45,796 research outputs found

    CONDITION-BASED RISK ASSESSMENT STRATEGY AND ITS HEALTH INDICATOR WITH APPLICATION TO PUMPS AND COMPRESSORS

    Get PDF
    Large rotating machinery, such as centrifugal gas compressors and pumps, are widely applied as crucial components in the petrochemical industries. To enable in-time and effective maintenance of these machines, the concept of a health indicator is arousing great interest. A suitable health indicator indicates the overall health of the machinery and it is closely related to maintenance strategies and decision-making. It can be obtained either from near misses and incident data, or from real-time measured data. However, the existing health indicators have some limitations. On the one hand, the near misses and incident data may have been obtained from similar systems, reflecting population characteristics but not fully accounting for the individual features of the target system. On the other hand, the existing health indicators that use condition monitoring data, mainly focused on detecting incipient faults, and usually do not include financial cost factors when calculating the indicators. Therefore, there is the requirement to develop a single system "Health Indicator", that can show the health condition of a system in real-time, as well as the likely financial loss incurred when a fault is detected in the system, to assist operators on maintenance decision making. This project has developed such an integrated health indicator for rotating machinery. The integrated health indicator described in this thesis is extracted from a novel condition-based risk assessment strategy, which can be regarded as an integration of risk-based maintenance with improved conventional condition-based maintenance, with financial factors taken into account. The value of the health indicator is that it directly illustrates the risk to the system (or equipment), including likely financial loss, which makes it easier for operators to select the optimal time for maintenance or set alarm thresholds given the specific conditions in their companies or plants. This thesis provides a guide to set up an integrated maintenance model for large rotating machinery. It provides a useful reference for researchers working on condition-based fault detection and dynamic risk-based maintenance

    On passivity and passification of stochastic fuzzy systems with delays: The discrete-time case

    Get PDF
    Copyright [2010] IEEE. This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to [email protected]. By choosing to view this document, you agree to all provisions of the copyright laws protecting it.Takagi–Sugeno (T-S) fuzzy models, which are usually represented by a set of linear submodels, can be used to describe or approximate any complex nonlinear systems by fuzzily blending these subsystems, and so, significant research efforts have been devoted to the analysis of such models. This paper is concerned with the passivity and passification problems of the stochastic discrete-time T-S fuzzy systems with delay. We first propose the definition of passivity in the sense of expectation. Then, by utilizing the Lyapunov functional method, the stochastic analysis combined with the matrix inequality techniques, a sufficient condition in terms of linear matrix inequalities is presented, ensuring the passivity performance of the T-S fuzzy models. Finally, based on this criterion, state feedback controller is designed, and several criteria are obtained to make the closed-loop system passive in the sense of expectation. The results acquired in this paper are delay dependent in the sense that they depend on not only the lower bound but also the upper bound of the time-varying delay. Numerical examples are also provided to demonstrate the effectiveness and feasibility of our criteria.This work was supported in part by the Royal Society Sino–British Fellowship Trust Award of the U.K., by the National Natural Science Foundation of China under Grant 60804028, by the Specialized Research Fund for the Doctoral Program of Higher Education for New Teachers in China under Grant 200802861044, and by the Teaching and Research Fund for Excellent Young Teachers at Southeast University of China

    Spacelike hypersurfaces with negative total energy in de Sitter spacetime

    Full text link
    De Sitter spacetime can be separated into two parts along two kinds of hypersurfaces and the half-de Sitter spacetimes are covered by the planar and hyperbolic coordinates respectively. Two positive energy theorems were proved previously for certain \P-asymptotically de Sitter and \H-asymptotically de Sitter initial data sets by the second author and collaborators. These initial data sets are asymptotic to time slices of the two kinds of half-de Sitter spacetimes respectively, and their mean curvatures are bounded from above by certain constants. While the mean curvatures violate these conditions, the spacelike hypersurfaces with negative total energy in the two kinds of half-de Sitter spacetimes are constructed in this short paper.Comment: 11 pages, final version, to appear in J. Math. Phy
    corecore