15 research outputs found

    Coherence assisted resonance with sub-lifetime-limited linewidth

    Get PDF
    We demonstrate a novel approach to obtain resonance linewidth below that limited by coherence lifetime. Cross correlation between induced intensity modulation of two lasers coupling the target resonance exhibits a narrow spectrum. 1/30 of the lifetime-limited width was achieved in a proof-of-principle experiment where two ground states are the target resonance levels. Attainable linewidth is only limited by laser shot noise in principle. Experimental results agree with an intuitive analytical model and numerical calculations qualitatively. This technique can be easily implemented and should be applicable to many atomic, molecular and solid state spin systems for spectroscopy, metrology and resonance based sensing and imaging.Comment: 5 pages 5 figure

    Two-axis-twisting spin squeezing by multi-pass quantum erasure

    Get PDF
    Many-body entangled states are key elements in quantum information science and quantum metrology. One important problem in establishing a high degree of many-body entanglement using optical techniques is the leakage of the system information via the light that creates such entanglement. We propose an all-optical interference-based approach to erase this information. Unwanted atom-light entanglement can be removed by destructive interference of three or more successive atom-light interactions, with only the desired effective atom-atom interaction left. This quantum erasure protocol allows implementation of Heisenberg-limited spin squeezing using coherent light and a cold or warm atomic ensemble. Calculations show that significant improvement in the squeezing exceeding 10 dB is obtained compared to previous methods, and substantial spin squeezing is attainable even under moderate experimental conditions. Our method enables the efficient creation of many-body entangled states with simple setups, and thus is promising for advancing technologies in quantum metrology and quantum information processing.Comment: 10 pages, 4 figures. We have improved the presentation and added a new section, in which we have generalized the scheme from a three-pass scheme to multi-pass schem

    Charge Measurement of Cosmic Ray Nuclei with the Plastic Scintillator Detector of DAMPE

    Full text link
    One of the main purposes of the DArk Matter Particle Explorer (DAMPE) is to measure the cosmic ray nuclei up to several tens of TeV or beyond, whose origin and propagation remains a hot topic in astrophysics. The Plastic Scintillator Detector (PSD) on top of DAMPE is designed to measure the charges of cosmic ray nuclei from H to Fe and serves as a veto detector for discriminating gamma-rays from charged particles. We propose in this paper a charge reconstruction procedure to optimize the PSD performance in charge measurement. Essentials of our approach, including track finding, alignment of PSD, light attenuation correction, quenching and equalization correction are described detailedly in this paper after a brief description of the structure and operational principle of the PSD. Our results show that the PSD works very well and almost all the elements in cosmic rays from H to Fe are clearly identified in the charge spectrum.Comment: 20 pages, 4 figure

    Minimally invasive valve surgery including patients of combined simultaneous surgery: a retrospective study

    No full text
    Abstract Objective This study investigated the perioperative safety and advantages of performing a minimally invasive valve surgery (MIVS) and conducting a preliminary examination of the combined simultaneous surgery (CSS). Methods A total of 29 patients (16 men and 13 women; mean age, 58.41 ± 13.08 years) who underwent MIVS at our center from July 2021 to March 2022 were selected. Among them, 16 patients underwent aortic valve surgery (AVS), 13 patients underwent mitral valve surgery (MVS), and four patients additionally underwent CSS. Results The MIVS time ranged from 165 to 420 min, with a mean of 230.54 ± 54.61 min; the cardiopulmonary bypass (CPB) time ranged from 54 to 164 min, with a mean of 120.24 ± 25.98 min; the aortic cross-clamp (ACC) time ranged from 36 to 118 min, with a mean of 78.66 ± 21.01 min and an automatic heart resuscitating rate was 89.66%; the mean tracheal intubation time was 6.30 ± 3.87 h, and the median total postoperative drainage was 317.5 (35, 1470) ml. No difference was observed between preoperative and postoperative left ventricular ejection fraction (LVEF) (61.90% ± 6.28% vs. 60.21% ± 5.52%, P = 0.281). The difference in postoperative drainage (419.20 ml ± 377.20 ml vs. 588.75 ml ± 673.63 ml, P = .461), tracheal intubation time (6.66 h ± 4.27 h vs. 4.63 h ± 1.11 h, P = .359), intensive care unit (ICU) stay (3.96 ± 8.62 days vs. 2.00 ± 0.816 days, P = .658), and postoperative hospital stay (9.96 ± 8.45 days vs. 8.25 ± 1.26 days, P = .694) between MIVS and CSS was not significant. Conclusion MIVS in our center may be safe and effective. Additionally, CSS may be a feasible option that could be performed after a thorough preoperative evaluation and multidisciplinary discussion

    Observations of Forbush Decreases of Cosmic-Ray Electrons and Positrons with the Dark Matter Particle Explorer

    No full text
    The Forbush decrease (FD) represents the rapid decrease of the intensities of charged particles accompanied with the coronal mass ejections or high-speed streams from coronal holes. It has been mainly explored with the ground-based neutron monitor network, which indirectly measures the integrated intensities of all species of cosmic rays by counting secondary neutrons produced from interaction between atmospheric atoms and cosmic rays. The space-based experiments can resolve the species of particles but the energy ranges are limited by the relatively small acceptances except for the most abundant particles like protons and helium. Therefore, the FD of cosmic-ray electrons and positrons have just been investigated by the PAMELA experiment in the low-energy range (<5 GeV) with limited statistics. In this paper, we study the FD event that occurred in 2017 September with the electron and positron data recorded by the Dark Matter Particle Explorer. The evolution of the FDs from 2 GeV to 20 GeV with a time resolution of 6 hr are given. We observe two solar energetic particle events in the time profile of the intensity of cosmic rays, the earlier, and weaker, one has not been shown in the neutron monitor data. Furthermore, both the amplitude and recovery time of fluxes of electrons and positrons show clear energy dependence, which is important in probing the disturbances of the interplanetary environment by the coronal mass ejections

    The Giant Radio Array for Neutrino Detection (GRAND) Collaboration -- Contributions to the 38th International Cosmic Ray Conference (ICRC 2023)

    No full text
    International audienceThe Giant Radio Array for Neutrino Detection (GRAND) is an envisioned observatory of ultra-high-energy particles of cosmic origin, with energies in excess of 100 PeV. GRAND uses large surface arrays of autonomous radio-detection units to look for the radio emission from extensive air showers that are triggered by the interaction of ultra-high-energy cosmic rays, gamma rays, and neutrinos in the atmosphere or underground. In particular, for ultra-high-energy neutrinos, the future final phase of GRAND aims to be sensitive enough to discover them in spite of their plausibly tiny flux. Presently, three prototype GRAND radio arrays are in operation: GRANDProto300, in China, GRAND@Auger, in Argentina, and GRAND@Nancay, in France. Their goals are to field-test the design of the radio-detection units, understand the radio background to which they are exposed, and develop tools for diagnostic, data gathering, and data analysis. This list of contributions to the 38th International Cosmic Ray Conference (ICRC 2023) presents an overview of GRAND, in its present and future incarnations, and a look at the first data collected by GRANDProto13, the first phase of GRANDProto300
    corecore