4 research outputs found

    Application of computational fluid dynamics on a study in swine facilities with mechanical ventilation system

    No full text
    Ventilation systems used in swine facilities deserve to be studied because they directly affect productivity in the pig farming sector. Bearing this in mind the uniformity of air distribution and temperature is essential to animal welfare in this breeding environment. Thus, the purpose of this study was to identify whether changes in air entrances and exhaust fan positioning could influence air velocity and temperature distribution. The experimental data were collected in a commercial full-scale sow facility. Validation was carried out by comparing the simulated air temperatures and data measured in the field. These results showed agreement between data with a maximum relative error of approximately 3 %. The real settings showed a gradual increase in the air velocity from the air entrances and dead zones due to the change in airflow direction. There was no difference when the positioning of the exhaust fans was altered or was maintained in the original air entrances. The proposed arrangement with only one air inlet reduced the areas of low air movement as a consequence of the change in flow direction. Furthermore, the variables have the same pattern along the transversal plane. The simulations showed that the position of the air inlets had a higher influence on temperature distribution.753173183CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO - CNPQSem informaçã

    Application of computational fluid dynamics on a study in swine facilities with mechanical ventilation system

    No full text
    ABSTRACT: Ventilation systems used in swine facilities deserve to be studied because they directly affect productivity in the pig farming sector. Bearing this in mind the uniformity of air distribution and temperature is essential to animal welfare in this breeding environment. Thus, the purpose of this study was to identify whether changes in air entrances and exhaust fan positioning could influence air velocity and temperature distribution. The experimental data were collected in a commercial full-scale sow facility. Validation was carried out by comparing the simulated air temperatures and data measured in the field. These results showed agreement between data with a maximum relative error of approximately 3 %. The real settings showed a gradual increase in the air velocity from the air entrances and dead zones due to the change in airflow direction. There was no difference when the positioning of the exhaust fans was altered or was maintained in the original air entrances. The proposed arrangement with only one air inlet reduced the areas of low air movement as a consequence of the change in flow direction. Furthermore, the variables have the same pattern along the transversal plane. The simulations showed that the position of the air inlets had a higher influence on temperature distribution

    Application of computational fluid dynamics on a study in swine facilities with mechanical ventilation system

    No full text
    <div><p>ABSTRACT: Ventilation systems used in swine facilities deserve to be studied because they directly affect productivity in the pig farming sector. Bearing this in mind the uniformity of air distribution and temperature is essential to animal welfare in this breeding environment. Thus, the purpose of this study was to identify whether changes in air entrances and exhaust fan positioning could influence air velocity and temperature distribution. The experimental data were collected in a commercial full-scale sow facility. Validation was carried out by comparing the simulated air temperatures and data measured in the field. These results showed agreement between data with a maximum relative error of approximately 3 %. The real settings showed a gradual increase in the air velocity from the air entrances and dead zones due to the change in airflow direction. There was no difference when the positioning of the exhaust fans was altered or was maintained in the original air entrances. The proposed arrangement with only one air inlet reduced the areas of low air movement as a consequence of the change in flow direction. Furthermore, the variables have the same pattern along the transversal plane. The simulations showed that the position of the air inlets had a higher influence on temperature distribution.</p></div
    corecore