2,561 research outputs found
Spin-phonon coupling in single Mn doped CdTe quantum dot
The spin dynamics of a single Mn atom in a laser driven CdTe quantum dot is
addressed theoretically. Recent experimental
results\cite{Le-Gall_PRL_2009,Goryca_PRL_2009,Le-Gall_PRB_2010}show that it is
possible to induce Mn spin polarization by means of circularly polarized
optical pumping. Pumping is made possible by the faster Mn spin relaxation in
the presence of the exciton. Here we discuss different Mn spin relaxation
mechanisms. First, Mn-phonon coupling, which is enhanced in the presence of the
exciton. Second, phonon-induced hole spin relaxation combined with carrier-Mn
spin flip coupling and photon emission results in Mn spin relaxation. We model
the Mn spin dynamics under the influence of a pumping laser that injects
excitons into the dot, taking into account exciton-Mn exchange and phonon
induced spin relaxation of both Mn and holes. Our simulations account for the
optically induced Mn spin pumping.Comment: 17 pages, 11 figures, submitted to PR
Dynamics of a nanowire superlattice in an ac electric field
With a one-band envelope function theory, we investigate the dynamics of a
finite nanowire superlattice driven by an ac electric field by solving
numerically the time-dependent Schroedinger equation. We find that for an ac
electric field resonant with two energy levels located in two different
minibands, the coherent dynamics in nanowire superlattices is much more complex
as compared to the standard two-level description. Depending on the energy
levels involved in the transitions, the coherent oscillations exhibit different
patterns. A signature of barrier-well inversion phenomenon in nanowire
superlattices is also obtained.Comment: 14 pages, 4 figure
Optoelectronics of Inverted Type-I CdS/CdSe Core/Crown Quantum Ring
Inverted type-I heterostructure core/crown quantum rings (QRs) are
quantum-efficient luminophores, whose spectral characteristics are highly
tunable. Here, we study the optoelectronic properties of type-I core/crown
CdS/CdSe QRs in the zincblende phase - over contrasting lateral size and crown
width. For this we inspect their strain profiles, transition energies,
transition matrix elements, spatial charge densities, electronic bandstructure,
band-mixing probabilities, optical gain spectra, maximum optical gains and
differential optical gains. Our framework uses an effective-mass envelope
function theory based on the 8-band kp method employing the valence
force field model for calculating the atomic strain distributions. The gain
calculations are based on the density-matrix equation and take into
consideration the excitonic effects with intraband scattering. Variations in
the QR lateral size and relative widths of core and crown (ergo the
composition) affect their energy levels, band-mixing probabilities, optical
transition matrix elements, emission wavelengths/intensity, etc. The optical
gain of QRs is also strongly dimension and composition dependent with further
dependency on the injection carrier density causing band-filling effect. They
also affect the maximum and differential gain at varying dimensions and
compositions.Comment: Published in AIP Journal of Applied Physics (11 pages, 7 figures
A Study of Gaussianity in CMB band maps
The detection of non-Gaussianity in the CMB data would rule out a number of
inflationary models. A null detection of non-Gaussianity, instead, would
exclude alternative models for the early universe. Thus, a detection or
non-detection of primordial non-Gaussianity in the CMB data is crucial to
discriminate among inflationary models, and to test alternative scenarios.
However, there are various non-cosmological sources of non-Gaussianity. This
makes important to employ different indicators in order to detect distinct
forms of non-Gaussianity in CMB data. Recently, we proposed two new indicators
to measure deviation from Gaussianity on large angular scales, and used them to
study the Gaussianity of the raw band WMAP maps with and without the KQ75 mask.
Here we extend this work by using these indicators to perform similar analyses
of deviation from Gaussianity of the foreground-reduced Q, V, and W band maps.
We show that there is a significant deviation from Gaussianity in the
considered full-sky maps, which is reduced to a level consistent with
Gaussianity when the KQ75 mask is employed.Comment: 5 pages, 2 PS figures, uses ws-ijmpd.cls ; to be published in the
International Journal of Modern Physics
Electronic structure of silicon-based nanostructures
We have developed an unifying tight-binding Hamiltonian that can account for
the electronic properties of recently proposed Si-based nanostructures, namely,
Si graphene-like sheets and Si nanotubes. We considered the and
models up to first- and second-nearest neighbors, respectively. Our
results show that the Si graphene-like sheets considered here are metals or
zero-gap semiconductors, and that the corresponding Si nanotubes follow the
so-called Hamada's rule [Phys. Rev. Lett. {\bf 68}, 1579 1992]. Comparison to a
recent {\it ab initio} calculation is made.Comment: 12 pages, 6 Figure
Ultrasound-Guided Glenohumeral Joint Injection Using the Posterior Approach
Injection treatment to the glenohumeral joint is often needed to treat shoulder problems such as adhesive capsulitis. This can be done through blind palpation technique and fluoroscopic or musculoskeletal ultrasound guidance. In recent years, ultrasound has been proven to increase the accuracy of needle placement into the glenohumeral joint. Ultrasound is radiation free and offers real-time images in performing needle-guided injection procedures. Glenohumeral joint injection can be done using the anterior rotator interval approach or the posterior approach technique. Both techniques are generally well tolerated by the patients. However, it was shown that the posterior injection technique offers an easier and a more effective approach to the glenohumeral joint with less extravasation rate as compared with the anterior approach. The posterior approach also avoids the potential risk of accidental puncture or injection into the axillary neurovascular structures. A linear transducer of 5–12 MHz is usually used. This technique is often applied to inject corticosteroid for the treatment of frozen shoulder or contrast medium for computed tomography or magnetic resonance shoulder arthrography
Spatial mapping of band bending in semiconductor devices using in-situ quantum sensors
Band bending is a central concept in solid-state physics that arises from
local variations in charge distribution especially near semiconductor
interfaces and surfaces. Its precision measurement is vital in a variety of
contexts from the optimisation of field effect transistors to the engineering
of qubit devices with enhanced stability and coherence. Existing methods are
surface sensitive and are unable to probe band bending at depth from surface or
bulk charges related to crystal defects. Here we propose an in-situ method for
probing band bending in a semiconductor device by imaging an array of
atomic-sized quantum sensing defects to report on the local electric field. We
implement the concept using the nitrogen-vacancy centre in diamond, and map the
electric field at different depths under various surface terminations. We then
fabricate a two-terminal device based on the conductive two-dimensional hole
gas formed at a hydrogen-terminated diamond surface, and observe an unexpected
spatial modulation of the electric field attributed to a complex interplay
between charge injection and photo-ionisation effects. Our method opens the way
to three-dimensional mapping of band bending in diamond and other
semiconductors hosting suitable quantum sensors, combined with simultaneous
imaging of charge transport in complex operating devices.Comment: This is a pre-print of an article published in Nature Electronics.
The final authenticated version is available online at
https://dx.doi.org/10.1038/s41928-018-0130-
- …