20 research outputs found

    Scalable deterministic integration of two quantum dots into an on-chip quantum circuit

    Full text link
    Integrated quantum photonic circuits (IQPCs) with deterministically integrated quantum emitters are critical elements for scalable quantum information applications and have attracted significant attention in recent years. However, scaling up them towards fully functional photonic circuits with multiple deterministically integrated quantum emitters to generate photonic input states remains a great challenge. In this work, we report on a monolithic prototype IQPC consisting of two pre-selected quantum dots deterministically integrated into nanobeam cavities at the input ports of a 2x2 multimode interference beam-splitter. The on-chip beam splitter exhibits a splitting ratio of nearly 50/50 and the integrated quantum emitters have high single-photon purity, enabling on-chip HBT experiments, depicting deterministic scalability. Overall, this marks a cornerstone toward scalable and fully-functional IQPCs

    Controllable Spin-Resolved Photon Emission Enhanced by Slow-Light Mode in Photonic Crystal Waveguides on Chip

    Full text link
    We report the slow-light enhanced spin-resolved in-plane emission from a single quantum dot (QD) in a photonic crystal waveguide (PCW). The slow light dispersions in PCWs are designed to match the emission wavelengths of single QDs. The resonance between two spin states emitted from a single QD and a slow light mode of a waveguide is investigated under a magnetic field with Faraday configuration. Two spin states of a single QD experience different degrees of enhancement as their emission wavelengths are shifted by combining diamagnetic and Zeeman effects with an optical excitation power control. A circular polarization degree up to 0.81 is achieved by changing the off-resonant excitation power. Strongly polarized photon emission enhanced by a slow light mode shows great potential to attain controllable spin-resolved photon sources for integrated optical quantum networks on chip.Comment: 7 pages,5 figure

    Assessing the alignment accuracy of state-of-the-art deterministic fabrication methods for single quantum dot devices

    Full text link
    The realization of efficient quantum light sources relies on the integration of self-assembled quantum dots (QDs) into photonic nanostructures with high spatial positioning accuracy. In this work, we present a comprehensive investigation of the QD position accuracy, obtained using two marker-based QD positioning techniques, photoluminescence (PL) and cathodoluminescence (CL) imaging, as well as using a marker-free in-situ electron beam lithography (in-situ EBL) technique. We employ four PL imaging configurations with three different image processing approaches and compare them with CL imaging. We fabricate circular mesa structures based on the obtained QD coordinates from both PL and CL image processing to evaluate the final positioning accuracy. This yields final position offset of the QD relative to the mesa center of μx\mu_x = (-40±\pm58) nm and μy\mu_y = (-39±\pm85) nm with PL imaging and μx\mu_x = (-39±\pm30) nm and μy\mu_y = (25±\pm77) nm with CL imaging, which are comparable to the offset μx\mu_x = (20±\pm40) nm and μy\mu_y = (-14±\pm39) nm obtained using the in-situ EBL method. We discuss the possible causes of the observed offsets, which are significantly larger than the QD localization uncertainty obtained from simply imaging the QD light emission from an unstructured wafer. Our study highlights the influences of the image processing technique and the subsequent fabrication process on the final positioning accuracy for a QD placed inside a photonic nanostructure

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    Wet-Etched Microlens Array for 200 nm Spatial Isolation of Epitaxial Single QDs and 80 nm Broadband Enhancement of Their Quantum Light Extraction

    No full text
    Uniform arrays of three shapes (gauss, hat, and peak) of GaAs microlenses (MLs) by wet-etching are demonstrated, ∼200 nm spatial isolation of epitaxial single QDs embedded (λ: 890–990 nm) and broadband (Δλ∼80 nm) enhancement of their quantum light extraction are obtained, which is also suitable for telecom-band epitaxial QDs. Combined with the bottom distributed Bragg reflector, the hat-shaped ML forms a cavity and achieves the best enhancement: extraction efficiency of 26%, Purcell factor of 2 and single-photon count rate of 7×106 counts per second at the first lens; while the gauss-shaped ML shows a broader band (e.g., longer λ) enhancement. In the MLs, single QDs with featured exciton emissions are observed, whose time correlations prove single-photon emission with multi-photon probability g(2)(0)=0.02; some QDs show both biexciton XX and exciton X emissions and exhibit a perfect cascade feature. This work could pave a step towards a scalable array of QD single-photon sources and the application of QD photon-pair emission for entanglement experiments

    Critical Study Quality Management for the Anti-Seepage System in Macau’s Landfill Area

    No full text
    This paper delves into the Macau landfill’s anti-seepage system project quality management, highlighting its environmental significance. We summarize global research and provide an overview of the project, emphasizing the importance of quality control across phases. We focus on monitoring, evaluation, and inspection methods to ensure quality objectives. Our findings contribute to environmental preservation and sustainability

    Impact of Rain Gauge Quality Control and Interpolation on Streamflow Simulation: An Application to the Warwick Catchment, Australia

    No full text
    Rain gauges are widely used to obtain temporally continuous point rainfall records, which are then interpolated into spatially continuous data to force hydrological models. However, rainfall measurements and interpolation procedure are subject to various uncertainties, which can be reduced by applying quality control and selecting appropriate spatial interpolation approaches. Consequently, the integrated impact of rainfall quality control and interpolation on streamflow simulation has attracted increased attention but not been fully addressed. This study applies a quality control procedure to the hourly rainfall measurements obtained in the Warwick catchment in eastern Australia. The grid-based daily precipitation from the Australian Water Availability Project was used as a reference. The Pearson correlation coefficient between the daily accumulation of gauged rainfall and the reference data was used to eliminate gauges with significant quality issues. The unrealistic outliers were censored based on a comparison between gauged rainfall and the reference. Four interpolation methods, including the inverse distance weighting (IDW), nearest neighbors (NN), linear spline (LN), and ordinary Kriging (OK), were implemented. The four methods were firstly assessed through a cross-validation using the quality-controlled rainfall data. The impacts of the quality control and interpolation on streamflow simulation were then evaluated through a semi-distributed hydrological model. The results showed that the Nash–Sutcliffe model efficiency coefficient (NSE) and Bias of the streamflow simulations were significantly improved after quality control. In the cross-validation, the IDW and OK methods resulted in good interpolation rainfall, while the NN led to the worst result. In terms of the impact on hydrological prediction, the IDW led to the most consistent streamflow predictions with the observations, according to the validation at five streamflow-gauged locations. The OK method performed second best according to streamflow predictions at the five gauges in the calibration period (01/01/2008–31/12/2011) and four gauges during the validation period (01/01/2012–30/06/2014). However, NN produced the worst prediction at the outlet of the catchment in the validation period, indicating a low robustness. While the IDW exhibited the best performance in the study catchment in terms of accuracy, robustness, and efficiency, more general recommendations on the selection of rainfall interpolation methods need to be further explored under different catchment hydrological systems in future studies

    Conversion of Waste Corn Straw to Value-Added Fuel via Hydrothermal Carbonization after Acid Washing

    No full text
    To enhance the hydrothermal carbonization (HTC) process on biomass waste and improve the quality of biomass solid fuel. Corn straw was pretreated with acid washing and subsequently hydrothermally carbonized at 180–270 °C. The solid product obtained (hydrochars) was compared with the solid product produced from untreated hydrothermally carbonized straw. The results show that the acid pretreatment removed 7.9% of the ash from the straw. ICP and XRD analysis show that most of the alkali and alkaline earth metals have been removed. This addresses the defect of high ash content as the HTC temperature increases. The HHV of hydrochars produced by HTC after acid washing can reach 27.7 MJ/kg, which is nearly 10% higher than that of hydrochars prepared without acid washing pretreatment, and nearly 70% higher than that of straw raw materials. Elemental analysis and FTIR analysis show that the acid washing pretreatment changed the content and structure of the biomass components in the straw, resulting in a more complete HTC reaction and higher carbon sequestration. The decrease of H/C and O/C deepened the degree of coal-like transformation of hydrochars, with the lowest approaching the bituminous coal zone. The combustion characteristics of the hydrochars prepared after acid washing were significantly upgraded, the comprehensive combustion index and thermal stability of hydrochars both increased. Therefore, HTC after acid washing pretreatment is beneficial to further improve the high heating value and combustion characteristics of hydrochar
    corecore