13 research outputs found

    Efficacy And Safety Of Implantable Loop Recorder: Experience Of A Center

    Get PDF
    Introduction: Symptoms like syncope or palpitations frequently present a diagnostic challenge. An implantable loop recorder (ILR) is an important aid in the management of these patients. Methods: A retrospective study of patients that underwent ILR implantation from November 2007 to 2014. For each patient the indication for implantation, baseline characteristics, previous study, complications, recorded tracing and interventions were evaluated. Results: A total of 62 patients were included, 50% men, with a mean age of 62.5±18.8 years old. Previously to ILR implantation 88.7% of patients had performed Holter, 17.7% external events recorder, 33.9% Tilt test and 29% an electrophysiological study. The implantation indications were recurrent syncope in 90.3%, palpitations 8.1% and ischemic stroke in one patient. Mean follow-up time was 17.1±16.3 months. Symptoms were reported in 66.1% of the patients, 46.8% of those yielding a diagnostic finding. In all cases of palpitation complaints with diagnosis we found atrial fibrillation (AF). In patients with syncope atrioventricular conduction disturbance was demonstrated in 19.6%, sinus node dysfunction in 16.1%, paroxysmal supra-ventricular tachycardia 7.1% and AF in 1.8%. These finding resulted in 19 pacemaker and one CRT-D implantation, introduction of anticoagulation in five patients and one ablation of accessory pathway. There were no major complications. Conclusion: ILR proved to be safe and efficient. It has enabled the identification or exclusion of serious rhythm disturbances in more than half of patients and provided a targeted therapeutic intervention.info:eu-repo/semantics/publishedVersio

    Real-time multispectral fluorescence lifetime imaging using Single Photon Avalanche Diode arrays

    Get PDF
    Autofluorescence spectroscopy has emerged in recent years as a powerful tool to report label-free contrast between normal and diseased tissues, both in vivo and ex vivo. We report the development of an instrument employing Single Photon Avalanche Diode (SPAD) arrays to realize real-time multispectral autofluorescence lifetime imaging at a macroscopic scale using handheld single-point fibre optic probes, under bright background conditions. At the detection end, the fluorescence signal is passed through a transmission grating and both spectral and temporal information are encoded in the SPAD array. This configuration allows interrogation in the spectral range of interest in real time. Spatial information is provided by an external camera together with a guiding beam that provides a visual reference that is tracked in real-time. Through fast image processing and data analysis, fluorescence lifetime maps are augmented on white light images to provide feedback of the measurements in real-time. We validate and demonstrate the practicality of this technique in the reference fluorophores and in articular cartilage samples mimicking the degradation that occurs in osteoarthritis. Our results demonstrate that SPADs together with fibre probes can offer means to report autofluorescence spectral and lifetime contrast in real-time and thus are suitable candidates for in situ tissue diagnostics

    Multispectral depth-resolved fluorescence lifetime spectroscopy using SPAD array detectors and fiber probes

    No full text
    Single Photon Avalanche Diode (SPAD) arrays are increasingly exploited and have demonstrated potential in biochemical and biomedical research, both for imaging and single-point spectroscopy applications. In this study, we explore the application of SPADs together with fiber-optic-based delivery and collection geometry to realize fast and simultaneous single-point time-, spectral-, and depth-resolved fluorescence measurements at 375 nm excitation light. Spectral information is encoded across the columns of the array through grating-based dispersion, while depth information is encoded across the rows thanks to a linear arrangement of probe collecting fibers. The initial characterization and validation were realized against layered fluorescent agarose-based phantoms. To verify the practicality and feasibility of this approach in biological specimens, we measured the fluorescence signature of formalin-fixed rabbit aorta samples derived from an animal model of atherosclerosis. The initial results demonstrate that this detection configuration can report fluorescence spectral and lifetime contrast originating at different depths within the specimens. We believe that our optical scheme, based on SPAD array detectors and fiber-optic probes, constitute a powerful and versatile approach for the deployment of multidimensional fluorescence spectroscopy in clinical applications where information from deeper tissue layers is important for diagnosis

    Intraoperative transfusion practices in Europe

    Get PDF
    BACKGROUND: Transfusion of allogeneic blood influences outcome after surgery. Despite widespread availability of transfusion guidelines, transfusion practices might vary among physicians, departments, hospitals and countries. Our aim was to determine the amount of packed red blood cells (pRBC) and blood products transfused intraoperatively, and to describe factors determining transfusion throughout Europe. METHODS: We did a prospective observational cohort study enrolling 5803 patients in 126 European centres that received at least one pRBC unit intraoperatively, during a continuous three month period in 2013. RESULTS: The overall intraoperative transfusion rate was 1.8%; 59% of transfusions were at least partially initiated as a result of a physiological transfusion trigger- mostly because of hypotension (55.4%) and/or tachycardia (30.7%). Haemoglobin (Hb)- based transfusion trigger alone initiated only 8.5% of transfusions. The Hb concentration [mean (sd)] just before transfusion was 8.1 (1.7) g dl(-1) and increased to 9.8 (1.8) g dl(-1) after transfusion. The mean number of intraoperatively transfused pRBC units was 2.5 (2.7) units (median 2). CONCLUSION: Although European Society of Anaesthesiology transfusion guidelines are moderately implemented in Europe with respect to Hb threshold for transfusion (7-9 g dl(-1)), there is still an urgent need for further educational efforts that focus on the number of pRBC units to be transfused at this threshold. CLINICAL TRIAL REGISTRATION: NCT 01604083
    corecore