310 research outputs found

    Pyometra in Bitches Induces Elevated Plasma Endotoxin and Prostaglandin F(2α )Metabolite Levels

    Get PDF
    Endotoxemia in bitches with pyometra can cause severe systemic effects directly or via the release of inflammatory mediators. Plasma endotoxin concentrations were measured in ten bitches suffering from pyometra with moderately to severely deteriorated general condition, and in nine bitches admitted to surgery for non-infectious reasons. Endotoxin samples were taken on five occasions before, during and after surgery. In addition, urine and uterine bacteriology was performed and hematological, blood biochemical parameters, prostaglandin F(2α )metabolite 15-ketodihydro-PGF(2α )(PG-metabolite), progesterone and oestradiol (E(2)-17ÎČ) levels were analysed. The results confirm significantly increased plasma levels of endotoxin in bitches with pyometra and support previous reports of endotoxin involvement in the pathogenesis of the disease. Plasma concentrations of PG-metabolite were elevated in pyometra bitches and provide a good indicator of endotoxin release since the concentrations were significantly correlated to the endotoxin levels and many other hematological and chemistry parameters. The Îł-globulin serum protein electrophoresis fraction and analysis of PG-metabolite can be valuable in the diagnosis of endotoxin involvement if a reliable, rapid and cost-effective test for PG-metabolite analysis becomes readily available in the future. Treatment inhibiting prostaglandin biosynthesis and related compounds could be beneficial for bitches suffering from pyometra

    Change of Diurnal Heart Rate Patterns During Pregnancy and Lactation in Dogs (Canis familiaris)

    Get PDF
    Pregnancy and lactation involve great demands on the cardiovascular system. The purpose of this study was to investigate how the heart rate and diurnal heart rate pattern change when dogs become pregnant or lactate. Five clinically healthy female beagle dogs were mated, and delivered three to seven healthy puppies. The heart rate was investigated with 24-h ECG (Holter) once during anoestrus, at 3, 5, 7 and 9 weeks of pregnancy, and at week 4 postpartum (lactation). However, at 9 weeks, the ECG could not be recorded for the fully 24 h in 4 of 5 dogs, because labour started and the dogs then appeared disturbed by the recordings. The results at this date are not included in the statistical comparison. The heart rate increased progressively during pregnancy and was still elevated at 4 weeks of lactation. During late pregnancy the difference in heart rates between daytime and nighttime became smaller, but the heart rate was significantly higher in daytime in all periods. In conclusion, the increased heart rates during pregnancy and lactation reflect increased demands on the cardiovascular system and may be important to consider in clinical practice

    Improved metrics for comparing structures of macromolecular assemblies determined by 3D electron-microscopy

    Get PDF
    Recent developments in 3-dimensional electron microcopy (3D-EM) techniques and a concomitant drive to look at complex molecular structures, have led to a rapid increase in the amount of volume data available for biomolecules. This creates a demand for better methods to analyse the data, including improved scores for comparison, classification and integration of data at different resolutions. To this end, we developed and evaluated a set of scoring functions that compare 3D-EM volumes. To test our scores we used a benchmark set of volume alignments derived from the Electron Microscopy Data Bank. We find that the performance of different scores vary with the map-type, resolution and the extent of overlap between volumes. Importantly, adding the overlap information to the local scoring functions can significantly improve their precision and accuracy in a range of resolutions. A combined score involving the local mutual information and overlap (LMI_OV) performs best overall, irrespective of the map category, resolution or the extent of overlap, and we recommend this score for general use. The local mutual information score itself is found to be more discriminatory than cross-correlation coefficient for intermediate-to-low resolution maps or when the map size and density distribution differ significantly. For comparing map surfaces, we implemented two filters to detect the surface points, including one based on the ‘extent of surface exposure’. We show that scores that compare surfaces are useful at low resolutions and for maps with evident surface features. All the scores discussed are implemented in TEMPy (http://tempy.ismb.lon.ac.uk/)

    Fixation of a double-coated titanium-hydroxyapatite focal knee resurfacing implant A 12-month study in sheep

    Get PDF
    SummaryObjectiveFocal cartilage lesions according to International Cartilage Repair Society (ICRS) grade 3–4 in the medial femoral condyle may progress to osteoarthritis. When treating such focal lesions with metallic implants a sound fixation to the underlying bone is mandatory. We developed a monobloc unipolar cobalt-chrome (Co-Cr) implant with a double coating; first a layer of commercially pure titanium (c.p.Ti) on top of which a layer of hydroxyapatite (HA) was applied. We hypothesised that such a double coating would provide long-lasting and adequate osseointegration.Design (materials and methods)Unilateral medial femoral condyles of 10 sheep were operated. The implants were inserted in the weight-bearing surface and immediate weight-bearing was allowed. Euthanasia was performed at 6 (three animals) or 12 months (six animals). Osseointegration was analysed with micro-computer tomography (CT), light microscopy and histomorphometric analyses using backscatter scanning electron microscopy (B-SEM) technique.ResultsAt 6 months one specimen out of three showed small osteolytic areas at the hat and at 12 months two specimens out of six showed small osteolytic areas at the hat, no osteolytical areas were seen around the peg at any time point. At both time points, a high total bone-to-implant contact was measured with a mean (95% confidence interval – CI) of 90.6 (79–102) at 6 months and 92.3 (89–95) at 12 months, respectively.ConclusionsA double coating (Ti + HA) of a focal knee resurfacing Co-Cr implant was presented in a sheep animal model. A firm and consistent bond to bone under weight-bearing conditions was shown up to 1 year

    Progress and challenges to the global waste management system

    Get PDF
    Rapid economic growth, urbanization and increasing population have caused (materially intensive) resource consumption to increase, and consequently the release of large amounts of waste to the environment. From a global perspective, current waste and resource management lacks a holistic approach covering the whole chain of product design, raw material extraction, production, consumption, recycling and waste management. In this article, progress and different sustainability challenges facing the global waste management system are presented and discussed. The study leads to the conclusion that the current, rather isolated efforts, in different systems for waste management, waste reduction and resource management are indeed not sufficient in a long term sustainability perspective. In the future, to manage resources and wastes sustainably, waste management requires a more systems-oriented approach that addresses the root causes for the problems. A specific issue to address is the development of improved feedback information (statistics) on how waste generation is linked to consumption

    Smooth-muscle myosin mutations in hereditary non-polyposis colorectal cancer syndrome

    Get PDF
    We examined adenomas and cancers from hereditary non-polyposis colorectal cancer (HNPCC) syndrome patients for the presence of frameshift mutations in the smooth-muscle myosin gene, MYH11. Our results show that mutations in MYH11 occur more frequently in cancers than adenomas (P=0.008) and are dependent on microsatellite instability (MSI+)
    • 

    corecore