459 research outputs found

    Urine culture doubtful in determining etiology of diffuse symptoms among elderly individuals: a cross-sectional study of 32 nursing homes

    Get PDF
    Background: The high prevalence of bacteriuria in elderly individuals makes it difficult to know if a new symptom is related to bacteria in the urine. There are different views concerning this relationship and bacteriuria often leads to antibiotic treatments. The aim of this study was to investigate the relationship between bacteria in the urine and new or increased restlessness, fatigue, confusion, aggressiveness, not being herself/himself, dysuria, urgency and fever in individuals at nursing homes for elderly when statistically considering the high prevalence of asymptomatic bacteriuria in this population.\ud \ud Methods: In this cross-sectional study symptoms were registered and voided urine specimens were collected for urinary cultures from 651 elderly individuals. Logistic regressions were performed to evaluate the statistical correlation between bacteriuria and presence of a symptom at group level. To estimate the clinical relevance of statistical correlations at group level positive and negative etiological predictive values (EPV) were calculated.\ud \ud Results: Logistic regression indicated some correlations at group level. Aside from Escherichia coli in the urine and not being herself/himself existing at least one month, but less than three months, EPV indicated no clinically useful correlation between any symptoms in this study and findings of bacteriuria.\ud \ud Conclusions: Urinary cultures provide little or no useful information when evaluating diffuse symptoms among elderly residents of nursing homes. Either common urinary tract pathogens are irrelevant, or urine culture is an inappropriate test

    Evaluation of dipstick analysis among elderly residents to detect bacteriuria: a cross-sectional study in 32 nursing homes

    Get PDF
    Background: Up to half the residents of nursing homes for the elderly have asymptomatic bacteriuria (ABU), which should not be treated with antibiotics. Thus, it is difficult to know if new symptoms in residents with bacteriuria are caused by urinary tract infection (UTI), or if bacteriuria only represents an ABU. This is especially difficult in the presence of non-urinary tract specific symptoms. The diagnostic uncertainty is likely to generate significant overtreatment with UTI antibiotics. Aim: The general aim was to clarify the association between symptoms, bacteriuria, dipstick urinalysis and urine Interleukin-6 (IL-6) among nursing home residents to improve the diagnostic procedure of a suspected lower UTI. Methods: In 2003 a study protocol including newly onset symptoms was completed, and single voided urine specimens collected for dipstick urinalysis and cultures from 651 residents of 32 participating Swedish nursing homes for the elderly. This data was used for a study of dipstick urinalysis (Paper I) and for a study of nonspecific symptoms and bacteriuria (Paper II). In 2012, similar data was collected for 421 elderly residents of 22 nursing homes, which also included an analysis of IL-6 in urine and urine specimens from another 59 residents with urinary catheters. The association between bacteriuria, IL-6 in urine, dipstick urinalysis and newly onset symptoms was analysed (Paper III). Antimicrobial resistance rates were described among residents of nursing homes in 2012 and compared with those from 2003 (Paper IV). Results: Paper I: The negative predictive value for predicting absence of bacteriuria was 88 (84-92)% when dipstick urinalysis for nitrite and leukocyte esterase were simultaneously negative. A positive dipstick or any combination thereof could not sufficiently predict bacteriuria. Papers II-III: New or increased nonspecific symptoms were common among elderly residents of nursing homes. Residents without nonspecific symptoms had positive urine cultures as often as those with nonspecific symptoms with a duration of up to one month. Paper III: Residents with positive urine cultures had higher concentrations of IL-6 in the urine. However, among residents with positive urine cultures there were no differences in IL-6 concentrations or dipstick findings between those with or without nonspecific symptoms. Paper IV: The average rates of antimicrobial resistance were low and did not increase between 2003 and 2012 in Escherichia coli (E. coli) urinary isolates among Swedish nursing home residents. Any antibiotic treatment during the last month and hospitalization during the last six months predicted higher resistance rates among E. coli. Conclusions: Nonspecific symptoms among elderly residents of nursing homes are unlikely to be caused by bacteria in the urine. Therefore, dipstick urinalysis, IL-6 in the urine and urine cultures are of little or no value in clarifying the aetiology of nonspecific symptoms. If there is a reason for testing for bacteriuria, dipstick urinalysis for nitrite and leukocyte esterase can rule out but cannot reliably rule in bacteriuria. Antimicrobial resistance in urinary pathogens among Swedish nursing home residents remained low. It is important to use antibiotics rationally to preserve the effectiveness of antibiotics

    Siblings of patients with Crohn's disease exhibit a biologically relevant dysbiosis in mucosal microbial metacommunities

    Get PDF
    © 2016, BMJ Publishing Group. All rights reserved. Objective: To determine the existence of mucosal dysbiosis in siblings of patients with Crohn's disease (CD) using 454 pyrosequencing and to comprehensively characterise and determine the influence of genotypical and phenotypical factors, on that dysbiosis. Siblings of patients with CD have elevated risk of developing CD and display aspects of disease phenotype, including faecal dysbiosis. Whether the mucosal microbiota is disrupted in these at-risk individuals is unknown. Design: Rectal biopsy DNA was extracted from 21 patients with quiescent CD, 17 of their healthy siblings and 19 unrelated healthy controls. Mucosal microbiota was analysed by 16S rRNA gene pyrosequencing and were classified into core and rare species. Genotypical risk was determined using Illumina Immuno BeadChip, faecal calprotectin by ELISA and blood T-cell phenotype by flow cytometry. Results: Core microbiota of both patients with CD and healthy siblings was significantly less diverse than controls. Metacommunity profiling (Bray-Curtis (SBC) index) showed the sibling core microbial composition to be more similar to CD (SBC=0.70) than to healthy controls, whereas the sibling rare microbiota was more similar to healthy controls (SBC=0.42). Faecalibacterium prausnitzii contributed most to core metacommunity dissimilarity both between siblings and controls, and between patients and controls. Phenotype/genotype markers of CD risk significantly influenced microbiota variation between and within groups, of which genotype had the largest effect. Conclusions: Individuals with elevated CD-risk display mucosal dysbiosis characterised by reduced diversity of core microbiota and lower abundance of F. prausnitzii. This dysbiosis in healthy people at risk of CD implicates microbiological processes in CD pathogenesis

    Numerical Simulation of the Atmospheric Signature of Artificial and Natural Seismic Events

    Get PDF
    The mechanical coupling between solid planets and their atmospheres enables seismically induced acoustic waves to propagate in the atmosphere. We numerically simulate this coupled system for two application cases: active seismic experiments (ASEs) and passive seismic experiments. A recent ASE (Krishnamoorthy et al., 2018, https://doi.org/10.1002/2018GL077481) observed the infrasonic signals produced by a seismic hammer. To measure the sensitivity of observations to seismic parameters, we attempt to reproduce the results from this experiment at short range by considering a realistic unconsolidated subsurface and an idealized rock-solid subsurface. At long range, we investigate the influence of the source by using two focal mechanisms. We found surface waves generate an infrasonic plane head wave in the ASE case of the rock-solid material. For the passive seismic experiments, the amplitude of atmospheric infrasound generated by seismic surface waves is investigated in detail. Despite some limitations, the simulations suggest that balloon measurement of seismically induced infrasound might help to constrain ground properties

    Measurement of the p-pbar -> Wgamma + X cross section at sqrt(s) = 1.96 TeV and WWgamma anomalous coupling limits

    Full text link
    The WWgamma triple gauge boson coupling parameters are studied using p-pbar -> l nu gamma + X (l = e,mu) events at sqrt(s) = 1.96 TeV. The data were collected with the DO detector from an integrated luminosity of 162 pb^{-1} delivered by the Fermilab Tevatron Collider. The cross section times branching fraction for p-pbar -> W(gamma) + X -> l nu gamma + X with E_T^{gamma} > 8 GeV and Delta R_{l gamma} > 0.7 is 14.8 +/- 1.6 (stat) +/- 1.0 (syst) +/- 1.0 (lum) pb. The one-dimensional 95% confidence level limits on anomalous couplings are -0.88 < Delta kappa_{gamma} < 0.96 and -0.20 < lambda_{gamma} < 0.20.Comment: Submitted to Phys. Rev. D Rapid Communication

    Measurement of the ttbar Production Cross Section in ppbar Collisions at sqrt{s} = 1.96 TeV using Kinematic Characteristics of Lepton + Jets Events

    Get PDF
    We present a measurement of the top quark pair ttbar production cross section in ppbar collisions at a center-of-mass energy of 1.96 TeV using 230 pb**{-1} of data collected by the DO detector at the Fermilab Tevatron Collider. We select events with one charged lepton (electron or muon), large missing transverse energy, and at least four jets, and extract the ttbar content of the sample based on the kinematic characteristics of the events. For a top quark mass of 175 GeV, we measure sigma(ttbar) = 6.7 {+1.4-1.3} (stat) {+1.6- 1.1} (syst) +/-0.4 (lumi) pb, in good agreement with the standard model prediction.Comment: submitted to Phys.Rev.Let

    Search for R-parity violating supersymmetry via the LLE couplings lambda_{121}, lambda_{122} or lambda_{133} in ppbar collisions at sqrt(s)=1.96 TeV

    Get PDF
    A search for gaugino pair production with a trilepton signature in the framework of R-parity violating supersymmetry via the couplings lambda_121, lambda_122, or lambda_133 is presented. The data, corresponding to an integrated luminosity of L~360/pb, were collected from April 2002 to August 2004 with the D0 detector at the Fermilab Tevatron Collider, at a center-of-mass energy of sqrt(s)=1.96 TeV. This analysis considers final states with three charged leptons with the flavor combinations eel, mumul, and eetau (l=e or mu). No evidence for supersymmetry is found and limits at the 95% confidence level are set on the gaugino pair production cross section and lower bounds on the masses of the lightest neutralino and chargino are derived in two supersymmetric models.Comment: 9 pages, 4 figures (fig2 includes 3 subfigures

    Measurement of the ttbar Production Cross Section in ppbar Collisions at sqrt(s)=1.96 TeV using Lepton + Jets Events with Lifetime b-tagging

    Get PDF
    We present a measurement of the top quark pair (ttˉt\bar{t}) production cross section (σttˉ\sigma_{t\bar{t}}) in ppˉp\bar{p} collisions at s=1.96\sqrt{s}=1.96 TeV using 230 pb1^{-1} of data collected by the D0 experiment at the Fermilab Tevatron Collider. We select events with one charged lepton (electron or muon), missing transverse energy, and jets in the final state. We employ lifetime-based b-jet identification techniques to further enhance the ttˉt\bar{t} purity of the selected sample. For a top quark mass of 175 GeV, we measure σttˉ=8.61.5+1.6(stat.+syst.)±0.6(lumi.)\sigma_{t\bar{t}}=8.6^{+1.6}_{-1.5}(stat.+syst.)\pm 0.6(lumi.) pb, in agreement with the standard model expectation.Comment: 7 pages, 2 figures, 3 tables Submitted to Phys.Rev.Let

    Search for right-handed W bosons in top quark decay

    Full text link
    We present a measurement of the fraction f+ of right-handed W bosons produced in top quark decays, based on a candidate sample of ttˉt\bar{t} events in the lepton+jets decay mode. These data correspond to an integrated luminosity of 230pb^-1, collected by the DO detector at the Fermilab Tevatron ppˉp\bar{p} Collider at sqrt(s)=1.96 TeV. We use a constrained fit to reconstruct the kinematics of the ttˉt\bar{t} and decay products, which allows for the measurement of the leptonic decay angle θ\theta^* for each event. By comparing the cosθ\cos\theta^* distribution from the data with those for the expected background and signal for various values of f+, we find f+=0.00+-0.13(stat)+-0.07(syst). This measurement is consistent with the standard model prediction of f+=3.6x10^-4.Comment: Submitted to Physical Review D Rapid Communications 7 pages, 3 figure
    corecore