14,545 research outputs found
A survey of airborne radar systems for deployment on a High Altitude Powered Platform (HAPP)
A survey was conducted to find out the system characteristics of commercially available and unclassified military radars suitable for deployment on a stationary platform. A total of ten domestic and eight foreign manufacturers of the radar systems were identified. Questionnaires were sent to manufacturers requesting information concerning the system characteristics: frequency, power used, weight, volume, power radiated, antenna pattern, resolution, display capabilities, pulse repetition frequency, and sensitivity. A literature search was also made to gather the system characteristics information. Results of the survey are documented and comparisons are made among available radar systems
The Radon Monitoring System in Daya Bay Reactor Neutrino Experiment
We developed a highly sensitive, reliable and portable automatic system
(H) to monitor the radon concentration of the underground experimental
halls of the Daya Bay Reactor Neutrino Experiment. H is able to measure
radon concentration with a statistical error less than 10\% in a 1-hour
measurement of dehumidified air (R.H. 5\% at 25C) with radon
concentration as low as 50 Bq/m. This is achieved by using a large radon
progeny collection chamber, semiconductor -particle detector with high
energy resolution, improved electronics and software. The integrated radon
monitoring system is highly customizable to operate in different run modes at
scheduled times and can be controlled remotely to sample radon in ambient air
or in water from the water pools where the antineutrino detectors are being
housed. The radon monitoring system has been running in the three experimental
halls of the Daya Bay Reactor Neutrino Experiment since November 2013
Ordering dynamics of the driven lattice gas model
The evolution of a two-dimensional driven lattice-gas model is studied on an
L_x X L_y lattice. Scaling arguments and extensive numerical simulations are
used to show that starting from random initial configuration the model evolves
via two stages: (a) an early stage in which alternating stripes of particles
and vacancies are formed along the direction y of the driving field, and (b) a
stripe coarsening stage, in which the number of stripes is reduced and their
average width increases. The number of stripes formed at the end of the first
stage is shown to be a function of L_x/L_y^\phi, with \phi ~ 0.2. Thus,
depending on this parameter, the resulting state could be either single or
multi striped. In the second, stripe coarsening stage, the coarsening time is
found to be proportional to L_y, becoming infinitely long in the thermodynamic
limit. This implies that the multi striped state is thermodynamically stable.
The results put previous studies of the model in a more general framework
Viability of competing field theories for the driven lattice gas
It has recently been suggested that the driven lattice gas should be
described by a novel field theory in the limit of infinite drive. We review the
original and the new field theory, invoking several well-documented key
features of the microscopics. Since the new field theory fails to reproduce
these characteristics, we argue that it cannot serve as a viable description of
the driven lattice gas. Recent results, for the critical exponents associated
with this theory, are re-analyzed and shown to be incorrect.Comment: 4 pages, revtex, no figure
Prelaunch absolute radiometric calibration of LANDSAT-4 protoflight Thematic Mapper
Results are summarized and analyzed from several prelaunch tests with a 122 cm integrating sphere used as part of the absolute radiometric calibration experiments for the protoflight TM sensor carried on the LANDSAT-4 satellite. The calibration procedure is presented and the radiometric sensitivity of the TM is assessed. The internal calibrator and dynamic range after calibration are considered. Tables show dynamic range after ground processing, spectral radiance to digital number and digital number to spectral radiance values for TM bands 1, 2, 3, 4, 5, 7 and for channel 4 of band 6
Prelaunch absolute radiometric calibration of the reflective bands on the LANDSAT-4 protoflight Thematic Mapper
The results of the absolute radiometric calibration of the LANDSAT 4 thematic mapper, as determined during pre-launch tests with a 122 cm integrating sphere, are presented. Detailed results for the best calibration of the protoflight TM are given, as well as summaries of other tests performed on the sensor. The dynamic range of the TM is within a few per cent of that required in all bands, except bands 1 and 3. Three detectors failed to pass the minimum SNR specified for their respective bands: band 5, channel 3 (dead), band 2, and channels 2 and 4 (noisy or slow response). Estimates of the absolute calibration accuracy for the TM show that the detectors are typically calibrated to 5% absolute error for the reflective bands; 10% full-scale accuracy was specified. Ten tests performed to transfer the detector absolute calibration to the internal calibrator show a 5% range at full scale in the transfer calibration; however, in two cases band 5 showed a 10% and a 7% difference
- …