Drag of suction cup tags on swimming animals : modeling and measurement
© The Author(s), 2013. This article is distributed under the terms of the Creative Commons Attribution License. The definitive version was published in Marine Mammal Science 30 (2014): 726â746, doi:10.1111/mms.12083.Bio-logging tags are widely used to study the behavior and movements of marine mammals with the tacit assumption of little impact to the animal. However, tags on fast-swimming animals generate substantial hydrodynamic forces potentially affecting behavior and energetics adversely, or promoting early removal of the tag. In this work, hydrodynamic loading of three novel tag housing designs are compared over a range of swimming speeds using computational fluid dynamics (CFD). Results from CFD simulation were verified using tag models in a water flume with close agreement. Drag forces were reduced by minimizing geometric disruptions to the flow around the housing, while lift forces were reduced by minimizing the frontal cross-sectional area of the housing and holding the tag close to the attachment surface. Hydrodynamic tag design resulted in an experimentally measured 60% drag force reduction in 5.6 m/s flow. For all housing designs, off-axis flow increased the magnitude of the force on the tag. Experimental work with a common dolphin (Delphinus delphis) cadaver indicates that the suction cups used to attach the types of tags described here provide sufficient attachment force to resist failure to predicted forces at swimming speeds of up to 10 m/s.This work was supported by NOPP with NSF funds through ONR Grant N00014-11-1-
0113. MJ was supported by NOPP and
the MASTS pooling initiative (The Marine Alliance for Science and Technology for Scotland)
Drag of suction cup tags on swimming animals : modeling and measurement
This work was supported by NOPP with NSF funds through ONR Grant N00014-11-1-0113. MJ was supported by NOPP and the MASTS pooling initiative (The Marine Alliance for Science and Technology for Scotland). MASTS is funded by the Scottish Funding Council (grant reference HR09011) and contributing institutions.Bio-logging tags are widely used to study the behavior and movements of marine mammals with the tacit assumption of little impact to the animal. However, tags on fast-swimming animals generate substantial hydrodynamic forces potentially affecting behavior and energetics adversely, or promoting early removal of the tag. In this work, hydrodynamic loading of three novel tag housing designs are compared over a range of swimming speeds using computational fluid dynamics (CFD). Results from CFD simulation were verified using tag models in a water flume with close agreement. Drag forces were reduced by minimizing geometric disruptions to the flow around the housing, while lift forces were reduced by minimizing the frontal cross-sectional area of the housing and holding the tag close to the attachment surface. Hydrodynamic tag design resulted in an experimentally measured 60% drag force reduction in 5.6 m/s flow. For all housing designs, off-axis flow increased the magnitude of the force on the tag. Experimental work with a common dolphin (Delphinus delphis) cadaver indicates that the suction cups used to attach the types of tags described here provide sufficient attachment force to resist failure to predicted forces at swimming speeds of up to 10 m/s.Publisher PDFPeer reviewe
Computational fluid dynamics of flow regime and hydrodynamic forces generated by a gliding North Atlantic right whale (Eubalaena glacialis)
Accurate estimates of drag on marine animals are required to investigate the locomotive cost, propulsive efficiency, and the impacts of entanglement if the animal is carrying fishing gear. In this study, we performed computational fluid dynamics analysis of a 10âm (length over all) right whale to obtain baseline measurements of drag on the animal. Swimming speeds covering known right whale speed range (0.125âm/s to 8âm/s) were tested. We found a weak dependence between drag coefficient and Reynolds number. At a swimming speed of 2âm/s, we analyzed the boundary layer thicknesses, the flow regimes, and drag components. We found the thickest boundary layer at the lateral sides of the peduncle, whereas the boundary layer thickness over the outer part of the flukes was less than 1.7âcm. Laminar flow occurred over the anterior ~0.6 LoA and turbulent flow from ~0.8 LoA to the fluke notch. On the surfaces of the flukes outside of the body wake region, flow was laminar. Our most significant finding is that the drag coefficient (0.0071â0.0059) of a right whale for swimming speeds ranging from 0.25âm/s to 2âm/s is approximately twice that of many previous estimates for cetaceans
Central venous catheter integrity during mechanical power injection of iodinated contrast medium
PURPOSE: To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. MATERIALS AND METHODS: Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. RESULTS: Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. CONCLUSION: Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig
The probability and severity of decompression sickness.
Decompression sickness (DCS), which is caused by inert gas bubbles in tissues, is an injury of concern for scuba divers, compressed air workers, astronauts, and aviators. Case reports for 3322 air and N2-O2 dives, resulting in 190 DCS events, were retrospectively analyzed and the outcomes were scored as (1) serious neurological, (2) cardiopulmonary, (3) mild neurological, (4) pain, (5) lymphatic or skin, and (6) constitutional or nonspecific manifestations. Following standard U.S. Navy medical definitions, the data were grouped into mild-Type I (manifestations 4-6)-and serious-Type II (manifestations 1-3). Additionally, we considered an alternative grouping of mild-Type A (manifestations 3-6)-and serious-Type B (manifestations 1 and 2). The current U.S. Navy guidance allows for a 2% probability of mild DCS and a 0.1% probability of serious DCS. We developed a hierarchical trinomial (3-state) probabilistic DCS model that simultaneously predicts the probability of mild and serious DCS given a dive exposure. Both the Type I/II and Type A/B discriminations of mild and serious DCS resulted in a highly significant (p << 0.01) improvement in trinomial model fit over the binomial (2-state) model. With the Type I/II definition, we found that the predicted probability of 'mild' DCS resulted in a longer allowable bottom time for the same 2% limit. However, for the 0.1% serious DCS limit, we found a vastly decreased allowable bottom dive time for all dive depths. If the Type A/B scoring was assigned to outcome severity, the no decompression limits (NDL) for air dives were still controlled by the acceptable serious DCS risk limit rather than the acceptable mild DCS risk limit. However, in this case, longer NDL limits were allowed than with the Type I/II scoring. The trinomial model mild and serious probabilities agree reasonably well with the current air NDL only with the Type A/B scoring and when 0.2% risk of serious DCS is allowed
Modifying peripheral IV catheters with side holes and side slits results in favorable changes in fluid dynamic properties during the injection of iodinated contrast material
OBJECTIVE: The purpose of this study was to compare a standard peripheral end-hole angiocatheter with those modified with side holes or side slits using experimental optical techniques to qualitatively compare the contrast material exit jets and using numeric techniques to provide flow visualization and quantitative comparisons. MATERIALS AND METHODS: A Schlieren imaging system was used to visualize the angiocatheter exit jet fluid dynamics at two different flow rates. Catheters were modified by drilling through-and-through side holes or by cutting slits into the catheters. A commercial computational fluid dynamics package was used to calculate numeric results for various vessel diameters and catheter orientations. RESULTS: Experimental images showed that modifying standard peripheral IV angiocatheters with side holes or side slits qualitatively changed the overall flow field and caused the exiting jet to become less well defined. Numeric calculations showed that the addition of side holes or slits resulted in a 9-30% reduction of the velocity of contrast material exiting the end hole of the angiocatheter. With the catheter tip directed obliquely to the wall, the maximum wall shear stress was always highest for the unmodified catheter and was always lowest for the four-side-slit catheter. CONCLUSION: Modified angiocatheters may have the potential to reduce extravasation events in patients by reducing vessel wall shear stress
Trinomial cumulative density function for the serious DCS cases (grey, solid curve) and mild DCS cases (black, solid curve).
<p>The cumulative density function for predicted mild and serious DCS fall on the same curve (black, dashed curve).</p