1,406 research outputs found

    The addition of morpholine to unsaturated esters

    Full text link
    Thesis (M.A.)--Boston University, 1948. This item was digitized by the Internet Archive

    Unusual ISS Rate Signature

    Get PDF
    On November 23, 2011 International Space Station Guidance, Navigation, and Control reported unusual pitch rate disturbance. These disturbances were an order of magnitude greater than nominal rates. The Loads and Dynamics team was asked to review and analyze current accelerometer data to investigate this disturbance. This paper will cover the investigation process under taken by the Loads and Dynamics group. It will detail the accelerometers used and analysis performed. The analysis included performing Frequency Fourier Transform of the data to identify the mode of interest. This frequency data is then reviewed with modal analysis of the ISS system model. Once this analysis is complete and the disturbance quantified, a forcing function was produced to replicate the disturbance. This allows the Loads and Dynamics team to report the load limit values for the 100's of interfaces on the ISS

    ISS Microgravity Environment

    Get PDF
    The Microgravity performance assessment of the International Space Station (ISS) is comprised of a quasi-steady, structural dynamic and a vibro-acoustic analysis of the ISS assembly-complete vehicle configuration. The Boeing Houston (BHOU) Loads and Dynamics Team is responsible to verify compliance with the ISS System Specification (SSP 41000) and USOS Segment (SSP 41162) microgravity requirements. To verify the ISS environment, a series of accelerometers are on-board to monitor the current environment. This paper summarizes the results of the analysis that was performed for the Verification Analysis Cycle (VAC)-Assembly Complete (AC) and compares it to on-orbit acceleration values currently being reported. The analysis will include the predicted maximum and average environment on-board ISS during multiple activity scenario

    International Space Station 2A Array Modal Analysis

    Get PDF
    On December 9th 2009, the International Space Station (ISS) 2A solar array mast experienced prolonged longeron shadowing during a Soyuz undocking. Analytical reconstruction of induced thermal and dynamic structural loads showed an exceedance of the mast buckling limit. Possible structural damage to the solar array mast could have occurred during this event. A Low fidelity video survey of the 2A mast showed no obvious damage of the mast longerons or battens. The decision was made to conduct an on-orbit dynamic test of the 2A array on December 18th, 2009. The test included thruster pluming on the array while photogrammetry data was recorded. The test was similar to other Dedicated Thruster Firings (DTFs) that were performed to measure structural frequency and damping of a solar array. Results of the DTF indicated lower frequency mast modes than model predictions, thus leading to speculation of mast damage. A detailed nonlinear analysis was performed on the 2A array model to assess possible solutions to modal differences. The setup of the parametric nonlinear trade study included the use of a detailed array model and the reduced mass and stiffness matrices of the entire ISS being applied to the array interface. The study revealed that the array attachment structure is nonlinear and thus was the source of error in the model prediction of mast modes. In addition, a detailed study was performed to determine mast mode sensitivity to mast longeron damage. This sensitivity study was performed to assess if the ISS program has sufficient instrumentation for mast damage detection

    Introduction to Reciprocating Compressor Diagnostics and Pattern Interpretation

    Get PDF
    Short Cours

    International Space Station Microgravity Analytical Model Correlation And Update

    Get PDF
    The acceleration environment aboard the completed International Space Station (ISS) is a key resource for scientific and technological endeavors. Hardware verification activIties and early measurements indicate that the ISS is well on the way of meeting these "Assembly Complete" "microgravity" provisions, however, the simulation models that compute these accelerations have, to date, lacked the high degree of empirical validation typical of standard aerospace industry practices. Assembly stage, on-orbit measurements are used to address this shortcoming and to develop higher confidence in the simulation models. The Phase I correlation results show the analyses to be consistently conservative, producing higher than measured levels. The 25 to 30% greater quasi-steady computations are deemed acceptable for verification. Updates are made to localized structural dynamic and vibroacoustic parameters that reduce responses in selected one-third octave bands by almost 50%. These models are then used for the Assembly Complete verification analysis which concludes that the ISS vehicle meets the ISS microgravity requirements with minor reservations. Two of the sixteen rack are marginally non-compliant in the quasi-steady regime, and operational constraints are needed on the U. S. Lab and ESA APM vacuum resource vents, and the Russian Resistive Exercise Device in the structural dynamic regime

    Antimicrobial properties of nanostructured surfaces - demonstrating the need for a standard testing methodology

    Get PDF
    Bioinspired nanostructured materials that exhibit antimicrobial properties are being synthesized and tested at increasing rates for use in healthcare, manufacturing processes, and diagnostics. Although progress has been made in improving and understanding their bactericidal activity, arguably, the biggest problem currently in the field is the lack of a standard testing methodology that allows for optimal characterization and better comparison of emerging nanostructures. Here, we examine two forms of nanostructured silicon that vary in their ability to kill certain bacterial species due to different physical mechanisms and derive guidelines for the comparative testing. We perform a comprehensive evaluation of methodologies used extensively in the field (e.g., colony counting and live dead analysis) and the novel application of high-throughput flow cytometry. The data reveal how the techniques are complementary but not always directly equivalent or correlative. Therefore, comparison of results obtained using different methodologies on different materials can be grossly misleading. We report significant variations in bactericidal efficiencies depending on experimental environments (medium type, etc.) and methodologies employed. In addition, we demonstrate how cytometry is yet another powerful complementary tool that can aid the mechanistic understanding of antimicrobial activities of rough surfaces. Besides standardization for comparison, ultimately, evaluation methods need to consider anticipated applications. Then and only then can the true potential (or limitation) of a novel material be determined for its suitability for advancement in a particular field of use

    Magnetresonanztomographische kardiovaskuläre Ganzkörperuntersuchung mit paralleler Bildgebung

    Get PDF
    Wir führten eine MRT-Studie mit Probanden durch. Wir wendeten dabei bei jedem Probanden eine Ganzkörper- Magnetresonanz (GK-MR)- Tomographie, eine GK-MR- Angiographie und eine Kardio-MRT zum Screening auf kardiovaskuläre und Tumorerkrankungen an. Neu an dieser Untersuchung ist die Kombination dieser bislang in Einzelprotokollen eingesetzten Untersuchungsschritte in ein integriertes GK-MR-Protokoll. Ziel dieser Studie war es die technische Machbarkeit dieses GK-MR-Protokolles zu zeigen und zum anderen die diagnostische Wertigkeit überprüfen. Wir schlossen 138 beschwerdefreie Angestellte zweier Unternehmen wurden eingeschlossen, nachdem es in einer ausführlichen Anamnese keine Hinweise auf kardiovaskuläre oder maligne Erkrankungen gab. Alle Teilnehmer komplettierten die gesamte Untersuchung. Die Untersuchungszeit lag in den allermeisten Fällen bei knapp 90 Minuten. Das ist eine gemeinhin als noch tolerabel eingeschätzte Untersuchungszeit für Routinemessungen. In allen Fällen wurde eine gute bis sehr gute diagnostische Bildqualität erzielt. Wir fanden bei ca. 84% der Patienten pathologische Befunde. Davon waren allerdings nur ca. 35% für eine weitere Abklärung, Kontrolle oder Therapieinitiierung relevant. Die Mehrzahl der pathologischen Befunde fanden wir im vaskulären System (32% aller pathologischen Befunde), am häufigsten im Bereich der Beinarterien (35% aller vaskulären Befunde oder absolut 9,3%). Keiner der Probanden musste einer Operation oder angiographischen Intervention zugeführt werden. Wir fanden lediglich gering- oder mittelgradige Stenosen, die im Verlauf kontrolliert werden sollten. In der Kardio-MRT fanden wir bei 6 Probanden eine Wandbewegungsstörungen, bei 2 Fällen eine verzögerte Kontrastmittelanreicherung, bei 12 einen Perfusionsdefekt. Diese Befunde sprechen für eine abgelaufene Myokardischämie. Klappenvitien fanden wir bei 9 Prob. Sowie eine Perikarditis und eine Perikardzyste, eine eingeschränkt myokardiale Globalfunktion, 4 Mal Hinweise für eine Myokardhypertrophie. In dem Tumorscreening fanden wir kein Malignom, aber ein Meningeom, welches sich auch in einer dezidierten MRT des Neurocraniums bestätigte, histologisch bislang jedoch nicht gesichert ist. Wir fanden außerdem eine asymptomatisch abgelaufene cerebrale Ischämie. Wir stellten Häufigkeiten für Pathologien in der GK-MRT und auch die in der MR-Angiographie in unserem Kollektiv fest, die denen vergleichbarer Kollektive in der Literatur weitestgehend entsprechen. Auch die Ergebnisse der Herz-MRT-Untersuchung korrelieren gut mit Kardio-MRT Studien an Probanden. Limitierend an unserer Studie ist der fehlende Vergleich zum jeweilig anerkannten Goldstandard. Diese wäre Ultraschall, CT, CT-Angiographie und konventionelle digitale Subtraktionsangiographie. Bei der Untersuchung von Probanden war es nicht zu rechtfertigen Strahlung zu applizieren. Auch wollten wir unsere Probanden unter keinen Umständen durch Anwendung jodhaltigen Kontrastmittels gefährden. Ultraschall könnte als Goldstandard für die MRA eine gute nicht invasive Alternative darstellen. Die Darstellung des gesamten arteriellen Gefäßsystems ist jedoch nur diskontinuierlich möglich, sehr aufwändig und zudem untersucherabhängig. Die Kardio-MRT hätte mit der Echokardiographie als Goldstandard vergleichen werden können. Diese führten wir in unserer Studie jedoch nur auf Einzelfallebene durch. Aufgrund der Rekrutierung des Kollektives ist darüber hinaus ein Selektions-Bias zu erwarten. Das vorliegende GK-MR-Protokoll zeigte eine gute klinische Anwendbarkeit und Akzeptanz. Die nicht geringe Anzahl detektiereter kontrollbedürftiger Befunde veranlasste uns diesen Studienteilnehmern zur Prophylaxe potentiell letaler kardiovaskulärer Ereignisse engermaschige Kontrollen anzubieten
    corecore