206 research outputs found

    Temperature dependence of Mott transition in VO_2 and programmable critical temperature sensor

    Full text link
    The temperature dependence of the Mott metal-insulator transition (MIT) is studied with a VO_2-based two-terminal device. When a constant voltage is applied to the device, an abrupt current jump is observed with temperature. With increasing applied voltages, the transition temperature of the MIT current jump decreases. We find a monoclinic and electronically correlated metal (MCM) phase between the abrupt current jump and the structural phase transition (SPT). After the transition from insulator to metal, a linear increase in current (or conductivity) is shown with temperature until the current becomes a constant maximum value above T_{SPT}=68^oC. The SPT is confirmed by micro-Raman spectroscopy measurements. Optical microscopy analysis reveals the absence of the local current path in micro scale in the VO_2 device. The current uniformly flows throughout the surface of the VO_2 film when the MIT occurs. This device can be used as a programmable critical temperature sensor.Comment: 4 pages, 3 figure

    ECG measurement on a chair without conductive contact

    Get PDF
    For the purpose of long-term, everyday electrocardiogram (ECG) monitoring, we present a convenient method of ECG measurement without direct conductive contact with the skin while subjects sat on a chair wearing normal clothes. Measurements were made using electrodes attached to the back of a chair, high-input-impedance amplifiers mounted on the electrodes, and a large ground-plane placed on the chair seat. ECGs were obtained by the presented method for several types of clothing and compared to ECGs obtained from conventional measurement using Ag-AgCl electrodes. Motion artifacts caused by usual desk works were investigated. This study shows the feasibility of the method for long-term, convenient, everyday use

    Observation of First-Order Metal-Insulator Transition without Structural Phase Transition in VO_2

    Full text link
    An abrupt first-order metal-insulator transition (MIT) without structural phase transition is first observed by current-voltage measurements and micro-Raman scattering experiments, when a DC electric field is applied to a Mott insulator VO_2 based two-terminal device. An abrupt current jump is measured at a critical electric field. The Raman-shift frequency and the bandwidth of the most predominant Raman-active A_g mode, excited by the electric field, do not change through the abrupt MIT, while, they, excited by temperature, pronouncedly soften and damp (structural MIT), respectively. This structural MIT is found to occur secondarily.Comment: 4 pages, 4 figure

    Monoclinic and Correlated Metal Phase in VO_2 as Evidence of the Mott Transition: Coherent Phonon Analysis

    Full text link
    In femtosecond pump-probe measurements, the appearance of coherent phonon oscillations at 4.5 THz and 6.0 THz indicating the rutile metal phase of VO_2 does not occur simultaneously with the first-order metal-insulator transition (MIT) near 68^oC. The monoclinic and correlated metal(MCM) phase between the MIT and the structural phase transition (SPT) is generated by a photo-assisted hole excitation which is evidence of the Mott transition. The SPT between the MCM phase and the rutile metal phase occurs due to subsequent Joule heating. The MCM phase can be regarded as an intermediate non-equilibrium state.Comment: 4 pages, 2 figure

    Bare-metal stents versus drug-eluting stents in large (≥3.5mm) single coronary artery: Angiographic and clinical outcomes at 6 months

    Get PDF
    SummaryBackgroundAlthough drug-eluting stents (DES) have been shown to dramatically reduce restenosis and improve the rate of event-free survival in large randomized trials, the benefit of DES appears to be limited to restenosis. In large arteries, it is not clear which type of stent is more superior in angiographic and clinical outcomes between DES and bare-metal stents (BMS). We compared the angiographic and clinical outcomes of DES versus BMS in large arteries (≥3.5mm).MethodTwo hundred and forty patients from March 2002 to March 2007 received stents; 196 patients were treated with DES (44.9% sirolimus-eluting stents; 43.9% paclitaxel-eluting stents; 11.2% zotarolimus-eluting stents) and 44 with cobalt–chromium BMS for single de novo lesions in a large vessel. All subjects received aspirin, clopidogrel, and/or cilostazol as the standard antiplatelet regimen. The angiographic and clinical outcomes were evaluated at 6 months.ResultsFor the baseline characteristics, there were no significant differences between the DES and BMS groups. In addition, for the initially implanted stent there was no difference in the length, stent diameter, and lesion site between the two groups. After 6 months, the follow-up angiogram showed that in-stent diameter restenosis and late loss was more common with BMS than DES (39±21% vs. 19±17%, p=0.007; 1.44±0.83mm vs. 0.62±0.58mm, p=0.009, respectively). However, the target-lesion revascularization/target-vessel revascularization, and total major adverse cardiac events showed no significant differences between the groups (5.3% vs. 3.6%, p=0.62; 5.3% vs. 4.6%, p=0.86, respectively).ConclusionThe DES and cobalt–chromium BMS placed in large coronary arteries showed equally favorable 6-month clinical outcomes, although the 6-month angiographic results appeared more favorable in the DES group than in the BMS group

    Effects and Safety of Gyejibongnyeong-Hwan on Dysmenorrhea Caused by Blood Stagnation: A Randomized Controlled Trial

    Get PDF
    Objective. This study was a multicenter, randomized, double-blind, and controlled trial with two parallel arms: the GJBNH group and the placebo group. This trial recruited 100 women aging 18 to 35 years with primary dysmenorrhea caused by blood stagnation. The investigational drugs, GJBNH or placebo, were administered for two menstrual periods (8 weeks) to the participants three times per day. The participants were followed up for two menstrual cycles after the administration. Results. The results were analyzed by the intention-to-treat (ITT) dataset and the per-protocol (PP) dataset. In the ITT dataset, the change of the average menstrual pain VAS score in the GJBNH group was statistically significantly lower than that in the control group. Significant difference was not observed in the SF-MPQ score change between the GJBNH group and the placebo group. No significant difference was observed in the PP analyses. In the follow-up phase, the VAS scores of the average menstrual pain and the maximum menstrual pain continually decreased in the placebo group, but they increased in the GJBNH group. Conclusion. GJBNH treatment for eight weeks improved the pain of the dysmenorrhea caused by blood stagnation, but it should be successively administered for more than two menstrual cycles. Trial Registration. This trial is registered with Current Controlled Trials no. ISRCTN30426947

    LTCC-Based DC-DC Converter for Reduction of Switching Noise and Radiated Emissions

    Get PDF
    In this study, a low-temperature co-fired ceramic (LTCC)-based direct current (DC)-DC converter is proposed for reducing stray inductance and mitigating electromagnetic interference. The dominant radiating loop of the proposed LTCC-based DC-DC converter features a multilayer design, which helps suppress noise sources and reduce radiated emissions. The peak voltage of switching noise for the proposed DC-DC converter at the frequency of 500 kHz is approximately 8.98% lower than that of a conventional DC-DC converter. In addition, the radiated emission level of the proposed DC-DC converter is lower than that of the conventional DC-DC converter. In sum, the proposed LTCC-technology-based multilayer design reduces the peak voltage of switching noise and the radiated emission of the DC-DC converter
    corecore