8 research outputs found
Relapsing Multiple Myeloma Manifested with Optic Nerve Sheath Involvement
Orbital and intraocular involvement of multiple myeloma(MM) is rare and usually indicates an aggressive course of disease. Here we report a case of relapsing MM which was diagnosed with optic nerve sheath involvement
Drug Delivery via the Suprachoroidal Space for the Treatment of Retinal Diseases
The suprachoroidal space (SCS), a potential space between the sclera and choroid, is becoming an applicable method to deliver therapeutics to the back of the eye. In recent years, a vast amount of research in the field has been carried out, with new discoveries in different areas of interest, such as imaging, drug delivery methods, pharmacokinetics, pharmacotherapies in preclinical and clinical trials and advanced therapies. The SCS can be visualized via advanced techniques of optical coherence tomography (OCT) in eyes with different pathologies, and even in healthy eyes. Drugs can be delivered easily and safely via hollow microneedles fitted to the length of the approximate thickness of the sclera. SCS injections were found to reach greater baseline concentrations in the target layers compared to intravitreal (IVT) injection, while agent clearance was faster with highly aqueous soluble molecules. Clinical trials with SCS injection of triamcinolone acetonide (TA) were executed with promising findings for patients with noninfectious uveitis (NIU), NIU implicated with macular edema and diabetic macular edema (DME). Gene therapy is evolving rapidly with viral and non-viral vectors that were found to be safe and efficient in preclinical trials. Here, we review these novel different aspects and new developments in clinical treatment of the posterior segment of the eye
Gonioscopy-assisted transluminal trabeculotomy in patients with advanced glaucoma
Purpose: To evaluate the efficacy and safety of gonioscopy-assisted transluminal trabeculotomy (GATT) in patients with advanced glaucoma. Methods: Records of 46 patients with advanced glaucoma were reviewed retrospectively in this single-center chart review. The main outcome measure was surgical success; intra-ocular pressure (IOP) and IOP lowering medication use were secondary outcome measures. Success was defined as an IOP of 18 mmHg or lower (criterion A) or 14 mmHg or lower (criterion B) and one of the following: IOP reduction >30% from baseline on the same or fewer medications or IOP ≤ of baseline on fewer medications as compared to baseline. Results: Forty-seven eyes were included in the analysis. The average mean deviation was -17.5 ± 7.2 dB (range −8.0 to -33.0). The average follow-up was 6.8 months (range 3.2–22.3). Success at 6 months was 91% for criterion A and 75% for criterion B (n = 33). Mean IOP was reduced from 19.3 ± 6 mmHg (12–40) on 3.7 ± 1.4 medications to 13.2 ± 5.8 mmHg on 1.6 ± 1.4 medications at the 6th post-operative month (P < 0.001 for both IOP and medications). At the last follow-up visit, 37 patients (78%) had an IOP of 14 mmHg or lower, and ten of these patients were unmedicated. Transient hyphema and IOP spikes were the most prevalent adverse events following surgery. Three eyes required further surgery for IOP control. None of the patients lost vision because of surgery. Conclusions: GATT is a viable surgical option in cases of advanced glaucoma. Careful patient selection and attentive post-operative management are imperative
Peak Occurrence of Retinal Detachment following Cataract Surgery: A Systematic Review and Pooled Analysis with Internal Validation
Introduction. Timing of retinal detachment (RD) following cataract surgery is of importance for both diagnostic and prognostic factors. However, results on RD onset-time following cataract surgery have been conflicting. Method. A systematic pooled analysis of the literature regarding timing of retinal detachment following cataract surgery. Outcomes were verified against an independent dataset. Results. Twenty-one studies, reporting on rates of RD in 3,352,094 eyes of 2,458,561 patients, met our inclusion criteria and were included in the analysis. The mean pooled time to RD following surgery was 23.12 months (95% CI: 17.79–28.45 months) with high heterogeneity between studies (I2=100%, P<0.00001). Meta-analytic pooling for the risk of retinal detachment revealed a risk of 1.167% (95% CI: 0.900 to 1.468, I2=99.50%, P<0.0001). A retrospective chart review identified 54 pseudophakic RD cases (mean age 65.5, 59.3% males). The 95% confidence interval for the mean time to RD was 3.1–6.75 years. Conclusions. The interval between cataract surgery and RD in a pooled analysis revealed a mean time of approximately 1.5–2.3 years. However, there was high variability between studies. Validation based on our local results showed similar yet slightly longer time frames. Timing of pseudophakic retinal detachment might direct appropriate follow-up, assisting in earlier detection
Comparison of the Usability of Eye Drop Aids and the Conventional Bottle
(1) Background: Eye drops are the most common route of administration for ophthalmic medications. Administering drops can be a major hurdle for patients, potentially resulting in noncompliance and treatment failure. The purpose of this study is to compare the efficacy and safety of two different aids and the conventional bottle for eye drop instillation; (2) Methods: An interventional crossover study involving standard eye drop bottle, Opticare aid and Autodrop aid. The study included healthy subjects without a history of regular eye drop use; (3) Results: Twenty-six subjects were enrolled. Of those subjects, 96% and 92% were able to assemble the eye drop bottle into the Autodrop and the Opticare aids, respectively. Subjective assessment indicated that Autodrop was significantly easier to assemble than Opticare (95% CI: −1.6802 to −0.1659, p = 0.02). When using either aid, there was no contamination of the bottle tip, which occurred in 46% of subjects when no aid was used (p = 0.0005). Fewer drops were expelled when using the conventional bottle as compared to the aids (p = 0.05 compared to Autodrop, p = 0.1 compared to Opticare); (4) Conclusions: Autodrop and Opticare can assist patients with eye drop placement. These aids completely prevented bottle tip contamination, which was frequently observed when the conventional bottle was used alone
Secondary bacterial infection in COVID-19 patients is a stronger predictor for death compared to influenza patients
Abstract Secondary bacterial infections are a potentially fatal complication of influenza infection. We aimed to define the impact of secondary bacterial infections on the clinical course and mortality in coronavirus disease 2019 (COVID-19) patients by comparison with influenza patients. COVID-19 (n = 642) and influenza (n = 742) patients, admitted to a large tertiary center in Israel and for whom blood or sputum culture had been taken were selected for this study. Bacterial culture results, clinical parameters, and death rates were compared. COVID-19 patients had higher rates of bacterial infections than influenza patients (12.6% vs. 8.7%). Notably, the time from admission to bacterial growth was longer in COVID-19 compared to influenza patients (4 (1–8) vs. 1 (1–3) days). Late infections (> 48 h after admission) with gram-positive bacteria were more common in COVID-19 patients (28% vs. 9.5%). Secondary infection was associated with a higher risk of death in both patient groups 2.7-fold (1.22–5.83) for COVID-19, and 3.09-fold (1.11–7.38) for Influenza). The association with death remained significant upon adjustment to age and clinical parameters in COVID-19 but not in influenza infection. Secondary bacterial infection is a notable complication associated with worse outcomes in COVID-19 than influenza patients. Careful surveillance and prompt antibiotic treatment may benefit selected patients