54 research outputs found

    Cryogenic mechanical loss of a single-crystalline GaP coating layer for precision measurement applications

    Get PDF
    The first direct observations of gravitational waves have been made by the Advanced LIGO detectors. However, the quest to improve the sensitivities of these detectors remains, and epitaxially grown single-crystal coatings show considerable promise as alternatives to the ion-beam sputtered amorphous mirror coatings typically used in these detectors and other such precision optical measurements. The mechanical loss of a 1 μm thick single-crystalline gallium phosphide (GaP) coating, incorporating a buffer layer region necessary for the growth of high quality epitaxial coatings, has been investigated over a broad range of frequencies and with fine temperature resolution. It is shown that at 20 K the mechanical loss of GaP is a factor of 40 less than an undoped tantala film heat-treated to 600 °C and is comparable to the loss of a multilayer GaP/AlGaP coating. This is shown to translate into possible reductions in coating thermal noise of a factor of 2 at 120 K and 5 at 20 K over the current best IBS coatings (alternating stacks of silica and titania-doped tantala). There is also evidence of a thermally activated dissipation process between 50 and 70 K

    The state of the Martian climate

    Get PDF
    60°N was +2.0°C, relative to the 1981–2010 average value (Fig. 5.1). This marks a new high for the record. The average annual surface air temperature (SAT) anomaly for 2016 for land stations north of starting in 1900, and is a significant increase over the previous highest value of +1.2°C, which was observed in 2007, 2011, and 2015. Average global annual temperatures also showed record values in 2015 and 2016. Currently, the Arctic is warming at more than twice the rate of lower latitudes

    Subsequent Surgery After Revision Anterior Cruciate Ligament Reconstruction: Rates and Risk Factors From a Multicenter Cohort

    Get PDF
    BACKGROUND: While revision anterior cruciate ligament reconstruction (ACLR) can be performed to restore knee stability and improve patient activity levels, outcomes after this surgery are reported to be inferior to those after primary ACLR. Further reoperations after revision ACLR can have an even more profound effect on patient satisfaction and outcomes. However, there is a current lack of information regarding the rate and risk factors for subsequent surgery after revision ACLR. PURPOSE: To report the rate of reoperations, procedures performed, and risk factors for a reoperation 2 years after revision ACLR. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: A total of 1205 patients who underwent revision ACLR were enrolled in the Multicenter ACL Revision Study (MARS) between 2006 and 2011, composing the prospective cohort. Two-year questionnaire follow-up was obtained for 989 patients (82%), while telephone follow-up was obtained for 1112 patients (92%). If a patient reported having undergone subsequent surgery, operative reports detailing the subsequent procedure(s) were obtained and categorized. Multivariate regression analysis was performed to determine independent risk factors for a reoperation. RESULTS: Of the 1112 patients included in the analysis, 122 patients (11%) underwent a total of 172 subsequent procedures on the ipsilateral knee at 2-year follow-up. Of the reoperations, 27% were meniscal procedures (69% meniscectomy, 26% repair), 19% were subsequent revision ACLR, 17% were cartilage procedures (61% chondroplasty, 17% microfracture, 13% mosaicplasty), 11% were hardware removal, and 9% were procedures for arthrofibrosis. Multivariate analysis revealed that patients aged <20 years had twice the odds of patients aged 20 to 29 years to undergo a reoperation. The use of an allograft at the time of revision ACLR (odds ratio [OR], 1.79; P = .007) was a significant predictor for reoperations at 2 years, while staged revision (bone grafting of tunnels before revision ACLR) (OR, 1.93; P = .052) did not reach significance. Patients with grade 4 cartilage damage seen during revision ACLR were 78% less likely to undergo subsequent operations within 2 years. Sex, body mass index, smoking history, Marx activity score, technique for femoral tunnel placement, and meniscal tearing or meniscal treatment at the time of revision ACLR showed no significant effect on the reoperation rate. CONCLUSION: There was a significant reoperation rate after revision ACLR at 2 years (11%), with meniscal procedures most commonly involved. Independent risk factors for subsequent surgery on the ipsilateral knee included age <20 years and the use of allograft tissue at the time of revision ACLR

    LIGO-P070088-P Modal frequency degeneracy in thermally loaded optical resonators

    No full text
    We observe power coupling from the fundamental mode to frequency-degenerate higher-order spatial modes in optical resonators illuminated with a 30 W laser. Thermally-induced modal frequency degeneracy facilitates power transfer from the fundamental mode to higher-order modes, reduces power coupling into the cavity, and triggers power fluctuations. Modeling thermoelastic deformation of a mirror’s surface shows predicted modal frequency degeneracy to be in reasonable agreement with experimental observations. Predictions for the Laser Interferometer Gravitational-wave Observatory (LIGO) show that the circulating fundamental-mode power necessary for gravitational-wave detection is compromised at coating absorptions of 3.8 and 0:44 ppm for Enhanced and Advanced LIGO Fabry–Pérot cavities
    corecore