32 research outputs found

    Design and test of a multi-coil helical evaporator for a high temperature organic Rankine cycle plant driven by biogas waste heat

    Get PDF
    A direct evaporator for a high temperature organic Rankine cycle (ORC) plant with toluene as a working fluid is designed and tested. The exhaust gas from a 800 kWe combined heat and power plant is cooled on the shell side of the present heat exchanger, while the working fluid is heated and evaporated within eight helically coiled tubes, constituting a tube bundle. A method to obtain optimal design parameters for this type of heat exchanger is presented, considering the heat source, the ORC and the available space at the test site. After manufacturing, the apparatus is tested to validate the design procedure, focusing on the employed heat transfer and pressure loss correlations on the shell side. It is shown that the predicted values of the overall heat transfer coefficient and the shell side Nusselt number are in good agreement with experimental data, showing a maximum deviation of 5.5%. The measured shell side pressure loss is slightly higher than the predicted value, indicating that the correlation underestimates the pressure loss coefficient by up to 7% at low Reynolds numbers, but has a good accuracy at higher Reynolds numbers. It is observed that it is essential to adjust the mass flow rate of the working fluid in each coil to obtain a homogenous vapor quality. A reliable operation of the direct evaporator with a maximum heat flow of 225 kW is shown

    Individualised perioperative blood pressure and fluid therapy in oesophagectomy:study protocol for a randomised clinical trial

    Get PDF
    INTRODUCTION: Oesophagectomy is the mainstay of curative treatment for oesophageal cancer, but it is associated with a high risk of major complications. Goal-directed fluid therapy and individualised blood pressure management may prevent complications after surgery. Extending goal-directed fluid therapy after surgery and applying an individual blood pressure target may have substantial benefit in oesophagectomy. This is a protocol for a clinical trial implementing a novel haemodynamic protocol from the start of anaesthesia to the next day with the patient’s own night-time blood pressure as the lower threshold.METHODS: This is a single-centre, single-blind, randomised, clinical trial. Oesophagectomy patients are randomised 1:1 for either perioperative haemodynamic management according to a goal-directed fluid therapy protocol with an individual target blood pressure or for standard care. The primary endpoint is the total burden of morbidity and mortality assessed by the Comprehensive Complication Index 30 days after surgery. Secondary endpoints are complications, reoperations, fluid and vasopressor dosage and quality of life at 90 days after surgery.CONCLUSIONS: The results from this trial provide an objective and easy-to-follow algorithm for fluid administration, which may improve patient-centred outcomes in oesophagectomy patients.</p

    NfL reliability across laboratories, stage-dependent diagnostic performance and matrix comparability in genetic FTD: a large GENFI study

    Get PDF
    BACKGROUND: Blood neurofilament light chain (NfL) is increasingly considered as a key trial biomarker in genetic frontotemporal dementia (gFTD). We aimed to facilitate the use of NfL in gFTD multicentre trials by testing its (1) reliability across labs; (2) reliability to stratify gFTD disease stages; (3) comparability between blood matrices and (4) stability across recruiting sites. METHODS: Comparative analysis of blood NfL levels in a large gFTD cohort (GENFI) for (1)-(4), with n=344 samples (n=148 presymptomatic, n=11 converter, n=46 symptomatic subjects, with mutations in C9orf72, GRN or MAPT; and n=139 within-family controls), each measured in three different international labs by Simoa HD-1 analyzer. RESULTS: NfL revealed an excellent consistency (intraclass correlation coefficient (ICC) 0.964) and high reliability across the three labs (maximal bias (pg/mL) in Bland-Altman analysis: 1.12±1.20). High concordance of NfL across laboratories was moreover reflected by high areas under the curve for discriminating conversion stage against the (non-converting) presymptomatic stage across all three labs. Serum and plasma NfL were largely comparable (ICC 0.967). The robustness of NfL across 13 recruiting sites was demonstrated by a linear mixed effect model. CONCLUSIONS: Our results underline the suitability of blood NfL in gFTD multicentre trials, including cross-lab reliable stratification of the highly trial-relevant conversion stage, matrix comparability and cross-site robustness

    Measurement of the charge asymmetry in top-quark pair production in the lepton-plus-jets final state in pp collision data at s=8TeV\sqrt{s}=8\,\mathrm TeV{} with the ATLAS detector

    Get PDF
    corecore