757 research outputs found

    Augmentation of Rotator Cuff Repair With Soft Tissue Scaffolds

    Get PDF
    Background Tears of the rotator cuff are one of the most common tendon disorders. Treatment often includes surgical repair, but the rate of failure to gain or maintain healing has been reported to be as high as 94%. This has been substantially attributed to the inadequate capacity of tendon to heal once damaged, particularly to bone at the enthesis. A number of strategies have been developed to improve tendon-bone healing, tendon-tendon healing, and tendon regeneration. Scaffolds have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects but may not possess situation-specific or durable mechanical and biological characteristics. Purpose To provide an overview of the biology of tendon-bone healing and the current scaffolds used to augment rotator cuff repairs. Study Design Systematic review; Level of evidence, 4. Methods A preliminary literature search of MEDLINE and Embase databases was performed using the terms rotator cuff scaffolds, rotator cuff augmentation, allografts for rotator cuff repair, xenografts for rotator cuff repair, and synthetic grafts for rotator cuff repair. Results The search identified 438 unique articles. Of these, 214 articles were irrelevant to the topic and were therefore excluded. This left a total of 224 studies that were suitable for analysis. Conclusion A number of novel biomaterials have been developed into biologically and mechanically favorable scaffolds. Few clinical trials have examined their effect on tendon-bone healing in well-designed, long-term follow-up studies with appropriate control groups. While there is still considerable work to be done before scaffolds are introduced into routine clinical practice, there does appear to be a clear indication for their use as an interpositional graft for large and massive retracted rotator cuff tears and when repairing a poor-quality degenerative tendon

    Supraspinatus detachment causes musculotendinous degeneration and a reduction in bone mineral density at the enthesis in a rat model of chronic rotator cuff degeneration

    Get PDF
    BACKGROUND: To evaluate biological strategies that enhance tendon-bone healing in humans, it is imperative that suitable animal models accurately reproduce the pathological changes observed in the clinical setting following a tear. The purpose of the present study was to investigate rotator cuff degeneration in a rat, as well as assess the development of osteopenia at the enthesis following tendon detachment. METHODS: Eighteen female Wistar rats underwent unilateral detachment of the supraspinatus tendon. Specimens were retrieved at 4 weeks (n = 6), 6 weeks (n = 6) and 9 weeks (n = 6) postoperatively for histological analysis and peripheral quantitative computer tomography. RESULTS: Three weeks following tendon detachment, there was a significant increase in the modified Movin score, characterized by a loss of muscle mass, fatty infiltration, an increase in musculotendinous cellularity, loss of normal collagen fibre structure/arrangement, rounded tenocyte nuclei and an increase in the number of vascular bundles. This was accompanied by a reduction in bone mineral density at the tendon insertion site. After 3 weeks however, these changes were less prominent. CONCLUSIONS: The rotator cuff tendon-muscle-bone unit in a rat model 3 weeks after detachment of supraspinatus represents a valid model for investigating rotator cuff degeneration

    Ambulatory blood pressure monitoring and morning surge in blood pressure in adult black and white South Africans

    Get PDF
    We examined whether there were differences in the circadian variation in blood pressure and the morning surge in blood pressure between black and white Africans. Clinic and ambulatory blood pressure data obtained from the Sympathetic Activity and Ambulatory Blood Pressure in Africans (SABPA) study was examined (n = 406; 49% black African). Ambulatory blood pressure readings were fitted to a six-parameter double logistic equation to determine the power and rate of the morning surge in blood pressure. Multiple linear regression analysis was used to examine differences in blood pressure between black and white participants. Clinic and ambulatory blood pressure were higher in black participants throughout the day and night. In those taking medications, blood pressure was less well controlled in black subjects. Despite the higher systolic blood pressure, the day-night difference estimated by the logistic function was similar in black and white participants. However, the rate of rise and power in the morning surge in blood pressure was lower in black participants. We conclude that black participants of the SABPA study present with higher blood pressure throughout the day and night but have a lower power of the morning surge in blood pressure due to a slower morning rate of increase. Moreover, they had an increased prevalence of undiagnosed hypertension and, in those taking medication, were less likely to have their blood pressure controlled than their white counterparts

    \Omega-deformation of B-twisted gauge theories and the 3d-3d correspondence

    Full text link
    We study \Omega-deformation of B-twisted gauge theories in two dimensions. As an application, we construct an \Omega-deformed, topologically twisted five-dimensional maximally supersymmetric Yang-Mills theory on the product of a Riemann surface Σ\Sigma and a three-manifold MM, and show that when Σ\Sigma is a disk, this theory is equivalent to analytically continued Chern-Simons theory on MM. Based on these results, we establish a correspondence between three-dimensional N=2\mathcal{N} = 2 superconformal theories and analytically continued Chern-Simons theory. Furthermore, we argue that there is a mirror symmetry between {\Omega}-deformed two-dimensional theories.Comment: 26 pages. v2: the discussion on the boundary condition for vector multiplet improved, and other minor changes mad

    A microfluidics-based in situ chemotaxis assay to study the behaviour of aquatic microbial communities

    Full text link
    © 2017 The Author(s). Microbial interactions influence the productivity and biogeochemistry of the ocean, yet they occur in miniscule volumes that cannot be sampled by traditional oceanographic techniques. To investigate the behaviours of marine microorganisms at spatially relevant scales, we engineered an in situ chemotaxis assay (ISCA) based on microfluidic technology. Here, we describe the fabrication, testing and first field results of the ISCA, demonstrating its value in accessing the microbial behaviours that shape marine ecosystems

    On instantons as Kaluza-Klein modes of M5-branes

    Full text link
    Instantons and W-bosons in 5d maximally supersymmetric Yang-Mills theory arise from a circle compactification of the 6d (2,0) theory as Kaluza-Klein modes and winding self-dual strings, respectively. We study an index which counts BPS instantons with electric charges in Coulomb and symmetric phases. We first prove the existence of unique threshold bound state of (noncommutative) U(1) instantons for any instanton number, and also show that charged instantons in the Coulomb phase correctly give the degeneracy of SU(2) self-dual strings. By studying SU(N) self-dual strings in the Coulomb phase, we find novel momentum-carrying degrees on the worldsheet. The total number of these degrees equals the anomaly coefficient of SU(N) (2,0) theory. We finally show that our index can be used to study the symmetric phase of this theory, and provide an interpretation as the superconformal index of the sigma model on instanton moduli space.Comment: 54 pages, 2 figures. v2: references added, figure improved, added comments on self-dual string anomaly, added new materials on the symmetric phase index, other minor correction

    Charged Chiral Fermions from M5-Branes

    Get PDF
    We study M5-branes wrapped on a multi-centred Taub-NUT space. Reducing to String Theory on the circle fibration leads to D4-branes intersecting with D6-branes. D-braneology shows that there are additional charged chiral fermions from the open strings which stretch between the D4-branes and D6-branes. From the M-theory point of view the appearance of these charged states is mysterious as the M5-branes are wrapped on a smooth manifold. In this paper we show how these states arise in the M5-brane worldvolume theory and argue that are governed by a WZWN-like model where the topological term is five-dimensional.Comment: A reference to an equation number was correcte

    Application of a Demineralized Cortical Bone Matrix and Bone Marrow-Derived Mesenchymal Stem Cells in a Model of Chronic Rotator Cuff Degeneration

    Get PDF
    BACKGROUND: The success of rotator cuff repair is primarily dependent on tendon-bone healing. Failure is common because weak scar tissue replaces the native enthesis, rendering it prone to reruptures. A demineralized bone matrix (DBM) consists of a network of collagen fibers that provide a sustained release of growth factors such as bone morphogenetic proteins. Previous studies have demonstrated that it can regenerate a fibrocartilaginous enthesis. HYPOTHESIS: The use of a DBM and mesenchymal stem cells (MSCs) at the healing enthesis will result in a higher bone mineral density at the tendon insertion and will enhance the regeneration of a morphologically superior enthesis when compared with an acellular human dermal matrix. STUDY DESIGN: Controlled laboratory study. METHODS: Eighteen female Wistar rats underwent unilateral detachment of the supraspinatus tendon. Three weeks later, tendon repair was carried out in animals randomized into 3 groups: group 1 received augmentation of the repair with a cortical allogenic DBM (n = 6); group 2 received augmentation with a nonmeshed, ultrathick, acellular human dermal matrix (n = 6); and group 3 underwent tendon-bone repair without a scaffold (n = 6). All animals received 1 × 10(6) MSCs delivered in fibrin glue to the repair site. Specimens were retrieved at 6 weeks postoperatively for histological analysis and the evaluation of bone mineral density. RESULTS: All groups demonstrated closure of the tendon-bone gap with a fibrocartilaginous enthesis. Although there were no significant differences in the enthesis maturation and modified Movin scores, repair augmented with a dermal matrix + MSCs exhibited a disorganized enthesis, abnormal collagen fiber arrangement, and greater cellularity compared with other MSC groups. Only repairs augmented with a DBM + MSCs reached a bone mineral density not significantly lower than nonoperated controls. CONCLUSION: A DBM enhanced with MSCs can augment rotator cuff healing at 6 weeks and restore bone mineral density at the enthesis to its preinjury levels. CLINICAL RELEVANCE: Biological augmentation of rotator cuff repair with a DBM and MSCs may reduce the incidence of retears, although further studies are required to determine its effectiveness

    The effectiveness of demineralized cortical bone matrix in a chronic rotator cuff tear model.

    Get PDF
    BACKGROUND: The purpose of this study was to assess the effect of demineralized bone matrix (DBM) on rotator cuff tendon-bone healing. The hypothesis was that compared with a commercially available dermal matrix scaffold, DBM would result in a higher bone mineral density and regenerate a morphologically superior enthesis in a rat model of chronic rotator cuff degeneration. METHODS: Eighteen female Wistar rats underwent unilateral detachment of the supraspinatus tendon. Three weeks later, tendon repair was carried out in animals randomized into 3 groups: group 1 animals were repaired with DBM (n = 6); group 2 received augmentation with the dermal scaffold (n = 6); and group 3 (controls) underwent nonaugmented tendon-bone repair (n = 6). Specimens were retrieved at 6 weeks postoperatively for histologic analysis and evaluation of bone mineral density. RESULTS: No failures of tendon-bone healing were noted throughout the study. All groups demonstrated closure of the tendon-bone gap with a fibrocartilaginous interface. Dermal collagen specimens exhibited a disorganized structure with significantly more abnormal collagen fiber arrangement and cellularity than in the DBM-based repairs. Nonaugmented repairs exhibited a significantly higher bone mineral density than in DBM and the dermal collagen specimens and were not significantly different from control limbs that were not operated on. CONCLUSION: The application of DBM to a rat model of chronic rotator cuff degeneration did not improve the composition of the healing enthesis compared with nonaugmented controls and a commercially available scaffold. However, perhaps the most important finding of this study was that the control group demonstrated a similar outcome to augmented repairs
    corecore