323 research outputs found

    AGATA: Performance of γ\gamma-ray tracking and associated algorithms

    Full text link
    AGATA is a modern γ\gamma-ray spectrometer for in-beam nuclear structure studies, based on γ\gamma-ray tracking. Since more than a decade, it has been operated performing experimental physics campaigns in different international laboratories (LNL, GSI, GANIL). This paper reviews the obtained results concerning the performances of γ\gamma-ray tracking in AGATA and associated algorithms. We discuss γ\gamma-ray tracking and algorithms developed for AGATA. Then, we present performance results in terms of efficiency and peak-to-total for AGATA. The importance of the high effective angular resolution of γ\gamma-ray tracking arrays is emphasised, e.g. with respect to Doppler correction. Finally, we briefly touch upon the subject of γ\gamma-ray imaging and its connection to γ\gamma-ray tracking

    Impact of blood tube additives and timing of sampling on blood taurine concentrations in clinically healthy dogs

    Get PDF
    Introduction: Dilated cardiomyopathy can be associated with taurine deficiency in dogs. Blood taurine concentrations can be analyzed in whole blood (WB) and plasma. The study objectives were to investigate agreement between taurine concentrations measured in WB, heparin plasma, and EDTA plasma, deter-mine intraindividual variation in healthy dogs, and evaluate if time from feeding to sampling impacts concentrations. Animals: 10 English Cocker spaniels and 10 dogs of various breeds. Materials and methods: Dogs were fasted 12 h prior to initial blood sampling, and the blood was collected at five occasions over 8 h. Food was offered immediately after first and 1 h after fourth sampling time point. Results: Agreement between taurine concentrations in EDTA plasma and hepari-nized plasma was good (mean difference 4.5 nmol/mL, 95% confidence interval (CI) 36.8-45.8 nmol/mL). WB concentrations were systematically higher than EDTA and heparin plasma concentrations (mean difference 132.7 nmol/mL, 95% CI 23.6-241.8 nmol/mL, and 127.6 nmol/mL, 95% CI 28.6-226.6 nmol/mL, respectively, all P < 0.001). Intraindividual daily variations in taurine concentration were seen in all additives, with largest variations in plasma (P < 0.001). Taurine concentration in heparinized plasma was higher at first and fifth sampling time points compared to the fourth (P 1/4 0.014). Discussion: Agreement was found between taurine concentrations measured in dif-ferent additives, with expected higher concentration in WB than plasma. Taurine concentrations measured in heparinized plasma varied with sampling time point. Intraindividual daily variations were observed in all additives, but mainly in plasma samples. Conclusion: Taurine concentrations in dogs with suspected deficiency should be in-terpreted with caution. 2022 The Authors. Published by Elsevier B.V

    The epidemiology of upper respiratory tract disorders in a population of insured Swedish dogs (2011-2014), and its association to brachycephaly

    Get PDF
    Upper respiratory tract (URT) disorders are common in dogs but neither general nor breed-related epidemiological data are widely reported. This study ' s aims were to describe the epidemiology of URT disorders in a Swedish population of dogs and to investigate whether brachycephalic breeds were overrepresented among high-risk breeds. A cohort of dogs insured by Agria Djurforsakring in Sweden (2011-2014) was used to calculate overall and breed-specific incidence rate (IR), age at first URT diagnosis and relative risk (RR) for URT disorders. For breeds with high RR for URT disorders, co-morbidities throughout the dog's insurance period and age at death were investigated. The cohort included approximately 450,000 dogs. URT disorders had an overall IR of 50.56 (95% CI; 49.14-52.01) per 10,000 dog years at risk. Among 327 breeds, the English bulldog, Japanese chin, Pomeranian, Norwich terrier and pug had highest RR of URT disorders. Eight of 13 breeds with high RR for URT disorders were brachycephalic. The median age at first URT diagnosis was 6.00 years (interquartile range 2.59-9.78). French bulldogs with URT diagnoses had a significantly shorter life span (median = 3.61 years) than other breeds with URT diagnosis (median = 7.81 years). Dogs with high risk for URT disorders had more co-morbidities than average

    Discrimination of gamma rays due to inelastic neutron scattering in AGATA

    Full text link
    Possibilities of discriminating neutrons and gamma rays in the AGATA gamma-ray tracking spectrometer have been investigated with the aim of reducing the background due to inelastic scattering of neutrons in the high-purity germanium crystals. This background may become a serious problem especially in experiments with neutron-rich radioactive ion beams. Simulations using the Geant4 toolkit and a tracking program based on the forward tracking algorithm were carried out by emitting neutrons and gamma rays from the center of AGATA. Three different methods were developed and tested in order to find 'fingerprints' of the neutron interaction points in the detectors. In a simulation with simultaneous emission of six neutrons with energies in the range 1-5 MeV and ten gamma rays with energies between 150 and 1450 keV, the peak-to-background ratio at a gamma-ray energy of 1.0 MeV was improved by a factor of 2.4 after neutron rejection with a reduction of the photopeak efficiency at 1.0 MeV of only a factor of 1.25.Comment: Accepted for publication in Nuclear Instruments and Methods in Physics Research, A, 26 May 2009; 13 pages, 5 tables, 12 figure

    Digital pulse-shape discrimination of fast neutrons and gamma rays

    Full text link
    Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator detector, and a BaF2 detector was used to collect waveforms with a 100 Ms/s, 14 bit sampling ADC. Three identical ADC's were combined to increase the sampling frequency to 300 Ms/s. Four different digital pulse-shape analysis algorithms were developed and compared to each other and to data obtained with an analogue neutron-gamma discrimination unit. Two of the digital algorithms were based on the charge comparison method, while the analogue unit and the other two digital algorithms were based on the zero-crossover method. Two different figure-of-merit parameters, which quantify the neutron-gamma discrimination properties, were evaluated for all four digital algorithms and for the analogue data set. All of the digital algorithms gave similar or better figure-of-merit values than what was obtained with the analogue setup. A detailed study of the discrimination properties as a function of sampling frequency and bit resolution of the ADC was performed. It was shown that a sampling ADC with a bit resolution of 12 bits and a sampling frequency of 100 Ms/s is adequate for achieving an optimal neutron-gamma discrimination for pulses having a dynamic range for deposited neutron energies of 0.3-12 MeV. An investigation of the influence of the sampling frequency on the time resolution was made. A FWHM of 1.7 ns was obtained at 100 Ms/s.Comment: 26 pages, 14 figures, submitted to Nuclear Instruments and Methods in Physics Research

    Identification and rejection of scattered neutrons in AGATA

    Full text link
    Gamma rays and neutrons, emitted following spontaneous fission of 252Cf, were measured in an AGATA experiment performed at INFN Laboratori Nazionali di Legnaro in Italy. The setup consisted of four AGATA triple cluster detectors (12 36-fold segmented high-purity germanium crystals), placed at a distance of 50 cm from the source, and 16 HELENA BaF2 detectors. The aim of the experiment was to study the interaction of neutrons in the segmented high-purity germanium detectors of AGATA and to investigate the possibility to discriminate neutrons and gamma rays with the gamma-ray tracking technique. The BaF2 detectors were used for a time-of-flight measurement, which gave an independent discrimination of neutrons and gamma rays and which was used to optimise the gamma-ray tracking-based neutron rejection methods. It was found that standard gamma-ray tracking, without any additional neutron rejection features, eliminates effectively most of the interaction points due to recoiling Ge nuclei after elastic scattering of neutrons. Standard tracking rejects also a significant amount of the events due to inelastic scattering of neutrons in the germanium crystals. Further enhancements of the neutron rejection was obtained by setting conditions on the following quantities, which were evaluated for each event by the tracking algorithm: energy of the first and second interaction point, difference in the calculated incoming direction of the gamma ray, figure-of-merit value. The experimental results of tracking with neutron rejection agree rather well with Geant4 simulations

    Multiple shape coexistence in the nucleus 80^{80}Zr

    Get PDF
    We study the low-lying energy spectrum of the rp-process waiting point nucleus 80Zr with state-of-the-art beyond mean field methods with the Gogny D1S interaction. Symmetry restoration and configuration mixing of axial and triaxial shapes are included in the calculations. Five 0+ states corresponding to different nuclear shapes are obtained below 2.25 MeV and several rotational and {\gamma}- bands built upon them are identified. Nevertheless, these states do not modify the {\beta}-decay half-life having a negligible effect in the rp-process. A good agreement with the available experimental data is obtained.Comment: 6 pages, 3 figures, submitted to Physics Letters

    Urinary peptidome analyses for the diagnosis of chronic kidney disease in dogs

    Get PDF
    Chronic kidney disease (CKD) is clinically important in canine medicine. Current diagnostic tools lack sensitivity for detection of subclinical CKD. The aim of the present study was to evaluate urinary peptidome analysis for diagnosis of CKD in dogs. Capillary electrophoresis coupled to mass spectrometry analysis demonstrated presence of approximately 5400 peptides in dog urine. Comparison of urinary peptide abundance of dogs with and without CKD led to the identification of 133 differentially excreted peptides (adjusted P for each peptide <0.05). Sequence information was obtained for 35 of these peptides. This 35 peptide subset and the total group of 133 peptides were used to construct two predictive models of CKD which were subsequently validated by researchers masked to results in an independent cohort of 20 dogs. Both models diagnosed CKD with an area under the receiver operating characteristic (ROC) curve of 0.88 (95% confidence intervals [CI], 0.72–1.0). Most differentially excreted peptides represented fragments of collagen I, indicating possible association with fibrotic processes in CKD (similar to the equivalent human urinary peptide CKD model, CKD273). This first study of the urinary peptidome in dogs identified peptides that were associated with presence of CKD. Future studies are needed to validate the utility of this model for diagnosis and prediction of progression of canine CKD in a clinical setting

    Lifetime measurements in 63^{63}Co and 65^{65}Co

    Get PDF
    Lifetimes of the 9/219/2^-_1 and 3/213/2^-_1 states in 63^{63}Co and the 9/219/2^-_1 state in 65^{65}Co were measured using the recoil distance Doppler shift and the differential decay curve methods. The nuclei were populated by multi-nucleon transfer reactions in inverse kinematics. Gamma rays were measured with the EXOGAM Ge array and the recoiling fragments were fully identified using the large-acceptance VAMOS spectrometer. The E2 transition probabilities from the 3/213/2^-_1 and 9/219/2^-_1 states to the 7/27/2^- ground state could be extracted in 63^{63}Co as well as an upper limit for the 9/217/219/2^-_1\rightarrow7/2^-_1 BB(E2) value in 65^{65}Co. The experimental results were compared to large-scale shell-model calculations in the pfpf and pfg9/2pfg_{9/2} model spaces, allowing to draw conclusions on the single-particle or collective nature of the various states.Comment: 8 pages, 8 figures, 1 table, accepted for publication in Physical Review

    Longitudinal Analysis of Quality of Life, Clinical, Radiographic, Echocardiographic, and Laboratory Variables in Dogs with Preclinical Myxomatous Mitral Valve Disease Receiving Pimobendan or Placebo: The EPIC Study

    Get PDF
    Background: Changes in clinical variables associated with the administration of pimobendan to dogs with preclinical myxomatous mitral valve disease (MMVD) and cardiomegaly have not been described. Objectives: To investigate the effect of pimobendan on clinical variables and the relationship between a change in heart size and the time to congestive heart failure (CHF) or cardiac-related death (CRD) in dogs with MMVD and cardiomegaly. To determine whether pimobendan-treated dogs differ from dogs receiving placebo at onset of CHF. Animals: Three hundred and fifty-four dogs with MMVD and cardiomegaly. Materials and Methods: Prospective, blinded study with dogs randomized (ratio 1:1) to pimobendan (0.4-0.6 mg/kg/d) or placebo. Clinical, laboratory, and heart-size variables in both groups were measured and compared at different time points (day 35 and onset of CHF) and over the study duration. Relationships between short-term changes in echocardiographic variables and time to CHF or CRD were explored. Results: At day 35, heart size had reduced in the pimobendan group:median change in (Delta) LVIDDN -0.06 (IQR:-0.15 to + 0.02), P < 0.0001, and LA:Ao -0.08 (IQR:-0.23 to + 0.03), P < 0.0001. Reduction in heart size was associated with increased time to CHF or CRD. Hazard ratio for a 0.1 increase in Delta LVIDDN was 1.26, P = 0.0003. Hazard ratio for a 0.1 increase in Delta LA:Ao was 1.14, P = 0.0002. At onset of CHF, groups were similar. Conclusions and Clinical Importance: Pimobendan treatment reduces heart size. Reduced heart size is associated with improved outcome. At the onset of CHF, dogs treated with pimobendan were indistinguishable from those receiving placebo
    corecore