232 research outputs found

    The GUINEVERE Project for Accelerator Driven System Physics

    No full text
    paper 9414International audienceThe GUINEVERE project is part of the EUROTRANS Integrated Project of the 6th EURATOM Framework Programme. It is mainly devoted to ADS on-line reactivity monitoring validation, sub-criticality determination and operational procedures (loading, start-up, shut-down, ...) as a follow-up of the MUSE experiments. The project consists in coupling a fast lead core, set-up in the VENUS reactor at SCK*CEN Mol (B), with a GENEPI neutron source under construction by CNRS. To accommodate the accelerator in a vertical coupling configuration, the VENUS building is being heightened. The fast core will be loaded with enriched Uranium and will be moderated and reflected with solid lead (zero power experiment). For the purpose of the experimental programme, the neutron source has to be operated not only in pulsed mode but also in continuous mode to investigate the current-to-flux reactivity indicator in representative conditions of a powerful ADS. In this latter mode it is also required to make short beam interruptions to have access to the neutron population decrease as a function of time: from this spectrum it will be possible to apply different analysis techniques such as "prompt decay" fitting techniques and "source jerk" techniques. Beam interruptions will be repeated at a programmable frequency to improve time spectra statistics. Different sub-criticality levels (keff=0.99, 0.97, 0.95, ...) will be investigated in order to obtain a full set of data points for the final overall validation of the methodology. This paper describes the status of the experimental facility assembling, and the foreseen experimental programme to be started

    The GUINEVERE project at the VENUS facility

    No full text
    Proc. on CD Rom log315International audienceThe GUINEVERE project is an international project in the framework of IP-EUROTRANS, the FP6 program which aims at addressing the main issues for ADS development in the framework of partitioning and transmutation for nuclear waste volume and radiotoxicity reduction. The GUINEVERE project is carried out in the context of domain 2 of IP-EUROTRANS, ECATS, devoted to specific experiments for the coupling of an accelerator, a target and a subcritical core. These experiments should provide an answer to the questions of online reactivity monitoring, sub-criticality determination and operational procedures (loading, start-up, shutdown, …) in an ADS by 2009-2010. The project has the objective to couple a fast lead core, within the VENUS building operated by the SCK•CEN, with a neutron generator able to work in three different modes: pulsed, continuous and continuous with beam interruptions at the millisecond scale. In order to achieve this goal, the VENUS facility has to be adapted and a modified GENEPI-3C accelerator has to be designed and constructed. The paper describes the main modifications to the reactor core and facility and to the accelerator, which will be executed during the years 2008 and 2009, and the experimental programme which will start in 2009

    Guidance to 2018 good practice: ARIA digitally-enabled, integrated, person-centred care for rhinitis and asthma

    Get PDF
    Aims: Mobile Airways Sentinel NetworK (MASK) belongs to the Fondation Partenariale MACVIA-LR of Montpellier, France and aims to provide an active and healthy life to rhinitis sufferers and to those with asthma multimorbidity across the life cycle, whatever their gender or socio-economic status, in order to reduce health and social inequities incurred by the disease and to improve the digital transformation of health and care. The ultimate goal is to change the management strategy in chronic diseases. Methods: MASK implements ICT technologies for individualized and predictive medicine to develop novel care pathways by a multi-disciplinary group centred around the patients. Stakeholders: Include patients, health care professionals (pharmacists and physicians), authorities, patient's associations, private and public sectors. Results: MASK is deployed in 23 countries and 17 languages. 26,000 users have registered. EU grants (2018): MASK is participating in EU projects (POLLAR: impact of air POLLution in Asthma and Rhinitis, EIT Health, DigitalHealthEurope, Euriphi and Vigour). Lessons learnt: (i) Adherence to treatment is the major problem of allergic disease, (ii) Self-management strategies should be considerably expanded (behavioural), (iii) Change management is essential in allergic diseases, (iv) Education strategies should be reconsidered using a patient-centred approach and (v) Lessons learnt for allergic diseases can be expanded to chronic diseases

    Development of a novel small antibody that retains specificity for tumor targeting

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>For the targeted therapy of solid tumor mediated by monoclonal antibody (mAb), there have different models of rebuilding small antibodies originated from native ones. Almost all natural antibody molecules have the similar structure and conformation, but those rebuilt small antibodies cannot completely keep the original traits of parental antibodies, especially the reduced specificity, which gravely influences the efficacy of small antibodies.</p> <p>Methods</p> <p>In this study, authors developed a novel mimetic in the form of V<sub>H</sub>FR1<sub>C-10</sub>-V<sub>H</sub>CDR1-V<sub>H</sub>FR2-V<sub>L</sub>CDR3-V<sub>L</sub>FR4<sub>N-10</sub>for a parental mAb induced with human breast cancer, and the mimetic moiety was conjugated to the C-terminal of toxicin colicin Ia. The novel fusion peptide, named protomimecin (PMN), was administered to MCF-7 breast cancer cells to demonstrate its killing competency <it>in vitro </it>and <it>in vivo</it>.</p> <p>Results</p> <p>Compared with original antibody-colicin Ia (Fab-Ia) and single-chain antibody-colicin Ia (Sc-Ia) fusion proteins, PMN retained the targeting specificity of parental antibody and could specifically kill MCF-7 cells <it>in vitro</it>. By injecting intraperitoneally into BALB/c athymic mice bearing MCF-7 tumors, with reduced affinity, PMN significantly suppressed the growth of tumors compared with control mice treated by toxicin protein, Fab-Ia protein, Sc-Ia protein or by PBS (<it>p </it>< 0.05).</p> <p>Conclusion</p> <p>This novel mimetic antibody retained original specificity of parental antibody, and could effectively guide killer moiety to suppress the growth of breast cancer by targeted cell death.</p

    Allergen immunotherapy in MASK-air users in real-life: Results of a Bayesian mixed-effects model

    Full text link
    Background Evidence regarding the effectiveness of allergen immunotherapy (AIT) on allergic rhinitis has been provided mostly by randomised controlled trials, with little data from real-life studies. Objective To compare the reported control of allergic rhinitis symptoms in three groups of users of the MASK-air(R) app: those receiving sublingual AIT (SLIT), those receiving subcutaneous AIT (SCIT), and those receiving no AIT. Methods We assessed the MASK-air(R) data of European users with self-reported grass pollen allergy, comparing the data reported by patients receiving SLIT, SCIT and no AIT. Outcome variables included the daily impact of allergy symptoms globally and on work (measured by visual analogue scales-VASs), and a combined symptom-medication score (CSMS). We applied Bayesian mixed-effects models, with clustering by patient, country and pollen season. Results We analysed a total of 42,756 days from 1,093 grass allergy patients, including 18,479 days of users under AIT. Compared to no AIT, SCIT was associated with similar VAS levels and CSMS. Compared to no AIT, SLIT-tablet was associated with lower values of VAS global allergy symptoms (average difference = 7.5 units out of 100; 95% credible interval [95%CrI] = -12.1;-2.8), lower VAS Work (average difference = 5.0; 95%CrI = -8.5;-1.5), and a lower CSMS (average difference = 3.7; 95%CrI = -9.3;2.2). When compared to SCIT, SLIT-tablet was associated with lower VAS global allergy symptoms (average difference = 10.2; 95%CrI = -17.2;-2.8), lower VAS Work (average difference = 7.8; 95%CrI = -15.1;0.2), and a lower CSMS (average difference = 9.3; 95%CrI = -18.5;0.2). Conclusion In patients with grass pollen allergy, SLIT-tablet, when compared to no AIT and to SCIT, is associated with lower reported symptom severity. Future longitudinal studies following internationally-harmonised standards for performing and reporting real-world data in AIT are needed to better understand its 'real-world' effectiveness

    The Acceleration and Storage of Radioactive Ions for a Beta-Beam Facility

    Full text link
    The term beta-beam has been coined for the production of a pure beam of electron neutrinos or their antiparticles through the decay of radioactive ions circulating in a storage ring. This concept requires radioactive ions to be accelerated to as high Lorentz gamma as 150. The neutrino source itself consists of a storage ring for this energy range, with long straight sections in line with the experiment(s). Such a decay ring does not exist at CERN today, nor does a high-intensity proton source for the production of the radioactive ions. Nevertheless, the existing CERN accelerator infrastructure could be used as this would still represent an important saving for a beta-beam facility.Comment: beta-beam working group website at http://cern.ch/beta-bea

    Work productivity in rhinitis using cell phones:The MASK pilot study

    Get PDF
    Allergic rhinitis often impairs social life and performance. The aim of this cross-sectional study was to use cell phone data to assess the impact on work productivity of uncontrolled rhinitis assessed by visual analogue scale (VAS). A mobile phone app (Allergy Diary, Google Play Store and Apple App Store) collects data from daily visual analogue scales (VAS) for overall allergic symptoms (VAS-global measured), nasal (VAS-nasal), ocular (VAS-ocular) and asthma symptoms (VAS-asthma) as well as work (VAS-work). A combined nasal-ocular score is calculated. The Allergy Diary is available in 21 countries. The app includes the Work Productivity and Activity Impairment Allergic Specific Questionnaire (WPAI: AS) in six EU countries. All consecutive users who completed the VAS-work from 1 June to 31 October 2016 were included in the study. A total of 1136 users filled in 5818 days of VAS-work. Symptoms of allergic rhinitis were controlled (VAS-global <20) in approximately 60% of the days. In users with uncontrolled rhinitis, approximately 90% had some work impairment and over 50% had severe work impairment (VAS-work >50). There was a significant correlation between VAS-global calculated and VAS-work (Rho=0.83, P <0.00001, Spearman's rank test). In 144 users, there was a significant correlation between VAS-work and WPAI: AS (Rho=0.53, P <0.0001). This pilot study provides not only proof-of-concept data on the work impairment collected with the app but also data on the app itself, especially the distribution of responses for the VAS. This supports the interpretation that persons with rhinitis report both the presence and the absence of symptom

    Adherence to inhaled corticosteroids and long-acting β2-agonists in asthma:A MASK-air study

    Get PDF
    Introduction Adherence to controller medication is a major problem in asthma management, being difficult to assess and tackle. mHealth apps can be used to assess adherence. We aimed to assess the adherence to inhaled corticosteroids+long-acting β2-agonists (ICS+LABA) in users of the MASK-air® app, comparing the adherence to ICS+formoterol (ICS+F) with that to ICS+other LABA. Materials and methods We analysed complete weeks of MASK-air® data (2015-2022; 27 countries) from patients with self-reported asthma and ICS+LABA use. We compared patients reporting ICS+F versus ICS+other LABA on adherence levels, symptoms and symptom-medication scores. We built regression models to assess whether adherence to ICS+LABA was associated with asthma control or short-acting beta-agonist (SABA) use. Sensitivity analyses were performed considering the weeks with no more than one missing day. Results In 2598 ICS+LABA users, 621 (23.9%) reported 4824 complete weeks and 866 (33.3%) reported weeks with at most one missing day. Higher adherence (use of medication ≥80% of weekly days) was observed for ICS+other LABA (75.1%) when compared to ICS+F (59.3%), despite both groups displaying similar asthma control and work productivity. The ICS+other LABA group was associated with more days of SABA use than the ICS+F group (median=71.4% versus 57.1% days). Each additional weekly day of ICS+F use was associated with a 4.1% less risk in weekly SABA use (95%CI=-6.5;-1.6%;p=0.001). For ICS+other LABA, the percentage was 8.2 (95%CI=-11.6;-5.0%;p<0.001). Conclusions In asthma patients adherent to the MASK-air app, adherence to ICS+LABA was high. ICS+F users reported lower adherence but also a lower SABA use and a similar level of control
    corecore