14 research outputs found

    Assessment of Biventricular Myocardial Function with 2-Dimensional Strain and Conventional Echocardiographic Parameters: A Comparative Analysis in Healthy Infants and Patients with Severe and Critical Pulmonary Stenosis

    No full text
    Our aim was to compare the global longitudinal and regional biventricular strain between infants with severe and critical pulmonary stenosis (PS), and controls; to compare pre- and post-procedural strain values in infants with severe and critical PS; and to assess the correlations between echocardiographic strain and conventional parameters. We conducted a retrospective single-center study. The comparisons of echocardiographic variables were performed using separate linear mixed models. The overall mean right ventricle (RV) regional strains measured before intervention in PS patients was significantly different when compared to the control group (p = 0.0324). We found a significant change in the left ventricle, RV, and inter-ventricular septum strain (IVS) values from basal to apical location (p < 0.05). IVS strain values showed a higher decrease in mean strain values from basal to apical in PS patients. There was no significant difference in means of baseline and post-interventional strain values in PS patients (p > 0.05). Following the strain analysis in patients with PS, we obtained statistically significant changes in the RV global-4-chamber longitudinal strain (RV4C). The RV4C, which quantifies the longitudinal strain to the entire RV, can be used in current clinical practice for the evaluation of RV function in infants with severe and critical PS. The longitudinal and segmental strain capture the pathological changes in the IVS, modifications that cannot be highlighted through a classical echocardiographic evaluation

    GATA4 rs61277615, rs73203482, and rs35813172 in Newborns with Transposition of the Great Arteries

    Get PDF
    Congenital heart disease is the most common malformative pathology in newborns, with a worldwide incidence at 0.4-5%. We investigated the possible relationship between variations in nucleotide sequences and specific cardiac malformations in the GATA-binding factor 4 (GATA4) exon 1 region by using Sanger sequencing. Forty-four newborns from a third-level neonatal intensive care unit who were diagnosed with nonsyndromic, ductal-dependent congenital heart disease (i.e., transposition of the great arteries or ductal-dependent coarctation of the aorta) were enrolled. Their DNA was extracted using commercial methods and tested using the multiplex ligation-dependent probe amplification (MLPA) technique. The Sanger sequencing for GATA4 exon 1 in the newborns’ DNA identified rs61277615, rs73203482, and rs35813172 variants not reported in the ClinVar archive of human variations in newborns previously diagnosed with transposition of the great arteries (n=5) and coarctation of the aorta (n=1). The identification of these novel variants in newborns with transposition of the great arteries or ductal-dependent coarctation of the aorta may be the first step in determining the variants’ contribution to the occurrence of congenital heart disease. However, these results may be inconclusive, since the observed variants within GATA4 gene were not previously reported

    Fetal Tachyarrhythmia Management from Digoxin to Amiodarone—A Review

    No full text
    Sustained fetal tachycardias are rare but represent a high risk of mortality and morbidity. Consensus has yet to be found regarding their optimal management. The aim of this narrative review is to summarize the data available in the current literature regarding the efficacy and safety of medications used in the management of intrauterine tachyarrhythmias and to provide possible treatment protocols. In this review, we would like to emphasize the importance of a thorough evaluation of both the fetus and the mother, prior to transplacental antiarrhythmic drug initiation. Factors such as the hemodynamic status of the fetus, possible mechanisms of fetal arrhythmia, and concomitant maternal conditions are of primordial importance. As a possible treatment protocol, we would like to recommend the following: due to the risk of sustained supraventricular tachycardia (SVT), fetuses with frequent premature atrial beats should be evaluated more frequently by echocardiography. A careful hemodynamic evaluation of a fetus with tachycardia is primordial in forestalling the appearance of hydrops. In the case of atrial flutter (AFL), sotalol therapy could represent a first choice, whereas when dealing with SVT patients, flecainide should be considered, especially for hydropic patients. These data require consolidation through larger scale, non-randomized studies and should be handled with caution

    Total Anomalous Pulmonary Venous Connection in Children

    No full text
    Introduction: The aim of this study was to study the anatomical types of total anomalous pulmonary venous connection (TAPVC), the associated cardiac and extracardiac congenital malformations, clinical manifestations, and postoperative evolution

    Cantrell Syndrome—A Rare Complex Congenital Anomaly: A Case Report and Literature Review

    Get PDF
    Cantrell syndrome (CS) or pentalogy of Cantrell is defined as a rare condition involving a midline anterior abdominal wall defect, a distal sternal cleft, a defect of the anterior diaphragm, and a defect of the apical pericardium with pericardio-peritoneal communication, as well as intracardiac anomalies. We report the case of a male newborn with type 2 CS diagnosed during intrauterine life based on ultrasonographic evaluation. Clinical examination at birth revealed an abdominal wall defect with extrathoracic displacement of the heart and a diastasis of the sagittal suture. Postnatal echocardiography revealed tricuspid atresia, partial extrathoracic and extra-abdominal displacement of the heart and liver, a large ventricular septal defect, severe subpulmonary stenosis, hypoplasia of the pulmonary artery, and a large hourglass-shaped left ventricle secondary to narrowing of the heart at the level of its extrathoracic displacement. Computed tomography showed additional abnormalities including increased left ventricular volume with extrathoracic apical aneurysmal dilatation below the xiphoid process at the level of anterior abdominal wall, a hypoplastic right ventricle, partial transparietal herniation of the left hepatic lobe adjacent to a left ventricular diverticulum, and an adrenal hematoma. The newborn received intensive medical management during his first week of life; however, surgical management had to be postponed owing to his unstable condition. Eventually, it was performed on the 14th day of life, but unfortunately, the newborn died shortly after the procedure

    Comparative assessment of myocardial function between late premature newborns and term neonates using the 2D speckle tracking method

    No full text
    IntroductionAssessment of myocardial function through speckle tracking echocardiography (STE) can bring benefits to conventional echocardiography in premature newborns, a particular vulnerable group in terms of adaptation to extra-uterine life. Furthermore, it represents a non-invasive imagistic method which can guide therapeutic approach in the hemodynamically unstable newborn. This study aims to highlight the particularities of myocardial function in late premature newborns, by conducting a comparison with a group of healthy neonates, by using STE.MethodsConducted over a timespan of two years, this prospective study enrolled 64 term neonates and 21 premature newborns, with gestational ages ranging between 28 and 36 weeks, who prior to discharge underwent a cardiac ultrasound, involving two-dimensional image acquisitions of the apical four-chamber view of both ventricles. Afterwards, the images were offline analyzed, by using the autostrain function.ResultsAfter segmental strain analysis, no significant discrepancies between the two groups in terms of interventricular values were found. However, left ventricle and right ventricle strain measurements differed significantly (p < 0.01), for each of the analyzed segments (basal, medial or apical). Moreover, a linear increase in interventricular (IV) basal strain with corrected gestational age progression was noted (p = 0.04). Peak global longitudinal strain (pGLS) and EF were similar between the two study groups. Premature newborns presented significantly more negative mean values of right ventricular free wall longitudinal strain (RVFWSL), (−24.19 ± 4.95 vs. −18.05 ± 5.88, p < 0.01) and of right ventricle global four chamber longitudinal strain (RV4CSL), (−19.71 ± 3.62 vs. −15.46 ± 5.59, p < 0.01), when compared to term neonates.ConclusionsThe 2D STE is a reliable method for cardiac assessment of late preterm newborns. The evaluation of two-dimensional global longitudinal LV and RV strains might represent a useful tool in clinical practice. A better response of the right ventricle to the longitudinal deformation within premature neonates was noted. Thus, this study facilitates the identification of accurate reference values for this particular population segment, which will enable the evaluation of ventricular function in premature newborns with concurring disorders. Future longitudinal studies, assessing the fetal heart, could provide more insight into the development of myocardial function

    A rare case of cerebral hemorrage in a pre-term infant with coarctation of the aorta

    Get PDF
    Introduction. Coarctation of the aorta (CoA) occurs in 6-8% of patients with congenital heart disease, with an incidence of 4/10,000 live births. It can be present with various clinical pictures, in an age range between newborn and adolescence. Infants with birth weights ≤ 2 kg with CoA have increased risk of severe intraventricular hemorrhage (IVH) compared to their birth weight-matched cohorts. Case presentation. We present a case of a premature, male newborn, with low birth weight, who at the age of 3 weeks developed signs and symptoms of cardiogenic shock. Clinical examination, echocardiography and angio-CT confirmed the diagnosis of a severe CoA, without any flow through the ductus arteriosus. Treatment with prostaglandin E1 was initiated, to promote ductal patency. The systolic blood pressures were above 99 percentile for his gestational age in the upper extremities, with a noninvasive pressure gradient around 86 mmHg between the arm and leg. Transfontanellar ultrasonography evaluation revealed a grade II/III bilateral IVH, in resorption, with cystic transformation. At the age of 6 weeks definitive surgical repair was performed. Postoperatively, at the 3 month follow-up, the clinical suspicion of recoarctation of the aorta arised, confirmed by echocardiography and angio-CT, with arterial hypertension and gradient around 37 mmHg between the arm and leg. Prosthetic patch aortoplasty was performed. The postoperative evolution was marked by the persistence of arterial hypertension, the infant requiring continued treatment with angiotensin-converting enzyme inhibitor. Conclusions. Premature neonates with low birth weight have always constituted a medical management challenge, with short and long term implications. A strong point in solving such cases is a multidisciplinary medical for assessment, management and outcomes

    Assessment of Biventricular Myocardial Function with 2-Dimensional Strain and Conventional Echocardiographic Parameters: A Comparative Analysis in Healthy Infants and Patients with Severe and Critical Pulmonary Stenosis

    No full text
    Our aim was to compare the global longitudinal and regional biventricular strain between infants with severe and critical pulmonary stenosis (PS), and controls; to compare pre- and post-procedural strain values in infants with severe and critical PS; and to assess the correlations between echocardiographic strain and conventional parameters. We conducted a retrospective single-center study. The comparisons of echocardiographic variables were performed using separate linear mixed models. The overall mean right ventricle (RV) regional strains measured before intervention in PS patients was significantly different when compared to the control group (p = 0.0324). We found a significant change in the left ventricle, RV, and inter-ventricular septum strain (IVS) values from basal to apical location (p p > 0.05). Following the strain analysis in patients with PS, we obtained statistically significant changes in the RV global-4-chamber longitudinal strain (RV4C). The RV4C, which quantifies the longitudinal strain to the entire RV, can be used in current clinical practice for the evaluation of RV function in infants with severe and critical PS. The longitudinal and segmental strain capture the pathological changes in the IVS, modifications that cannot be highlighted through a classical echocardiographic evaluation

    Diagnostic Difficulties in a Case of Fetal Ventricular Tachycardia Associated with Neonatal COVID Infection: Case Report

    No full text
    The clinical course of COVID in the pediatric population is considered to be much milder when compared to adults; however, the occurrence of severe and fatal forms of the disease in children is non-negligible, especially in patients with comorbidities such as prematurity or cardiac disease. We report a case of a newborn with sotalol-controlled fetal ventricular tachycardia, who was postnatally diagnosed with COVID infection. The myocardial injury was sustained on the basis of pericardial effusion, left ventricular dysfunction, rapid progression to coronary artery dilation, and an arrhythmic storm. We believe that, in our case, there is a significant overlap between fetal ventricular tachycardia, associated with impaired left ventricular function, and COVID infection, diagnosed after birth; both factors contribute to the myocardial dysfunction with a fulminant clinical evolution. To our knowledge, this is the first case describing neonatal myocardial dysfunction associated with SARS-CoV infection complicating the clinical course of rare fetal tachyarrhythmia
    corecore