81 research outputs found

    Minimizing Stimulus Current in a Wearable Pudendal Nerve Stimulator Using Computational Models.

    Get PDF
    After spinal cord injury, functions of the lower urinary tract may be disrupted. A wearable device with surface electrodes which can effectively control the bladder functions would be highly beneficial to the patients. A trans-rectal pudendal nerve stimulator may provide such a solution. However, the major limiting factor in such a stimulator is the high level of current it requires to recruit the nerve fibers. Also, the variability of the trajectory of the nerve in different individuals should be considered. Using computational models and an approximate trajectory of the nerve derived from an MRI study, it is demonstrated in this paper that it may be possible to considerably reduce the required current levels for trans-rectal stimulation of the pudendal nerve compared to the values previously reported in the literature. This was corroborated by considering an ensemble of possible and probable variations of the trajectory. The outcome of this study suggests that trans-rectal stimulation of the pudendal nerve is a plausible long term solution for treating lower urinary tract dysfunctions after spinal cord injury

    A novel inhaled phosphodiesterase 4 inhibitor (CHF6001) reduces the allergen challenge response in asthmatic patients

    Get PDF
    CHF6001 is an inhaled phosphodiesterase 4 (PDE4) inhibitor in development for the treatment of obstructive lung diseases. We investigated the efficacy and safety of CHF6001 using the allergen challenge model in a double blind, placebo controlled, 3-way cross-over study. Thirty six atopic asthmatics who were not taking inhaled corticosteroids and who demonstrated a late asthmatic response (LAR) to inhaled allergen at screening were randomised to receive CHF6001 400 μg or 1200 μg or placebo administered once a day using a dry powder inhaler. The three treatment periods were 9 days; allergen challenges were performed on day 9 and induced sputum was obtained after 10 h from challenge. Washout periods between treatments were up to 5 weeks. Both CHF6001 doses significantly attenuated the LAR; the primary endpoint analysis showed that CHF6001 400 μg and 1200 μg caused reductions of 19.7% (p = 0.015) and 28.2% (p < 0.001) respectively of the weighted FEV1 AUC4-10h compared with placebo. The difference between the CHF6001 doses was not statistically significant (p = 0.2). Compared with placebo, CHF 6001 caused greater reduction in sputum eosinophil counts, although these changes were not statistically significant. CHF6001 was well tolerated, with similar numbers of adverse events in each treatment period. This inhaled PDE4 inhibitor has the potential to provide clinical benefits in patients with atopic asthma

    Design of sEMG assembly to detect external anal sphincter activity: a proof of concept

    Get PDF
    Objective: Conditional trans-rectal stimulation of the pudendal nerve could provide a viable solution to treat hyperreflexive bladder in spinal cord injury. A set threshold of the amplitude estimate of the external anal sphincter surface electromyography (sEMG) may be used as the trigger signal. The efficacy of such a device should be tested in a large scale clinical trial. As such a probe should remain in situ for several hours while patients attend to their daily routine, the recording electrodes should be designed to be large enough to maintain good contact while observing design constraints. The objective of this study was to arrive at a design for intra-anal sEMG recording electrodes for the subsequent clinical trials while deriving the possible recording and processing parameters. &#13; Approach: Having in mind existing solutions and based on theoretical and anatomical considerations, a set of four multi-electrode probes were designed and developed. These were tested in a healthy subject and the measured sEMG traces were recorded and appropriately processed.&#13; Main results: It was shown that while comparatively large electrodes record sEMG traces that are not sufficiently correlated with the external anal sphincter contractions, smaller electrodes may not maintain a stable electrode tissue contact. It was shown that 3 mm wide and 1 cm long electrodes with 5 mm inter-electrode spacing, in agreement with Nyquist sampling, placed 1 cm from the orifice may intra-anally record a sEMG trace sufficiently correlated with external anal sphincter activity.&#13; Significance: The outcome of this study can be used in any biofeedback, treatment or diagnostic application where the activity of the external anal sphincter sEMG should be detected for an extended period of time

    A comparison of the characteristics of circulating anti-myeloperoxidase autoantibodies in vasculitis with those in non-vasculitic conditions

    No full text
    Although circulating anti-neutrophil cytoplasmic antibodies (ANCA) specific for myeloperoxidase (MPO) are strongly associated with the presence of vasculitis, they have been described in sera from patients with other conditions. High levels of anti-MPO antibodies can also persist in sera from patients with vasculitis despite the achievement of clinical remission. One possible interpretation is that a potentially pathogenic subset of anti-MPO antibodies exists, which is only present in patients with active vasculitis. We therefore compared the characteristics of anti-MPO antibodies in sera from patients with active vasculitis (n = 18) with those present in remission (n = 9) and in a disease control group (n = 10) without clinical evidence of vasculitis. The class, subclass and ability of anti-MPO antibodies from the three groups of patients to recognize three different conformational epitopes were analysed using ELISA-based techniques. The expression of an idiotope, designated 9G4, was also examined. Epitope recognition by anti-MPO antibodies from all patients tested was found to be similar. Sera from patients with active vasculitis showed an over-representation of IgG4 subclass anti-MPO antibodies and a more frequent presence of IgM class anti-MPO antibodies. In disease controls, IgG1 anti-MPO antibodies were predominant. In vitro, neutrophil activation by ANCA has been shown to be dependent on engagement of neutrophil FcγRIIa receptors following binding of these autoantibodies to surface-expressed ANCA antigens. We found that active vasculitis may be associated with the presence of circulating anti-MPO antibodies which do not significantly bind this receptor, suggesting that mechanisms other than those dependent on FcγRIIa binding should be explored. In addition, the expression of the 9G4 idiotope on anti-MPO antibodies in 60% (12/18) of patients with active vasculitis and 20% (2/10) of disease control patients may indicate a common origin for anti-MPO antibodies in different individuals
    • …
    corecore