473 research outputs found

    Short term outcomes of topiramate monotherapy as a first-line treatment in newly diagnosed West syndrome

    Get PDF
    PurposeTo investigate the efficacy of topiramate monotherapy in West syndrome prospectively.MethodsThe study population included 28 patients (15 male and 13 female children aged 2 to 18 months) diagnosed with West syndrome. After a 2-week baseline period for documentation of the frequency of spasms, topiramate was initiated at 2 mg/kg/day. The dose was increased by 2 mg/kg every week to a maximum of 12 mg/kg/day. Clinical assessment was based on the parents' report and a neurological examination every 2 weeks for the first 2 months of treatment. The baseline electroencephalograms (EEGs) were compared with the post-treatment EEGs at 2 weeks and 1 month.ResultsWest syndrome was considered to be cryptogenic in 7 of the 28 patients and symptomatic in 21 patients. After treatment, 11 patients (39%) became spasm-free, 6 (21%) had more than 50% spasmsreduction, 3 (11%) showed less than 50% reduction, and 8 (29%) did not respond. The effective daily dose for achieving more than 50% reduction in spasm frequency, including becoming spasm-free, was found to be 5.8±1.1 mg/kg/day. Nine patients (32%) showed complete disappearance of spasms and hypsarrhythmia, and 11 (39%) showed improved EEG results. Despite adverse events (4 instances of irritability, 3 of drowsiness, and 1 of decreased feeding), no patients discontinued the medication.ConclusionTopiramate monotherapy seems to be effective and well tolerated as a first line therapy for West syndrome and is not associated with serious adverse effects

    Characterizations of realized metal-insulator-silicon-insulator-metal waveguides and nanochannel fabrication via insulator removal

    Get PDF
    We investigate experimentally metal-insulator-silicon-insulator-metal (MISIM) waveguides that are fabricated by using fully standard CMOS technology. They are hybrid plasmonic waveguides, and they have a feature that their insulator is replaceable with functional material. We explain a fabrication process for them and discuss fabrication results based on 8-inch silicon-on-insulator wafers. We measured the propagation characteristics of the MISIM waveguides that were actually fabricated to be connected to Si photonic waveguides through symmetric and asymmetric couplers. When incident light from an optical source has transverse electric (TE) polarization and its wavelength is 1318 or 1554 nm, their propagation losses are between 0.2 and 0.3 dB/mu m. Excess losses due to the symmetric couplers are around 0.5 dB, which are smaller than those due to the asymmetric couplers. Additional measurement results indicate that the MISIM waveguide supports a TE-polarized hybrid plasmonic mode. Finally, we explain a process of removing the insulator without affecting the remaining MISIM structure to fabricate similar to 30-nm-wide nanochannels which may be filled with functional material.open8

    GaAs droplet quantum dots with nanometer-thin capping layer for plasmonic applications

    Full text link
    We report on the growth and optical characterisation of droplet GaAs quantum dots with extremely-thin (11 nm) capping layers. To achieve such result, an internal thermal heating step is introduced during the growth and its role in the morphological properties of the quantum dots obtained is investigated via scanning electron and atomic force microscopy. Photoluminescence measurements at cryogenic temperatures show optically stable, sharp and bright emission from single quantum dots, at near-infrared wavelengths. Given the quality of their optical properties and the proximity to the surface, such emitters are ideal candidates for the investigation of near field effects, like the coupling to plasmonic modes, in order to strongly control the directionality of the emission and/or the spontaneous emission rate, crucial parameters for quantum photonic applications.Comment: 1 pages, 3 figure

    Variable formation control of multiple robots via VRc and formation switching to accommodate large heading changes by leader robot

    Get PDF
    This article describes a novel multi-robot formation control based on a switching technique that allows follower robots to maintain formation when the leader robot’s direction changes rapidly or unexpectedly. The formation pattern is determined using Virtual Robot’s Center of the multi-robot formation. To avoid collision, the formation of robots reformed in optimal size by estimating the distance between the robot and an obstacle in real time. When the leader robot suddenly changes its direction, waypoints of follower robots are switched and the formation is quickly reconstructed. This prevents follower robots from colliding with each other and reduces their radius of movement and allows them to follow the leader robot at higher speed. The proposed method which is inherently a flexible control of multi-robot formation guarantees collision avoidance and prevents sudden changes in waypoints of the system by gradually changing its size. The validity of the proposed method is demonstrated via simulation and experimental results. © The Author(s) 2019.1

    ZnO Nanorod Biosensor for Highly Sensitive Detection of Specific Protein Binding

    Get PDF
    We report on the fabrication of electrical biosensors based on functionalized ZnO nanorod surfaces with biotin for highly sensitive detection of biological molecules. Due to the clean interface and easy surface modification, the ZnO nanorod sensors can easily detect streptavidin binding down to a concentration of 25 nM, which is more sensitive than previously reported one-dimensional (1D) nanostructure electrical biosensors. In addition, the unique device structure with a micrometer-scale hole at the center of the ZnO nanorod's conducting channel reduces the leakage current from the aqueous solution, hence enhancing device sensitivity. Moreover, ZnO nanorod field-effect-transistor (FET) sensors may open up opportunities to create many other oxide nanorod electrical sensors for highly sensitive and selective real-time detection of a wide variety of biomolecules.The authors thank Prof. Hee Cheul Choi at POSTECH for helpful discussion. This work was supported by the Korea Research Foundation Grant (KRF-2003-041-C00132)

    Stent insertion and balloon angioplasty for portal vein stenosis after liver transplantation: long-term follow-up results

    Get PDF
    PURPOSEIt is not easy to determine whether balloon angioplasty or stenting should be performed in patients with portal vein stenosis after liver transplantation. We aimed to propose appropriate indication by evaluating long-term outcomes of balloon angioplasty and stent insertion in adult liver transplant patients.METHODSWe retrospectively reviewed 31 patients with portal vein stenosis among 1369 patients who underwent adult liver transplantation from January 2001 to December 2015. When stenosis was confirmed by venography, angioplasty was performed first. When there was no flow improvement or pressure gradient was not decreased after angioplasty, stent insertion was performed. We also performed primary stent insertion without angioplasty for diffuse stenosis, kinking, external compression, and near occlusion of portal vein in venography. We assessed patency in patients who underwent percutaneous transluminal angioplasty and stent insertion through regular outpatient follow-up and evaluated technical and clinical success and long-term results.RESULTSTechnical success was 85% and 100% in balloon angioplasty and stent insertion, respectively. Clinical success was achieved in 78% of balloon angioplasties and in 100% of stent insertions. At 1, 5, and 10 years after balloon angioplasty, patency rates were 87%, 82%, and 68% respectively, and the rates of stent patency were all 100%. Portal vein size measured during the operation of patients with and without recurrence were 19±4.2 mm and 19±3.0 mm (P = 0.956), respectively. The balloon size of patients with and without recurrence were 11±1.95 mm and 14±1.66 mm, respectively (P = 0.013), when balloon angioplasty was performed after stenosis diagnosis.CONCLUSIONStent insertion can be considered when fibrotic changes are expected due to repeated inflammation and when the balloon size to be used is small. Balloon angioplasty seems less risky for anastomotic ruptures in portal vein stenosis in the early post liver transplantation period

    Fabrication and electrical characteristics of high-performance ZnO nanorod field-effect transistors

    Get PDF
    We report on fabrication and electrical characteristics of high-mobility field-effect transistors (FETs) using ZnO nanorods. For FET fabrications, single-crystal ZnO nanorods were prepared using catalyst-free metalorganic vapor phase epitaxy. Although typical ZnO nanorod FETs exhibited good electrical characteristics, with a transconductance of similar to140 nS and a mobility of 75 cm(2)/V s, the device characteristics were significantly improved by coating a polyimide thin layer on the nanorod surface, exhibiting a large turn-ON/OFF ratio of 10(4)-10(5), a high transconductance of 1.9 muS, and high electron mobility above 1000 cm(2)/V s. The role of the polymer coating in the enhancement of the devices is also discussed. (C) 2004 American Institute of Physics
    corecore