126 research outputs found

    Caries lesion remineralization with fluoride toothpastes and chlorhexidine - effects of application timing and toothpaste surfactant

    Get PDF
    INTRODUCTION: Habitual toothbrushing with fluoridated toothpaste followed by rinsing with antibacterial mouthwashes is a method to maintain good oral hygiene and to diminish the occurrence and severity of dental caries and periodontal disease. However, our understanding of how antimicrobial agents in mouthwashes affect fluoride-mediated caries lesion remineralization is still poor. OBJECTIVE: The objectives of this in vitro study were a) to determine the effects of the waiting period of chlorhexidine (CHX) rinsing after fluoride toothpaste use and b) to further determine the effect of the type of toothpaste surfactant [sodium dodecyl sulfate (SDS) or cocamidopropyl betaine (CAPB)] on caries lesion remineralization associated with CHX rinsing. MATERIAL AND METHODS: Caries lesions were formed in bovine enamel specimens and assigned to 10 treatment groups (n=18) based on Vickers surface microhardness (VHN). Lesions were then pH-cycled for 10 days with daily regimen comprised of twice daily toothpaste slurry treatments (1150 ppm fluoride, with SDS or CAPB), followed by CHX solution treatments [0, 15, 30 or 60 minutes following slurry treatment or no CHX treatment (negative control)]. VHN was measured again and the extent of lesion remineralization calculated (∆VHN). RESULTS: ∆VHN with SDS-toothpaste was significantly lower than with CAPB-toothpaste, indicating more remineralization for the CAPB-toothpaste. ∆VHN with 0-minute waiting time was significantly lower than with 30-minute waiting time and with negative control. CONCLUSIONS: The absence of CHX as an adjunct to fluoride toothpastes led to greater remineralization of enamel lesions compared with the immediate use of CHX treatment for both SDS- and CAPB-toothpastes. CAPB-toothpastes indicated significantly greater remineralization than SDS-toothpastes, and can be suggested for patients at high risk of caries. A 30-minute waiting time for CHX treatment is recommended after brushing

    Caries lesion remineralization with fluoride toothpastes and chlorhexidine - effects of application timing and toothpaste surfactant

    Get PDF
    Habitual toothbrushing with fluoridated toothpaste followed by rinsing with antibacterial mouthwashes is a method to maintain good oral hygiene and to diminish the occurrence and severity of dental caries and periodontal disease. However, our understanding of how antimicrobial agents in mouthwashes affect fluoride-mediated caries lesion remineralization is still poor. Objective: The objectives of this in vitro study were a) to determine the effects of the waiting period of chlorhexidine (CHX) rinsing after fluoride toothpaste use and b) to further determine the effect of the type of toothpaste surfactant [sodium dodecyl sulfate (SDS) or cocamidopropyl betaine (CAPB)] on caries lesion remineralization associated with CHX rinsing. Material and Methods: Caries lesions were formed in bovine enamel specimens and assigned to 10 treatment groups (n=18) based on Vickers surface microhardness (VHN). Lesions were then pH-cycled for 10 days with daily regimen comprised of twice daily toothpaste slurry treatments (1150 ppm fluoride, with SDS or CAPB), followed by CHX solution treatments [0, 15, 30 or 60 minutes following slurry treatment or no CHX treatment (negative control)]. VHN was measured again and the extent of lesion remineralization calculated (∆VHN). Results: ∆VHN with SDS-toothpaste was significantly lower than with CAPB-toothpaste, indicating more remineralization for the CAPB-toothpaste. ∆VHN with 0-minute waiting time was significantly lower than with 30-minute waiting time and with negative control. Conclusions: The absence of CHX as an adjunct to fluoride toothpastes led to greater remineralization of enamel lesions compared with the immediate use of CHX treatment for both SDS- and CAPB-toothpastes. CAPB-toothpastes indicated significantly greater remineralization than SDS-toothpastes, and can be suggested for patients at high risk of caries. A 30-minute waiting time for CHX treatment is recommended after brushing

    The Impact of Nicotine and Cigarette Smoke Condensate on Metabolic Activity and Biofilm Formation of Candida albicans on Acrylic Denture Material

    Get PDF
    Purpose Smokers have increased denture stomatitis caused primarily by Candida albicans. The primary aim of this study was to demonstrate the impact of a wide range of nicotine and cigarette smoke condensate (CSC) concentrations on biofilm formation and metabolic activity of C. albicans on acrylic denture material. Materials and Methods C. albicans (ATCC strain 10231) was used. Standardized denture acrylic (PMMA) specimens (total of 135 specimens) were incubated with C. albicans and exposed to nicotine and CSC at different concentrations (0, 0.25, 0.5, 1, 2, 4, 8, 16, and 32 mg/ml) and (0, 0.25, 0.5, 1, 2, and 4 mg/ml), respectively. For each experiment, 3 samples per nicotine and CSC concentration and a total of 45 specimens (27 specimens for the nicotine and 18 specimens for the CSC‐treated samples) were used and were selected randomly for each group. The control group consisted of 0 mg/ml of nicotine or CSC. The viability of C. albicans was measured using spiral plating on blood agar plates. The effect of nicotine and CSC concentrations on planktonic cells was were measured using a microplate reader. Metabolic activity of 24‐hour‐old established C. albicans biofilm exposed to nicotine and CSC for 24 hours in microtiter plates was determined using a 2,3‐bis (2‐methoxy‐4‐nitro‐5‐sulfophenyl)‐2H‐tetrazolium‐carboxanilide (XTT) reduction assay. Results The viability of C. albicans increased concomitant with increasing concentrations of CSC and nicotine, particularly at 0.5 and 2 mg/ml, respectively. Concentrations of CSC and nicotine above this resulted in an inhibitory effect on C. albicans viability. CSC and nicotine at 4 and 16 mg/ml, respectively, increased C. albicans biofilm metabolic activity. Conclusion Nicotine and CSC up to certain concentrations caused increases in biofilm formation, metabolic activity, viability, and planktonic cell absorbance of C. albicans. This in vitro study demonstrates the effectiveness of tobacco on promoting the growth of C. albicans and suggests their potential contributing factor in C. albicans biofilm related infections in smokers

    The influence of delayed light curing on the degree of conversion and polymerization contraction stress in dual-cured resin luting agents

    Get PDF
    The aim of the study was to assess the effect of delayed photo-initiation on the polymerization contraction stress (PCS) and degree of conversion (DC) of a dual-cure resin-luting agent. Thirty-five disk (6 mm × 1 mm) samples (n = 10 each group) of dual cure resin luting agent for PCS assessment were fabricated and polymerized using two illuminated quartz rods. Based on the delay in photo-initiation, 30 disks were divided among six groups [group A-0 min (min) delay, group B-2 min, group C-4 min, group D-6 min, group E-8 min and group F-10 min]. A non-photoinitiated group (group G – chemical cure – n = 5) was included as control. The PCS for all specimens was assessed using a Tensometer. For DC evaluation thirty-five specimens were divided into seven groups with delays in photo-initiation (group H-0 min, group I-2 min, group J-4 min, group K-6 min, group L-8 min and group M-10 min, group N-chemical cure). DC was assessed using attenuated total reflectance spectroscopic technique. Statistical comparison among groups was performed using analysis of variance (α = 0.05). The maximum and minimum PCS and DC values with delayed photo-initiation was observed in group-C (3.34 MPa) & group-F (2.44 MPa); and group-M (0.78 MPa) and group-H (0.55 MPa) respectively. Chemically cured samples showed the least PCS (group-G, 1.94) and DC (group-N, 0.53) values in their respective categories. PCS significantly decreased with delayed photo-initiation. A significant increase in DC was noticed when photo-initiation was delayed in the dual cure resin luting agent

    Assessment of subacromial space and its relationship with scapular upward rotation in college baseball players.

    Get PDF
    CONTEXT: Subacromial impingement is a common injury in baseball players and has been linked to a reduction in the subacromial space. In addition, it has been suggested that decreases in scapular upward rotation will lead to decreases in the subacromial space and ultimately impingement syndrome. OBJECTIVE: The objective of this study was to evaluate the relationship between acromiohumeral distance and scapular upward rotation in healthy college baseball players. DESIGN: Posttest-only study design. SETTING: Controlled laboratory setting. PARTICIPANTS: 24 healthy college baseball players. Intervention: Participants were measured for all dependent variables at preseason. MAIN OUTCOME MEASURES: Acromiohumeral distance at rest and 90° of abduction was measured with a diagnostic ultrasound unit. Scapular upward rotation at rest and 90° of abduction was measured with a digital inclinometer. RESULTS: Dominant-arm acromiohumeral distance at rest and 90° of abduction (P = .694, P = .840) was not significantly different than in the nondominant arm. In addition, there was not a significant correlation between acromiohumeral distance and scapular upward rotation at rest and 90° of abduction for either the dominant or the nondominant arm. CONCLUSIONS: These results indicate that the acromiohumeral distance is not adapting in the dominant arm in healthy throwing athletes. In addition, a relationship was not identified between acromiohumeral distance and scapular upward rotation, which was previously suggested. These results may suggest that changes that are typically seen in an injured population may be occurring due to the injury and are not preexisting. In addition, scapular upward rotation may not be the only contributing factor to acromiohumeral distance

    An investigation into the potential anticaries benefits and contributions to mineral intake of bottled water

    Get PDF
    BACKGROUND: Bottled water has become the most consumed beverage in the United States. The authors aimed to inform the dental profession about the potential anticaries benefits of some bottled waters and to provide information about their possible contributions to fluoride, calcium, magnesium, sodium, and potassium intakes. METHODS: The authors chose a convenience sample by purchasing all different bottled waters from the main supermarkets operating in Indianapolis, Indiana. The authors analyzed the fluoride content using a fluoride ion-specific electrode and metal concentrations using atomic absorption spectroscopy. They used dietary reference intakes to calculate hypothetical intakes of all minerals. RESULTS: The authors identified 92 different bottled waters. Fluoride concentrations were generally low (mean, 0.11 parts per million [ppm]; median, 0.04 ppm). Only 2 waters contained more than 0.7 ppm fluoride (0.95 ppm and 1.22 ppm). Metal concentrations varied considerably among waters. Calcium concentrations ranged from less than 0.1 through 360 ppm (mean, 26.9 ppm; median, 5.2 ppm), which were greater than those of magnesium (range, < 0.01-106 ppm; mean, 7.5 ppm; median, 1.9 ppm), sodium (range, < 0.01-109 ppm; mean, 11.1 ppm; median, 2.9 ppm), and potassium (range, < 0.01-43 ppm; mean, 3.6 ppm; median, 1.2 ppm). Overall, most bottled waters do not contribute to adequate intakes of fluoride, potassium, or sodium or to recommended dietary allowances for calcium and magnesium. Nonetheless, some waters can provide meaningful contributions to fluoride, calcium, and magnesium intake. CONCLUSIONS: The fluoride concentration in 90 of the 92 studied bottled waters is insufficient to contribute to caries prevention. Only a few bottled waters can be considered health-promoting. PRACTICAL IMPLICATIONS: Dental professionals should consider the mineral content of water consumed by their patients during caries risk assessment

    Human Developmental Chondrogenesis as a Basis for Engineering Chondrocytes from Pluripotent Stem Cells

    Get PDF
    Joint injury and osteoarthritis affect millions of people worldwide, but attempts to generate articular cartilage using adult stem/progenitor cells have been unsuccessful. We hypothesized that recapitulation of the human developmental chondrogenic program using pluripotent stem cells (PSCs) may represent a superior approach for cartilage restoration. Using laser-capture microdissection followed by microarray analysis, we first defined a surface phenotype (CD166(low/neg)CD146(low/neg)CD73(+)CD44(low)BMPR1B(+)) distinguishing the earliest cartilage committed cells (prechondrocytes) at 5-6 weeks of development. Functional studies confirmed these cells are chondrocyte progenitors. From 12 weeks, only the superficial layers of articular cartilage were enriched in cells with this progenitor phenotype. Isolation of cells with a similar immunophenotype from differentiating human PSCs revealed a population of CD166(low/neg)BMPR1B(+) putative cartilage-committed progenitors. Taken as a whole, these data define a developmental approach for the generation of highly purified functional human chondrocytes from PSCs that could enable substantial progress in cartilage tissue engineering.Fil: Wu, Ling. University of California at Los Angeles; Estados UnidosFil: Bluguermann, Carolina. Fundación para la Lucha contra las Enfermedades Neurológicas de la Infancia. Laboratorio de Biología del Desarrollo Celular; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. University of California at Los Angeles; Estados UnidosFil: Kyupelyan, Levon. University of California at Los Angeles; Estados UnidosFil: Latour, Brooke. University of California at Los Angeles; Estados UnidosFil: Gonzalez, Stephanie. University of California at Los Angeles; Estados UnidosFil: Shah, Saumya. University of California at Los Angeles; Estados UnidosFil: Galic, Zoran. University of California at Los Angeles; Estados UnidosFil: Ge, Sundi. University of California at Los Angeles; Estados UnidosFil: Zhu, Yuhua. University of California at Los Angeles; Estados UnidosFil: Petrigliano, Frank A.. University of California at Los Angeles; Estados UnidosFil: Nsair, Ali. University of California at Los Angeles; Estados UnidosFil: Miriuka, Santiago Gabriel. Fundación para la Lucha contra las Enfermedades Neurológicas de la Infancia. Laboratorio de Biología del Desarrollo Celular; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Li, Xinmin. University of California at Los Angeles; Estados UnidosFil: Lyons, Karen M.. University of California at Los Angeles; Estados UnidosFil: Crooks, Gay M.. University of California at Los Angeles; Estados UnidosFil: McAllister, David R.. University of California at Los Angeles; Estados UnidosFil: Van Handel, Ben. Novogenix Laboratories; Estados UnidosFil: Adams, John S.. University of California at Los Angeles; Estados UnidosFil: Evseenko, Denis. University of California at Los Angeles; Estados Unido

    The effect of theobromine on the in vitro de- and remineralization of enamel carious lesions

    Get PDF
    Objectives This in vitro study investigated the effect of theobromine on the de- and remineralization of enamel carious lesions under plaque fluid-like conditions. Methods Early carious lesions were created in 272 bovine enamel specimens and assigned to sixteen groups (n = 17) based on Knoop surface microhardness (SMH). Lesions were demineralized again under plaque fluid-like conditions in the presence of fluoride (0.2 or 1 ppm) and theobromine (0; 10; 100 or 200 ppm) at different pH values (5.5 or 7.0) in a factorial design. SMH was determined again and percent SMH recovery (%SMHr) calculated. Three-way ANOVA was used for the fixed effects of fluoride, theobromine and pH levels to compare the differences between each level. Results The three-way interaction was not significant (p = 0.712). The two-way interaction between fluoride and pH was significant (p = 0.030), whereas those between fluoride and theobromine as well as that for pH and theobromine were not (p = 0.478 and p = 0.998, respectively). Theobromine did not affect %SMHr at any of the tested concentrations. There were trends for the higher fluoride concentration and the higher pH resulting in more rehardening with the lesions exposed to 0.2 ppm fluoride at pH 5.5 displaying significantly less rehardening than those exposed to 0.2 ppm fluoride at pH of 7.0 and lesions exposed to 1 ppm fluoride at pH of 5.5. Conclusion Theobromine, when continuously present in a plaque fluid-like medium at various concentrations and at different pH values, does not affect de- or remineralization of enamel carious lesions under the presently studied conditions

    In vitro demineralization prevention by fluoride and silver nanoparticles when applied to sound enamel and enamel caries-like lesions of varying severities

    Get PDF
    Objectives To investigate the effect of fluoride and silver nanoparticles on the prevention of in vitro demineralization of sound enamel and enamel caries-like lesions of varying severities. Methods Caries-like lesions of different severities (1/6/15 days) were created in bovine enamel specimens. One group remained sound. All specimens were demineralized again using a partially saturated acetic acid solution. Mimicking the intra-oral retention of fluoride and silver in vitro, this solution was supplemented with fluoride (0/1/10 ppm) and/or silver nanoparticles (0/10 ppm) in a factorial design. Changes in lesion depth (ΔL) and integrated mineral loss (ΔΔZ) were evaluated by digital transverse microradiography. Data was analyzed using three-way ANOVA. Results Lesion severity significantly affected ΔΔZ and ΔL, after no treatment and after the treatment of fluoride and silver independently (p = 0.012 and p = 0.037, respectively). Fluoride and the fluoride × lesion severity interaction were shown to be significant (p < 0.001) on ΔΔZ and ΔL. Silver nanoparticles significantly affected ΔΔZ (p = 0.041), but not ΔL (p = 0.15). The silver nanoparticles × lesion severity interaction was significant for ΔΔZ and ΔL (p = 0.032 and p = 0.024, respectively). No interaction was observed for ΔΔZ and ΔL between fluoride and silver (p = 0.962 and p = 0.971, respectively) as well as lesion severity and the use of fluoride and silver combined (p = 0.722 and p = 0.158, respectively). Conclusion Fluoride and silver nanoparticles had a significant effect on the prevention of in vitro demineralization of sound enamel and enamel caries-like lesions of varying severities. Clinical significance Fluoride and silver nanoparticles may potentially allow for more tailored caries prevention

    In Flight Calibration of the Magnetospheric Multiscale Mission Fast Plasma Investigation

    Get PDF
    The Fast Plasma Investigation (FPI) on the Magnetospheric Multiscale mission (MMS) combines data from eight spectrometers, each with four deflection states, into a single map of the sky. Any systematic discontinuity, artifact, noise source, etc. present in this map may be incorrectly interpreted as legitimate data and incorrect conclusions reached. For this reason it is desirable to have all spectrometers return the same output for a given input, and for this output to be low in noise sources or other errors. While many missions use statistical analyses of data to calibrate instruments in flight, this process is difficult with FPI for two reasons: 1. Only a small fraction of high resolution data is downloaded to the ground due to bandwidth limitations and 2: The data that is downloaded is, by definition, scientifically interesting and therefore not ideal for calibration. FPI uses a suite of new tools to calibrate in flight. A new method for detection system ground calibration has been developed involving sweeping the detection threshold to fully define the pulse height distribution. This method has now been extended for use in flight as a means to calibrate MCP voltage and threshold (together forming the operating point) of the Dual Electron Spectrometers (DES) and Dual Ion Spectrometers (DIS). A method of comparing higher energy data (which has low fractional voltage error) to lower energy data (which has a higher fractional voltage error) will be used to calibrate the high voltage outputs. Finally, a comparison of pitch angle distributions will be used to find remaining discrepancies among sensors
    corecore