interaction between treatment and glucose level. Results: Median (IQR) serum glucose on admission was 120 (104-140) mg/dl [6.6mmol/l (5.7-7.7) mmol/l]. Endovascular thrombectomy (EVT) was better than standard care in the overall pooled-data analysis [common odds ratio (acOR), 2.00 (95% CI 1.69–2.38); however, lower glucose levels were associated with greater effects of EVT over standard care. The interaction was nonlinear such that significant interactions were found in subgroups of patients split at glucose < or > 90mg/dl (5.0mmol/l) [(p=0.019 for interaction, acOR 3.81 (95% CI 1.73–8.41) for patients < 90 mg/dl vs 1.83 (95% CI 1.53–2.19) for patients > 90 mg/dl], and glucose < or > 100mg/dl (5.5mmol/l) [(p=0.004 for interaction, acOR 3.17 (95% CI 2.04–4.93) vs acOR 1.72 (95% CI 1.42–2.08)], but not between subgroups above these levels of glucose. Conclusions: Endovascular thrombectomy improved stroke outcomes compared to standard treatment regardless of glucose levels but the treatment effects were larger at lower glucose levels, with significant interaction effects persisting up to 90 to 100mg/dl (5.0-5.5mmol/l). Whether tight control of glucose improves the efficacy of endovascular thrombectomy following large vessel stroke warrants appropriate testing

    Imaging features and safety and efficacy of endovascular stroke treatment: a meta-analysis of individual patient-level data

    Get PDF
    Background: Evidence regarding whether imaging can be used effectively to select patients for endovascular thrombectomy (EVT) is scarce. We aimed to investigate the association between baseline imaging features and safety and efficacy of EVT in acute ischaemic stroke caused by anterior large-vessel occlusion. Methods: In this meta-analysis of individual patient-level data, the HERMES collaboration identified in PubMed seven randomised trials in endovascular stroke that compared EVT with standard medical therapy, published between Jan 1, 2010, and Oct 31, 2017. Only trials that required vessel imaging to identify patients with proximal anterior circulation ischaemic stroke and that used predominantly stent retrievers or second-generation neurothrombectomy devices in the EVT group were included. Risk of bias was assessed with the Cochrane handbook methodology. Central investigators, masked to clinical information other than stroke side, categorised baseline imaging features of ischaemic change with the Alberta Stroke Program Early CT Score (ASPECTS) or according to involvement of more than 33% of middle cerebral artery territory, and by thrombus volume, hyperdensity, and collateral status. The primary endpoint was neurological functional disability scored on the modified Rankin Scale (mRS) score at 90 days after randomisation. Safety outcomes included symptomatic intracranial haemorrhage, parenchymal haematoma type 2 within 5 days of randomisation, and mortality within 90 days. For the primary analysis, we used mixed-methods ordinal logistic regression adjusted for age, sex, National Institutes of Health Stroke Scale score at admission, intravenous alteplase, and time from onset to randomisation, and we used interaction terms to test whether imaging categorisation at baseline modifies the association between treatment and outcome. This meta-analysis was prospectively designed by the HERMES executive committee but has not been registered. Findings: Among 1764 pooled patients, 871 were allocated to the EVT group and 893 to the control group. Risk of bias was low except in the THRACE study, which used unblinded assessment of outcomes 90 days after randomisation and MRI predominantly as the primary baseline imaging tool. The overall treatment effect favoured EVT (adjusted common odds ratio [cOR] for a shift towards better outcome on the mRS 2·00, 95% CI 1·69–2·38; p<0·0001). EVT achieved better outcomes at 90 days than standard medical therapy alone across a broad range of baseline imaging categories. Mortality at 90 days (14·7% vs 17·3%, p=0·15), symptomatic intracranial haemorrhage (3·8% vs 3·5%, p=0·90), and parenchymal haematoma type 2 (5·6% vs 4·8%, p=0·52) did not differ between the EVT and control groups. No treatment effect modification by baseline imaging features was noted for mortality at 90 days and parenchymal haematoma type 2. Among patients with ASPECTS 0–4, symptomatic intracranial haemorrhage was seen in ten (19%) of 52 patients in the EVT group versus three (5%) of 66 patients in the control group (adjusted cOR 3·94, 95% CI 0·94–16·49; pinteraction=0·025), and among patients with more than 33% involvement of middle cerebral artery territory, symptomatic intracranial haemorrhage was observed in 15 (14%) of 108 patients in the EVT group versus four (4%) of 113 patients in the control group (4·17, 1·30–13·44, pinteraction=0·012). Interpretation: EVT achieves better outcomes at 90 days than standard medical therapy across a broad range of baseline imaging categories, including infarcts affecting more than 33% of middle cerebral artery territory or ASPECTS less than 6, although in these patients the risk of symptomatic intracranial haemorrhage was higher in the EVT group than the control group. This analysis provides preliminary evidence for potential use of EVT in patients with large infarcts at baseline. Funding: Medtronic

    Neuro-endovascular Embolic Agent for Treatment of a Renal Arteriovenous Fistula

    No full text
    Renal arteriovenous fistula is a known complication following a renal biopsy, and may require catheter based embolization. Distal location of these fistulas in the renal parenchyma in many a case may necessitate non-traditional embolic materials. Liquid embolic agents that allow a controlled delivery may be suitable in this situation, as demonstrated in this case report

    Transvenous arteriovenous malformation embolization

    No full text
    Transvenous embolization of arteriovenous malformations has emerged as a safe and effective intervention. In carefully selected patients the transvenous approach has shown efficacy similar to that of conventional transarterial routes. The optimal lesions amenable to the transvenous approach have not been robustly delineated; however, the approach is reserved for small, deep seeded, single venous drainage lesions with poorly amenable arterial vascular supply. In this video we demonstrate a case of transvernous Onyx embolization of a Spetzler-Martin grade 3 (SM3) left hemispheric, ruptured arteriovenous malformation. The patient underwent successful, single session, complete embolization of the arteriovenous malformation through a venous route without further complications or repeat treatment
    • …
    corecore