110 research outputs found
Positronium beam production and scattering cross-sections.
In this work, the efficiency for the production of a monoenergetic positronium beam via the charge-exchange reaction of a positron beam in a gaseous target has been determined for molecular hydrogen and molecular nitrogen. In the case of molecular nitrogen, it has been found that the energy range over which a useful intensity of collimated positronium may be produced can be extended to 250eV, 100eV higher than previously achieved. This should enable measurements of the total and partial positronium cross-sections at correspondingly higher energies, where target inelastic effects are expected to be significant A recent measurement of the integrated positronium formation cross-section for xenon found a larger yield of positronium atoms compared to the other noble gases. A shoulder was also seen 10eV above the peak and it was suggested that this might be due to the production of positronium in an excited state. These findings have provided an incentive to investigate the collimated positronium production efficiency from xenon, which has been found to be surprisingly low. The quantum state of the beam atoms has also been found to be dominantly ground state. Possible reasons for these findings are discussed Total cross-sections for positronium-gas scattering have been extracted from the measurements of the positronium beam production efficiency for both molecular nitrogen and xenon. These quantities have also been determined directly by measuring the intensity of the positronium beam transmitted through a gas cell via the Beer-Lambert Law. A good consistency is found between the values obtained using this method and those determined indirectly. Recently, measurements have been made of the absolute integrated cross-section for the fragmentation of positronium in collision with helium atoms, along with the longitudinal energy distributions of the residual positrons in the energy range -Ep/=13-33eV. Measurements of the latter indicate a peak close to half the residual positronium energy, suggesting that they continue to move in a correlated fashion with the emitted electrons. In the present work, these results have been confirmed using a different method, which enables the energy range of investigation to be extended both to higher and lower values. Preliminary results have also been obtained at Epx=60eV for the ejected positrons and for the ejected electrons at Ep/= 33eV
The GstLAL template bank for spinning compact binary mergers in the second observation run of Advanced LIGO and Virgo
We describe the methods used to construct the aligned-spin template bank of
gravitational waveforms used by the GstLAL-based inspiral pipeline to analyze
data from the second observing run of Advanced LIGO and Virgo. The bank expands
upon the parameter space covered during the first observing run, including
coverage for merging compact binary systems with total mass between 2
and 400 and mass ratios between 1 and
97.989. Thus the systems targeted include merging neutron star-neutron star
systems, neutron star-black hole binaries, and black hole-black hole binaries
expanding into the intermediate-mass range. Component masses less than 2
have allowed (anti-)aligned spins between while
component masses greater than 2 have allowed
(anti-)aligned between . The bank placement technique combines a
stochastic method with a new grid-bank method to better isolate noisy
templates, resulting in a total of 677,000 templates.Comment: 9 pages, 13 figure
Genome-wide meta-analysis of myopia and hyperopia provides evidence for replication of 11 loci
Refractive error (RE) is a complex, multifactorial disorder characterized by a mismatch between the optical power of the eye and its axial length that causes object images to be focused off the retina. The two major subtypes of RE are myopia (nearsightedness) and hyperopia (farsightedness), which represent opposite ends of the distribution of the quantitative measure of spherical refraction. We performed a fixed effects meta-analysis of genome-wide association results of myopia and hyperopia from 9 studies of European-derived populations: AREDS, KORA, FES, OGP-Talana, MESA, RSI, RSII, RSIII and ERF. One genome-wide significant region was observed for myopia, corresponding to a previously identified myopia locus on 8q12 (p = 1.25610-8), which has been reported by Kiefer et al. as significantly associated with myopia age at onset and Verhoeven et al. as significantly associated to mean spherical-equivalent (MSE) refractive error. We observed two genomewide significant association
ATP synthase: from single molecule to human bioenergetics
ATP synthase (FoF1) consists of an ATP-driven motor (F1) and a H+-driven motor (Fo), which rotate in opposite directions. FoF1 reconstituted into a lipid membrane is capable of ATP synthesis driven by H+ flux. As the basic structures of F1 (α3β3γδε) and Fo (ab2c10) are ubiquitous, stable thermophilic FoF1 (TFoF1) has been used to elucidate molecular mechanisms, while human F1Fo (HF1Fo) has been used to study biomedical significance. Among F1s, only thermophilic F1 (TF1) can be analyzed simultaneously by reconstitution, crystallography, mutagenesis and nanotechnology for torque-driven ATP synthesis using elastic coupling mechanisms. In contrast to the single operon of TFoF1, HFoF1 is encoded by both nuclear DNA with introns and mitochondrial DNA. The regulatory mechanism, tissue specificity and physiopathology of HFoF1 were elucidated by proteomics, RNA interference, cytoplasts and transgenic mice. The ATP synthesized daily by HFoF1 is in the order of tens of kilograms, and is primarily controlled by the brain in response to fluctuations in activity
Meta-analysis of 49 549 individuals imputed with the 1000 Genomes Project reveals an exonic damaging variant in ANGPTL4 determining fasting TG levels
Background So far, more than 170 loci have been associated with circulating lipid levels through genomewide association studies (GWAS). These associations are largely driven by common variants, their function is often not known, and many are likely to be markers for the causal variants. In this study we aimed to identify more new rare and low-frequency functional variants associated with circulating lipid levels. Methods We used the 1000 Genomes Project as a reference panel for the imputations of GWAS data from ~60 000 individuals in the discovery stage and ~90 000 samples in the replication stage. Results Our study resu
A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.
Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies
- …