38 research outputs found
Comparison of two dengue NS1 rapid tests for sensitivity, specificity and relationship to viraemia and antibody responses
<p>Abstract</p> <p>Background</p> <p>Dengue is a major public health problem in tropical and subtropical countries. Rapid and easy diagnosis of dengue can assist patient triage and care-management. The detection of DENV NS1 on rapid lateral flow tests offers a fast route to a presumptive dengue diagnosis but careful evaluations are urgently needed as more and more people use them.</p> <p>Methods</p> <p>The sensitivity and specificity of the Bio-Rad NS1 Ag Strip and SD Dengue Duo (NS1/IgM/IgG) lateral flow rapid tests were evaluated in a panel of plasma samples from 245 Vietnamese patients with RT-PCR confirmed dengue and 47 with other febrile illnesses.</p> <p>Results</p> <p>The NS1 rapid tests had similar diagnostic sensitivities (respectively 61.6% and 62.4%) in confirmed dengue cases but were 100% specific. When IgM/IgG results from the SD Dengue Duo were included in the test interpretation, the sensitivity improved significantly from 62.4% with NS1 alone to 75.5% when NS1 and/or IgM was positive and 83.7% when NS1 and/or IgM and/or IgG was positive. Both NS1 assays were significantly more sensitive for primary than secondary dengue. NS1 positivity was associated with the underlying viraemia as NS1-positive samples had a significantly higher viraemia than NS1-negative samples.</p> <p>Conclusions</p> <p>These data suggest that the NS1 test component of these assays are highly specific and have similar levels of sensitivity. The IgM parameter in the SD Duo test improved overall test sensitivity without compromising specificity. The SD Dengue Duo lateral flow rapid test deserves further prospective evaluation in dengue endemic settings.</p
Diagnostic Accuracy of NS1 ELISA and Lateral Flow Rapid Tests for Dengue Sensitivity, Specificity and Relationship to Viraemia and Antibody Responses
Dengue is a viral infection of humans that is transmitted by mosquitoes. Dengue is a very important public health problem in many developing countries. Recently, new tests to help diagnose patients with dengue have been developed. Evaluating these tests to see how well they perform in different countries and in different health care settings is an important process that helps to guide health care policy on whether these assays are likely to be useful in making a diagnosis, and if so, when best to use them. Our hospital-based results, using two different types of NS1 tests for diagnosing dengue, indicates that these tests are most sensitive when used during the first 3 days of illness and are most likely to be positive if the patient has primary dengue. Our results also show that a positive NS1 test result is a reflection of the amount of virus in the blood, so that patients with high amounts of virus in the blood are more likely to be NS1 positive. Collectively, the results indicate these NS1 tests deserve inclusion in the diagnostic approach to dengue
Comparison of the diagnostic accuracy of commercial NS1-based diagnostic tests for early dengue infection
<p>Abstract</p> <p>Background</p> <p>We compared the diagnostic accuracy and reproducibility of commercially available NS1-based dengue tests and explored factors influencing their sensitivities.</p> <p>Methods</p> <p>Paired analysis of 310 samples previously characterized as positive (n = 218) and negative (n = 92) for viral isolation and/or RT-PCR and/or IgM seroconversion. Masked samples were tested by two observers with Platelia™ Dengue NS1 Ag, second generation Pan-E™ Dengue Early ELISA, SD Dengue NS1 Ag ELISA, Dengue NS1 Ag STRIP™, and SD BIOLINE™ Dengue Duo (NS1/IgM/IgG).</p> <p>Results</p> <p>SD BIOLINE™ NS1/IgM/IgG had the highest sensitivity (80.7% 95%CI 75-85.7) with likelihood ratios of 7.4 (95%CI 4.1-13.8) and 0.21 (95%CI 0.16-0.28). The ELISA-format tests showed comparable sensitivities; all below 75%. STRIP™ and SD NS1 had even lower sensitivities (<65%). The sensitivities significantly decreased in samples taken after 3 days of fever onset, in secondary infections, viral serotypes 2 and 4, and severe dengue. Adding IgM or IgG to SD NS1 increased its sensitivity in all these situations.</p> <p>Conclusions</p> <p>The simultaneous detection of NS1/IgM/IgG would be potentially useful for dengue diagnosis in both endemic and non endemic areas. A negative result does not rule out dengue. Further studies are required to assess the performance and impact of early laboratory diagnosis of dengue in the routine clinical setting.</p
Comparison of Three Commercially Available Dengue NS1 Antigen Capture Assays for Acute Diagnosis of Dengue in Brazil
Dengue is the one of the most prevalent arthropod-borne viral diseases in tropical regions of the world. Manifestations may vary from asymptomatic to potentially fatal complications. Laboratorial diagnosis is essential to diagnose dengue and differentiate it from other diseases. Dengue virus non-structural protein 1 (NS1) may be used as a marker of acute dengue virus infection. Our results, based in the comparison of three NS1 antigen capture assays available, have shown that this approach is reliable for the early diagnosis of dengue infections, especially in the first four days after the onset of the symptoms. A lower sensitivity was observed in DENV-3 cases. Serum positive by virus isolation were more often detected than those positive by RT-PCR by all three assays. Only the Platelia™ NS1 test showed a higher sensitivity in confirming primary infections than secondary ones. In conclusion, NS1 antigen capture commercial kits are useful for diagnosis of acute primary and secondary dengue infections and, in endemic countries where secondary infections are expected to occur, may be used in combination with MAC-ELISA to increase the overall sensitivity of both tests
Clinical and Virological Features of Dengue in Vietnamese Infants
Dengue is a major public health problem in tropical and subtropical countries, including Vietnam. Dengue cases occur in children and young adults; however, severe dengue also occurs in infants less than 1 year of age. Prompt recognition of dengue is important for appropriate case management, particularly in infants in whom febrile illness from other causes is common. We describe the clinical picture, virological and immunological characteristics of infants with dengue admitted to three hospitals in southern Vietnam, compared with infants admitted with fever not due to dengue. We show that infants with dengue are difficult to distinguish from those with other febrile illnesses based on signs and symptoms at presentation, and so laboratory tests to confirm dengue virus infection may be useful for diagnosis and management. Conventional diagnostic methods for dengue have low sensitivity early in infection, and we show that an alternative antigen-detection assay that has demonstrated good sensitivity and specificity in older age groups also performs well in infants. This study will help to inform the diagnosis and management of dengue in infants
CO-INFECTION OF DENGUE VIRUS BY SEROTYPES 1 AND 4 IN PATIENT FROM MEDIUM SIZED CITY FROM BRAZIL
SUMMARY The natural co-infection with dengue virus can occur in highly endemic areas where different serotypes have been observed for many years. We report one case of DENV-1/DENV-4 co-infection in human serum detected by molecular tests. Phylogenetic analysis of the sequences obtained indicated the presence of genotype V and II for DENV-1 and DENV-4, respectively
Use of Saliva for Early Dengue Diagnosis
The importance of laboratory diagnosis of dengue cannot be undermined. In recent years, many dengue diagnostic tools have become available for various stages of the disease, but the one limitation is that they require blood as a specimen for testing. In many incidences, phlebotomy in needle-phobic febrile individuals, especially children, can be challenging, and the tendency to forgo a dengue blood test is high. To circumvent this, we decided to work toward a saliva-based assay (antigen-capture anti-DENV IgA ELISA, ACA-ELISA) that has the necessary sensitivity and specificity to detect dengue early. Overall sensitivity of the ACA-ELISA, when tested on saliva collected from dengue-confirmed patients (EDEN study) at three time points, was 70% in the first 3 days after fever onset and 93% between 4 to 8 days after fever onset. In patients with secondary dengue infections, salivary IgA was detected on the first day of fever onset in all the dengue confirmed patients. This demonstrates the utility of saliva in the ACA-ELISA for early dengue diagnostics. This technique is easy to perform, cost effective, and is especially useful in dengue endemic countries
Clinical and Virological Factors Influencing the Performance of a NS1 Antigen-Capture Assay and Potential Use as a Marker of Dengue Disease Severity
Dengue is the most prevalent arthropod-borne disease in tropical regions. The clinical manifestation may vary from asymptomatic to potentially fatal dengue shock syndrome. Early laboratory confirmation of dengue diagnosis is essential since many symptoms are not specific. Dengue non-structural protein 1 (NS1) may be used in simple antigen-capture ELISA for early detection of dengue virus infection. Our result demonstrated that the Platelia NS1 antigen detection kit had a quite low overall sensitivity. However, sensitivity rises significantly when used in combination with MAC-ELISA. When taking into account the various forms of dengue infection, the NS1 antigen detection was found relatively high in patients sampled during the first 3 days of fever onset, in patients with primary infection, DENV-1 infection, with high level of viremia and in mild form of dengue fever. In asymptomatically infected individuals, RT-PCR assay has proved to be more sensitive than NS1 antigen detection. Moreover, the NS1 antigen level correlated significantly with high viremia and low level of NS1 antigen was associated with more severe disease
FALSE-NEGATIVE DENGUE CASES IN RORAIMA, BRAZIL: AN APPROACH REGARDING THE HIGH NUMBER OF NEGATIVE RESULTS BY NS1 AG KITS
Serum samples from 150 NS1-negative (Platelia ELISA) patients presumptively diagnosed with dengue were analyzed by the TaqMan probed real-time reverse transcription PCR (TaqMan qRT-PCR) method. The qRT-PCR positive samples were tested for serotype by semi-nested RT-PCR and a qualitative immunochromatographic assay for IgG and IgM. Molecular detection methods showed 33 (22%) positive samples out of 150 NS1-antigen negative samples. Of these, 72% were collected up to day 2 after the onset of symptoms, when diagnostic sensitivity of NS1-antigen test assays is significantly enhanced. Most of the cases were not characterized as secondary infection. Twenty-eight samples were successfully serotyped, 75% of which for DENV-4, 14% for DENV-2, 7% for DENV-3 and 4% for DENV-1. These findings reaffirm the hyperendemic situation of the state of Roraima and suggest a lower sensitivity of the NS1 test, mainly when DENV-4 is the predominant serotype. Health care providers should therefore be aware of samples tested negative by NS1 antigen assays, especially when clinical symptoms and other laboratory data results show evidence of dengue infection