77 research outputs found

    A usability study of two knowledge acquisition tools

    Get PDF
    In today's world, knowledge-based systems are widely used for both large and small tasks. Acquiring knowledge from domain experts is one of the major bottlenecks in building such systems, and hence, Knowledge Acquisition (KA) tools are given importance. The goal of these tools was to assist the knowledge engineer in eliciting knowledge from domain experts. Until recently, the usage of these tools was limited to people with significant computer expertise. User interface difficulties form one source that prevents people at large from receiving the expected benefits of KA tools. This has prompted the investigation of the usability of two popular knowledge acquisition tools in this thesis. This thesis focuses on designing and conducting a usability test with two popular KA tools: ProteĢgeĢ2000 and PCPACK4. The purpose of this study is to assess the usability of these two KA tools against a set of criteria, and to provide recommendations for further improvement of these tools or to help in the development of new KA tools. To conduct this usability test, this thesis adopted and modified Hix's methodology for the evaluation of knowledge-acquisition tools. Testing with a small set of end-users revealed several usability issues. Based on these observations recommendations are made in this thesis for further enhancement of usage of KA tool

    Do LGBT Workplace Diversity Policies Create Value for Firms?

    Get PDF
    We show that the U.S. anti-discriminatory laws prohibiting discrimination in the workplace based on sexual orientation and gender identity (i.e. lesbian, gay, bisexual, and transgender (LGBT) identities) spur innovation, which ultimately leads to higher firm performance. We use the Human Rights Campaignā€™s Corporate Equality Index (CEI) of 398 (1592 firm-year observations) U.S. firms between 2011 and 2014, and find a significantly positive relationship between CEI and firm innovation. We also find that an interacting effect of CEI and firm innovation leads to higher firm performance. We use our understanding of Rawlsā€™ Theory of Justice and stakeholder theory to show that firms with workplace diversity policies are likely to be more innovative and perform better than those without such policies. Our results are robust to endogeneity, reverse causality and simultaneity issues. Our results will trigger debate in similar markets around the globe on the economic benefits of LGBT workplace diversity policies for firms

    Tetraplex PCR assay involving double gene-sites discriminates beef and buffalo in Malaysian meat curry and burger products

    Get PDF
    Replacement of beef by buffalo and vice versa is frequent in global markets, but their authentication is challenging in processed foods due to the fragmentation of most biomarkers including DNA. The shortening of target sequences through use of two target sites might ameliorate assay reliability because it is highly unlikely that both targets will be lost during food processing. For the first time, we report a tetraplex polymerase chain reaction (PCR) assay targeting two different DNA regions in beef (106 and 120-bp) and buffalo (90 and 138-bp) mitochondrial genes to discriminate beef and buffalo in processed foods. All targets were stable under boiling, autoclaving and microwave cooking conditions. A survey in Malaysian markets revealed 71% beef curries contained buffalo but there was no buffalo in beef burgers. The assay detected down to 0.01 ng DNA and 1% meat in admixed and burger products

    Arsenic exposure is associated with pediatric pneumonia in rural Bangladesh: a case control study

    Get PDF
    Background: Pneumonia is the leading cause of death for children under 5 years of age globally, making research on modifiable risk factors for childhood pneumonia important for reducing this disease burden. Millions of children globally are exposed to elevated levels of arsenic in drinking water. However, there is limited data on the association between arsenic exposure and respiratory infections, particularly among pediatric populations. Methods: This case control study of 153 pneumonia cases and 296 controls 28 days to 59 months of age in rural Bangladesh is the first to assess whether arsenic exposure is a risk factor for pneumonia in a pediatric population. Cases had physician diagnosed World Health Organization defined severe or very severe pneumonia. Urine collected during hospitalization (hospital admission time point) and 30 days later (convalescent time point) from cases and a single specimen from community controls was tested for urinary arsenic by graphite furnace atomic absorption. Results: The odds for pneumonia was nearly double for children with urinary arsenic concentrations higher than the first quartile (ā‰„6 Ī¼g/L) at the hospital admission time point (Odd Ratio (OR):1.88 (95 % Confidence Interval (CI): 1.01, 3.53)), after adjustment for urinary creatinine, weight for height, breastfeeding, paternal education, age, and number of people in the household. This was consistent with findings at the convalescent time point where the adjusted OR for children with urinary arsenic concentrations greater than the first quartile (ā‰„6 Ī¼g/L) was 2.32 (95 % CI: 1.33, 4.02). Conclusion: We observed a nearly two times higher odds of pneumonia for children with creatinine adjusted urinary arsenic concentrations greater than the first quartile (ā‰„6 Ī¼g/L) at the hospital admission time point. This novel finding suggests that low to moderate arsenic exposure may be a risk factor for pneumonia in children under 5 years of age

    Safety of Induced Sputum Collection in Children Hospitalized With Severe or Very Severe Pneumonia.

    Get PDF
    BACKGROUND.: Induced sputum (IS) may provide diagnostic information about the etiology of pneumonia. The safety of this procedure across a heterogeneous population with severe pneumonia in low- and middle-income countries has not been described. METHODS.: IS specimens were obtained as part a 7-country study of the etiology of severe and very severe pneumonia in hospitalized children <5 years of age. Rigorous clinical monitoring was done before, during, and after the procedure to record oxygen requirement, oxygen saturation, respiratory rate, consciousness level, and other evidence of clinical deterioration. Criteria for IS contraindications were predefined and serious adverse events (SAEs) were reported to ethics committees and a central safety monitor. RESULTS.: A total of 4653 IS procedures were done among 3802 children. Thirteen SAEs were reported in relation to collection of IS, or 0.34% of children with at least 1 IS specimen collected (95% confidence interval, 0.15%-0.53%). A drop in oxygen saturation that required supplemental oxygen was the most common SAE. One child died after feeding was reinitiated 2 hours after undergoing sputum induction; this death was categorized as "possibly related" to the procedure. CONCLUSIONS.: The overall frequency of SAEs was very low, and the nature of most SAEs was manageable, demonstrating a low-risk safety profile for IS collection even among severely ill children in low-income-country settings. Healthcare providers should monitor oxygen saturation and requirements during and after IS collection, and assess patients prior to reinitiating feeding after the IS procedure, to ensure patient safety

    Microscopic Analysis and Quality Assessment of Induced Sputum From Children With Pneumonia in the PERCH Study.

    Get PDF
    BACKGROUND.: It is standard practice for laboratories to assess the cellular quality of expectorated sputum specimens to check that they originated from the lower respiratory tract. The presence of low numbers of squamous epithelial cells (SECs) and high numbers of polymorphonuclear (PMN) cells are regarded as indicative of a lower respiratory tract specimen. However, these quality ratings have never been evaluated for induced sputum specimens from children with suspected pneumonia. METHODS.: We evaluated induced sputum Gram stain smears and cultures from hospitalized children aged 1-59 months enrolled in a large study of community-acquired pneumonia. We hypothesized that a specimen representative of the lower respiratory tract will contain smaller quantities of oropharyngeal flora and be more likely to have a predominance of potential pathogens compared to a specimen containing mainly saliva. The prevalence of potential pathogens cultured from induced sputum specimens and quantity of oropharyngeal flora were compared for different quantities of SECs and PMNs. RESULTS.: Of 3772 induced sputum specimens, 2608 (69%) had 25 PMNs per LPF, measures traditionally associated with specimens from the lower respiratory tract in adults. Using isolation of low quantities of oropharyngeal flora and higher prevalence of potential pathogens as markers of higher quality, 25 PMNs per LPF) was the microscopic variable most associated with high quality of induced sputum. CONCLUSIONS.: Quantity of SECs may be a useful quality measure of induced sputum from young children with pneumonia

    Limited Utility of Polymerase Chain Reaction in Induced Sputum Specimens for Determining the Causes of Childhood Pneumonia in Resource-Poor Settings: Findings From the Pneumonia Etiology Research for Child Health (PERCH) Study.

    Get PDF
    BACKGROUND.: Sputum examination can be useful in diagnosing the cause of pneumonia in adults but is less well established in children. We sought to assess the diagnostic utility of polymerase chain reaction (PCR) for detection of respiratory viruses and bacteria in induced sputum (IS) specimens from children hospitalized with severe or very severe pneumonia. METHODS.: Among children aged 1-59 months, we compared organism detection by multiplex PCR in IS and nasopharyngeal/oropharyngeal (NP/OP) specimens. To assess whether organism presence or density in IS specimens was associated with chest radiographic evidence of pneumonia (radiographic pneumonia), we compared prevalence and density in IS specimens from children with radiographic pneumonia and children with suspected pneumonia but without chest radiographic changes or clinical or laboratory findings suggestive of pneumonia (nonpneumonia group). RESULTS.: Among 4232 cases with World Health Organization-defined severe or very severe pneumonia, we identified 1935 (45.7%) with radiographic pneumonia and 573 (13.5%) with nonpneumonia. The organism detection yield was marginally improved with IS specimens (96.2% vs 92.4% for NP/OP specimens for all viruses combined [P = .41]; 96.9% vs 93.3% for all bacteria combined [P = .01]). After accounting for presence in NP/OP specimens, no organism was detected more frequently in the IS specimens from the radiographic pneumonia compared with the nonpneumonia cases. Among high-quality IS specimens, there were no statistically significant differences in organism density, except with cytomegalovirus, for which there was a higher quantity in the IS specimens from cases with radiographic pneumonia compared with the nonpneumonia cases (median cycle threshold value, 27.9 vs 28.5, respectively; P = .01). CONCLUSIONS.: Using advanced molecular methods with IS specimens provided little additional diagnostic information beyond that obtained with NP/OP swab specimens

    Pertussis-Associated Pneumonia in Infants and Children From Low- and Middle-Income Countries Participating in the PERCH Study.

    Get PDF
    BACKGROUND: ā€ƒFew data exist describing pertussis epidemiology among infants and children in low- and middle-income countries to guide preventive strategies. METHODS: ā€ƒChildren 1-59 months of age hospitalized with World Health Organization-defined severe or very severe pneumonia in 7 African and Asian countries and similarly aged community controls were enrolled in the Pneumonia Etiology Research for Child Health study. They underwent a standardized clinical evaluation and provided nasopharyngeal and oropharyngeal swabs and induced sputum (cases only) for Bordetella pertussis polymerase chain reaction. Risk factors and pertussis-associated clinical findings were identified. RESULTS: ā€ƒBordetella pertussis was detected in 53 of 4200 (1.3%) cases and 11 of 5196 (0.2%) controls. In the age stratum 1-5 months, 40 (2.3% of 1721) cases were positive, all from African sites, as were 8 (0.5% of 1617) controls. Pertussis-positive African cases 1-5 months old, compared to controls, were more often human immunodeficiency virus (HIV) uninfected-exposed (adjusted odds ratio [aOR], 2.2), unvaccinated (aOR, 3.7), underweight (aOR, 6.3), and too young to be immunized (aOR, 16.1) (all P ā‰¤ .05). Compared with pertussis-negative African cases in this age group, pertussis-positive cases were younger, more likely to vomit (aOR, 2.6), to cough ā‰„14 days (aOR, 6.3), to have leukocyte counts >20 000 cells/ĀµL (aOR, 4.6), and to have lymphocyte counts >10 000 cells/ĀµL (aOR, 7.2) (all P ā‰¤ .05). The case fatality ratio of pertussis-infected pneumonia cases 1-5 months of age was 12.5% (95% confidence interval, 4.2%-26.8%; 5/40); pertussis was identified in 3.7% of 137 in-hospital deaths among African cases in this age group. CONCLUSIONS: ā€ƒIn the postneonatal period, pertussis causes a small fraction of hospitalized pneumonia cases and deaths; however, case fatality is substantial. The propensity to infect unvaccinated infants and those at risk for insufficient immunity (too young to be vaccinated, premature, HIV-infected/exposed) suggests that the role for maternal vaccination should be considered along with efforts to reduce exposure to risk factors and to optimize childhood pertussis vaccination coverage

    Colonization Density of the Upper Respiratory Tract as a Predictor of Pneumonia-Haemophilus influenzae, Moraxella catarrhalis, Staphylococcus aureus, and Pneumocystis jirovecii.

    Get PDF
    BACKGROUND.: There is limited information on the association between colonization density of upper respiratory tract colonizers and pathogen-specific pneumonia. We assessed this association for Haemophilus influenzae, Moraxella catarrhalis, Staphylococcus aureus, and Pneumocystis jirovecii. METHODS.: In 7 low- and middle-income countries, nasopharyngeal/oropharyngeal swabs from children with severe pneumonia and age-frequency matched community controls were tested using quantitative polymerase chain reaction (PCR). Differences in median colonization density were evaluated using the Wilcoxon rank-sum test. Density cutoffs were determined using receiver operating characteristic curves. Cases with a pathogen identified from lung aspirate culture or PCR, pleural fluid culture or PCR, blood culture, and immunofluorescence for P. jirovecii defined microbiologically confirmed cases for the given pathogens. RESULTS.: Higher densities of H. influenzae were observed in both microbiologically confirmed cases and chest radiograph (CXR)-positive cases compared to controls. Staphylococcus aureus and P. jirovecii had higher densities in CXR-positive cases vs controls. A 5.9 log10 copies/mL density cutoff for H. influenzae yielded 86% sensitivity and 77% specificity for detecting microbiologically confirmed cases; however, densities overlapped between cases and controls and positive predictive values were poor (<3%). Informative density cutoffs were not found for S. aureus and M. catarrhalis, and a lack of confirmed case data limited the cutoff identification for P. jirovecii. CONCLUSIONS.: There is evidence for an association between H. influenzae colonization density and H. influenzae-confirmed pneumonia in children; the association may be particularly informative in epidemiologic studies. Colonization densities of M. catarrhalis, S. aureus, and P. jirovecii are unlikely to be of diagnostic value in clinical settings

    Digitally recorded and remotely classified lung auscultation compared with conventional stethoscope classifications among children aged 1-59 months enrolled in the Pneumonia Etiology Research for Child Health (PERCH) case-control study.

    Get PDF
    BACKGROUND: Diagnosis of pneumonia remains challenging. Digitally recorded and remote human classified lung sounds may offer benefits beyond conventional auscultation, but it is unclear whether classifications differ between the two approaches. We evaluated concordance between digital and conventional auscultation. METHODS: We collected digitally recorded lung sounds, conventional auscultation classifications and clinical measures and samples from children with pneumonia (cases) in low-income and middle-income countries. Physicians remotely classified recordings as crackles, wheeze or uninterpretable. Conventional and digital auscultation concordance was evaluated among 383 pneumonia cases with concurrently (within 2 hours) collected conventional and digital auscultation classifications using prevalence-adjusted bias-adjusted kappa (PABAK). Using an expanded set of 737 cases that also incorporated the non-concurrently collected assessments, we evaluated whether associations between auscultation classifications and clinical or aetiological findings differed between conventional or digital auscultation using Ļ‡2 tests and logistic regression adjusted for age, sex and site. RESULTS: Conventional and digital auscultation concordance was moderate for classifying crackles and/or wheeze versus neither crackles nor wheeze (PABAK=0.50), and fair for crackles-only versus not crackles-only (PABAK=0.30) and any wheeze versus no wheeze (PABAK=0.27). Crackles were more common on conventional auscultation, whereas wheeze was more frequent on digital auscultation. Compared with neither crackles nor wheeze, crackles-only on both conventional and digital auscultation was associated with abnormal chest radiographs (adjusted OR (aOR)=1.53, 95% CI 0.99 to 2.36; aOR=2.09, 95% CI 1.19 to 3.68, respectively); any wheeze was inversely associated with C-reactive protein >40 mg/L using conventional auscultation (aOR=0.50, 95% CI 0.27 to 0.92) and with very severe pneumonia using digital auscultation (aOR=0.67, 95% CI 0.46 to 0.97). Crackles-only on digital auscultation was associated with mortality compared with any wheeze (aOR=2.70, 95% CI 1.12 to 6.25). CONCLUSIONS: Conventional auscultation and remotely-classified digital auscultation displayed moderate concordance for presence/absence of wheeze and crackles among cases. Conventional and digital auscultation may provide different classification patterns, but wheeze was associated with decreased clinical severity on both
    • ā€¦
    corecore